Lightolier MINI-BEAM-MB, PARAPLUS-PP User Manual

Lightolier
45 INDUSTRIAL WAY, WILMINGTON, MA 01887
PARAPLUS (PP), COFFAIRE (CF), MINI-BEAM (MB), HP90 (H9)
INSTALLATION INSTRUCTIONS
IMPORTANT: For Paraplus remove the Louver
1
before installing fixture into ceiling system (by others). To remove the Louver, depress one side of the Louver to clear the Hinge Pin and
Housing
Overlay
Louver
Hinge Pin
2
Access Plate for CF/PP
Hinge Pin
Remove Access Plate (snaps in and out of position). Bend Housing Tab up to attach ground screw to green screw on the Housing Tab. Then bend Housing Tab down into the Housing as shown. Install Access Plate.
pull the Louver towards you. Rotate the Louver upwards and remove from the Hinge Pins on the opposite side of the Housing.
Louver
Louver
Housing
Hinge Pin
Access Plate
Housing
Access Plate for Mini-Beam (MB).
3
Remove Access Plate by sliding Access Plate in the direction of Arrow 1. To remove, lift up and slide in the direction of Arrow 2. Bend Housing Tab up out of Housing and make ground and ballast connections. Bend Housing Tab back to original position. Replace the Access Plate by reversing removal procedure.
Access Plate Opening
Housing Tab
Access
1.
Plate
2.
Tab
Access Plate Opening
Access Plate Opening
Ground Screw
Fixture Tab
© a Genlyte company
59-31115-003 Printed in U.S.A.
To install fixture into the ceiling system (by
4
others), bend Earthquake Clips out 90 degress from Housing End. Install fixture into ceiling system. Secure the fixture to the ceiling system by bending the Locking Tabs on the Earthquake Clips towards the T-bar.
Housing
Install fixture into Ceiling System (by others).
5
For Coffaire (CF) and Mini-Beam (MB), open Lamp Shield by gripping Narrow Flange of Lamp Shield and pull Lamp Shield towards you, letting the opposite side of the Lamp Shield rest on the Hinge Pins (Wide Flange).
Earthquake Clip
Locking Tab
Housing
T-bar (by others)
Locking Tab
Earthquake Clip
T-bar (by others)
Earthquake Clip
Locking Tab
Coffaire Mini-Beam
Ceiling System (by others)
COFFAIRE (CF) MINI-BEAM (MB)
Hinge Pin (Wide Flange)
Hinge Pin (Narrow Flange)
Lamp Shield
For Mini-Beam Ballast Access Cover
6
Compartment.
Ballast is accessed by removing the ceiling tile adjacent to the Mini-Beam. Remove Screw at end of Ballast Access Cover and slide Ballast Access Cover towards Housing End. Lift Ballast Access Cover for easy access to Ballast. To replace Ballast Access Cover reverse the procedure.
Hinge Pin
Lens
HP90 Lens Removal
Push Lens to one side A , and pull Lens off Hinge Pins B and downward. Unlink Lens from
O
O
all Hinge Pins (both ends of fixture) clearing the lamps for removal.
A
O
B
O
Ballast Access Cover
Screw