Lilliput LCD Fish/Depth Finder User Manual

LCD Fish/Depth Finder
User Manual
ZHANGZHOU LILLIPUT ELECTRONIC TECHNOLOGY CO., LTD
ADDRESS: Zong Si Road, Lan Tian Economic Development Zone,
Zhangzhou, Fu Jian, 363005, China
TEL0596-21093232109661 FAX0596-2109611
http://www.lilliput.com.cn & http://www.gdsun.com
Email:
sales@lilliput.com.cn
1
Dear Customer::
Thank you for choosing Lilliput’s LCD fish finder. This product adopts
high-performance embedded computer hardware. It is designed for operations under
relatively harsh marine environments and featuring water prove, damp prove,
corruption protection, wide voltage range protection etc. The delicately optimized
design meets the requirements of all users in its applications to various conditions and
occasions. Lilliput aims to server our customer with its excellent quality and exquisite
manufacturing technology.
We encourage you to read this installation and operations carefully in order to get full
benefit from all the features and application of this product.
Notice::
Do not power on the equipment when the transducer is expose to the air. It might
cause the damage to the transducer.
Install the transducer according to the instruction. Do not bend, twist, pull or press
the cable of the transducer.
The extension cable needs to put inside the seal terminal box. The cable of the
transducer is not allowed to touch the surface of the boat.
Once the equipment’s power has been put into the “on” position do not switch the
computer’s power to the “off” position until the computer is fully booted.
Please make sure that the power voltage setting has been adjusted to the standard
voltage value of the location where the product is being used.
Before using this product, please first make sure that all external wires and power
adapters have been correctly connected. If you suspect any defects, please contact
your sales agent or factory personnel immediately.
Dust, humidity and dramatic temperature changes will affect the usage life of this
computer. Please keep the machine away from these hazards.
In cleaning the units do not use chemical detergents. Remove dust with a soft
cloth to ensure brightness.
Warnings::
High Voltage Circuit! Disassembly and repair of device should only be performed by authorized service personal.
Power off the device from the plane immediately if there is water leaking into the equipment. Continuous using the equipment might causes short circuit. Please contact our service under those circumstances.
Do not attempt to modify or repair the original equipment. It may cause the damage of the precious electronic components inside the device.
Power off the device from the plane immediately if there is fire or smoke around. Continuous using the equipment might causes short circuit. Please contact our service under those circumstances
2
Contents
1. Introduction...............................................................................................3
2. Specification...............................................................................................3
2-1. Functions..........................................................................................3
2-2. Parameter..........................................................................................4
3. Installation..................................................................................................4
3-1. Installation Summary........................................................................4
3-2. Whole Device Installation…….........................................................5
3-3. Main Device Installation...................................................................6
3-4. Transducer Installation..................................................................... 6
3-5. Device Cable Interfaces………........................................................8
4..Display Windows......................................................................................9
4-1. Title Screen.......................................................................................9
4-2. Sonar View…………………………….....................…………..... 9
4-3. Sonar Zoom View…………………….....................………….......11
4-4. Dual Sonar View……………………….....................………….....12
4-5. Big Digital View…….………………….....................…………... 13
4-6. Circular View…………………………….....................…….…… 14
4-7. System Status…………………………….....................….……… 15
5. Key Button Functions............................................................................... 15
6. The Menu System...................................................................................... 17
6-1. Main MENU………………………………......................………. 17
6-2. Detailed MENU…………………………..….....................…...... 18
6-3. Brightness adjustment……………………..….....................…...... 21
7. RARAMETER........................................................................................... 21
8. STANDARD ACCESSORIES……………………..……..…………...... 22
3
1. Introduction
Your fishing system user interface is easy to use. A combination of menu, keys, different views, and situation-specific, customizable menus allows you to control the color on display. Refer to the following illustration, and see functions, views and menu systems for detail information.
1.4-WAY Cursor Control
2.MENU
3.VIEW
4.EXIT
5.POWER
6.Screen
2. Specification
2-1. Functions:
4.3” TFT LCD (resolution 480x320); Composed of multi-color multi-level waveform is more delicate; Manual adjustment range, the screen displays the waveform will not break; Automatic underwater range and automatic identification without manual intervention; pause screen brush map, move the cursor measurement of arbitrary target location; Any manually set the display range up and down range; User to adjust the screen split ratio; Data recording and playback High sensitivity gain and the gain in shallow water, clear bottom echo detection; Multiple alarm modes: depth, voltage, fish, temperature; Intelligent algorithm for more accurate identification of fish flesh, and a visual display; Setting display: contour, windows, real-time window, color, background color, light; A variety of protective measures: overvoltage, over current protection, reverse polarity
protection;
The whole machine adopts modular design, stability, reliability, default settings are not lost; Silicone flexible and reliable touch of a button, the new soft keyboard functionality allows
simple operation of complex functions.
2-2. Parameters:
1. Display, 4.3” color LCD, (resolution 480X320)
2. Sonar colors: standard (4 colors, 32 levels), gray, reverse, inverse, green etc
3. Display Mode: Standard, bottom zoom, dual displays, large numbers, graphics, version
information, simulation
4
4. Auto Mode: Auto range, auto sensitivity
5. Display waveforms: Anyway to set, display the waveform will not be interrupted
6. Interference suppression: automatic suppression of interference signals with frequency
unwanted signal Interference suppression
7. Cursor operation: for any point on the screen depth measurement
8. Depth migration: ±5m
9. Alarm mode: fish alarm, depth alarm, battery alarm, temperature alarm
10. Resolution: 0.022 m
11. Screen split: vertical
12. Frequency: 83/200KHZ dual
13. Depth range: 0 to 100 meters
14. Chart speed: 1 to 10
15. Background colors: white, blue, black
16. Output power: 300W
17. Power supplyDC 8.5V24V
18. Working Environment0 to 50
relative humidity below 95%
19. Storage Temperature20-70
20. Degree of protectionIP64
21. Weight: 960g
3. Installation
3-1. Installation Summary
Avoid direct sunrayavoid impact shock. The humidity and temperature condition of the install place should meet the
specifications.
The equipment should install in a well ventilated place, and keep away from the air pipe
and air vent.
Install the equipment in a sufficient room is recommended, therefore prepare enough
room for the cables and make it easy to carry out inspection and service.
Keep the equipment away from electromagnetic radiation device, such as motor and
generators.
5
3-2. Whole Device Installation
6
3-3 Main Device Installation
3-4..Transducer Installation:
Transducer is a precious front signal sensor. It must transport and install with care, no heavy pressure, fall off or working in the air. Painting and parasite should keep away from the surface of the transducer. The mounting location is very important and will affect the measure accuracy of the transducer directly. It is recommended to install it on the bilge where the surface is smooth and flat. Keep the transducer far away from propeller or pipelines which generate turbulent water. Keep the surface of the transducer horizontal, use guide plate to guarantee gentle water flows if the bilge is not flat. Do not expose the transducer into the air under any circumstances. Mark and drill mounting holes: