Lightolier MBS2GPW224 User Manual

Mini-Beam 2' x 2' Recessed Fluorescent MBS2GPW224
Page 1 of 2 Direct/Indirect, Static, 2 Lamp, Linear T5, 24 Watt
Features
Direct/indirect lamp shield appearance with soft contoured interior.
• Four inch wide perforated mesh lamp shield with white acrylic overlay.
• 62.3% efficient.
• Only 5-1/2" deep.
• Same fixture fits both G and T ceiling types.
• Fits flush to face of slot grid (T) ceiling types.
• Lamp shield hinges from either side.
• Hinged external ballast housing compartment.
• Can be continuous row mounted.
• Wiring access plate standard.
• 4 hold-down clips standard.
• Housing is 20 gauge steel, meets NYC Code requirements.
• Optional DALI ballast accepts digital dimming commands from computers, scene controllers and automatic control devices.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2004 Lightolier Section 5/Folio M20-10
3/04
Hinged external ballast housing compartment
Exposed t-grid ceiling
Exposed slot t-grid ceiling
Acoustical material by others
Exposed T-bar by others
1-1/2" max.
Acoustical material by others
15/16"
24"
1-7/8" max.
Exposed T-bar by others
9/16"
24"
Hold-down clips
Mounting Methods Dimensions
Hinged external ballast housing compartment
Ballast
2" x 2" access plate with two K.O.’s (7/8" dia.)
3-1/2"
(89mm)
24" (610mm)
Features
Hinged external ballast housing compartment
24" (610mm)
5-1/2"
(139mm)
4" (102mm)
Mini-Beam 2' x 2' Recessed Fluorescent MBS2GPW224
Page 2 of 2 Direct/Indirect, Static, 2 Lamp, Linear T5, 24 Watt
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2004 Lightolier Section5/Folio M20-10
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: MBS2GPW224120PGGLR
Options/Accessories
Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Electrical/Wiring Options: Consult factory.
Specifications
Performance: In an installation of 2 lamp 24W luminaires in a room cavity of 1,
with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .65. To reduce glare the average brightness at 65° shall not exceed 2725 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 75.8%.
Materials: Housing is die-formed 20 gauge steel. Finish: Chassis exterior–baked white acrylic enamel. Reflector–baked flat
white acrylic enamel, minimum 86% reflectance. Phosphate undercoating.
Lamp Shield–baked flat white acrylic enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Photometry
Model No. MBS2GPW224120PG
MB
Mini-Beam
Direct/Indirect
Recessed
with Perforated
Mesh Shield
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
P
Perforated
Lamp Shield
W
White
Reflector
Voltage:
120 or 277
Options:
Add appropriate suffix to catalog
no, ie: (GLR)
Ballast:
PI = Linear T5
Instant Start Less than 10 THD
PG = Programmed
Start Less than 10 THD
DA = DALI digital
addressable dimming
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1686562 615957 585755 2625652 535047 514846 3565044 474339 454239 4514438 413733 403633 5473833 363228 353128 6433429 322824 312724 7393125 292421 282421 8362722 262118 252118 9332519 231915 231815
10 31 22 17 21 17 14 21 16 13
visual comfort probability
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 64 71 82 91 54 62 76 88
20 30 60 64 72 81 47 52 60 73 20 40 59 62 67 73 45 48 53 61 20 60 59 61 64 69 43 46 48 54
30 20 62 69 79 88 56 63 75 86 30 30 58 62 68 77 49 53 59 71 30 40 57 59 63 69 46 48 52 59 30 60 57 58 60 65 44 46 47 51 30 80 57 59 59 63 43 45 45 49
40 20 63 69 77 86 59 65 75 85 40 30 59 61 67 75 52 55 60 71 40 40 57 59 61 67 48 50 52 58 40 60 57 57 58 62 45 47 47 51 40 80 57 58 57 61 45 46 44 48 40 100 58 58 57 60 45 45 44 46
60 30 59 62 66 73 54 57 61 70 60 40 58 59 60 65 50 52 53 59 60 60 57 57 57 60 47 48 47 51 60 80 57 57 56 58 46 46 45 47 60 100 58 58 56 58 46 46 43 45
100 40 60 61 61 66 56 56 56 61 100 60 59 59 57 60 52 52 50 53 100 80 59 58 56 58 50 50 47 49 100 100 60 59 56 57 49 49 46 47
room cavity ratio
luminaries lengthwise
luminaries crosswise
LER = FL - 41.9 IW - 52.0 BF - 1.00 Comparative yearly lighting energy cost per 1000 lumens = $5.72
S
Body Style:
S = Static
2
Lamp
Quantity
24
Lamp Quantity:
(By others)
24 = HO/T5 24 Watt
For Local 3 Manufacturing, substitute for . Example: MNS2GPW224120PGGLR .
MN
MN
For Local 3
Manufacturing
MB