Mini-Beam 2' x 2' Recessed Fluorescent MBS2GPW224
Page 2 of 2 Direct/Indirect, Static, 2 Lamp, Linear T5, 24 Watt
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
Copyright 2004 Lightolier Section5/Folio M20-10
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: MBS2GPW224120PGGLR
Options/Accessories
Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Electrical/Wiring Options: Consult factory.
Specifications
Performance: In an installation of 2 lamp 24W luminaires in a room cavity of 1,
with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less
than .65. To reduce glare the average brightness at 65° shall not exceed 2725
candelas per square meter. To control veiling reflections, luminaire output in the
30°-90° zone shall not be less than 75.8%.
Materials: Housing is die-formed 20 gauge steel.
Finish: Chassis exterior–baked white acrylic enamel. Reflector–baked flat
white acrylic enamel, minimum 86% reflectance. Phosphate undercoating.
Lamp Shield–baked flat white acrylic enamel.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Photometry
Model No. MBS2GPW224120PG
MB
Mini-Beam
Direct/Indirect
Recessed
with Perforated
Mesh Shield
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
P
Perforated
Lamp Shield
W
White
Reflector
Voltage:
120 or 277
Options:
Add appropriate
suffix to catalog
no, ie: (GLR)
Ballast:
PI = Linear T5
Instant Start
Less than 10 THD
PG = Programmed
Start
Less than 10 THD
DA = DALI digital
addressable
dimming
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1686562 615957 585755
2625652 535047 514846
3565044 474339 454239
4514438 413733 403633
5473833 363228 353128
6433429 322824 312724
7393125 292421 282421
8362722 262118 252118
9332519 231915 231815
10 31 22 17 21 17 14 21 16 13
visual comfort probability
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 64 71 82 91 54 62 76 88
20 30 60 64 72 81 47 52 60 73
20 40 59 62 67 73 45 48 53 61
20 60 59 61 64 69 43 46 48 54
30 20 62 69 79 88 56 63 75 86
30 30 58 62 68 77 49 53 59 71
30 40 57 59 63 69 46 48 52 59
30 60 57 58 60 65 44 46 47 51
30 80 57 59 59 63 43 45 45 49
40 20 63 69 77 86 59 65 75 85
40 30 59 61 67 75 52 55 60 71
40 40 57 59 61 67 48 50 52 58
40 60 57 57 58 62 45 47 47 51
40 80 57 58 57 61 45 46 44 48
40 100 58 58 57 60 45 45 44 46
60 30 59 62 66 73 54 57 61 70
60 40 58 59 60 65 50 52 53 59
60 60 57 57 57 60 47 48 47 51
60 80 57 57 56 58 46 46 45 47
60 100 58 58 56 58 46 46 43 45
100 40 60 61 61 66 56 56 56 61
100 60 59 59 57 60 52 52 50 53
100 80 59 58 56 58 50 50 47 49
100 100 60 59 56 57 49 49 46 47
room cavity ratio
luminaries lengthwise
luminaries crosswise
LER = FL - 41.9 IW - 52.0 BF - 1.00
Comparative yearly lighting energy cost per 1000 lumens = $5.72
S
Body Style:
S = Static
2
Lamp
Quantity
24
Lamp Quantity:
(By others)
24 = HO/T5 24 Watt
For Local 3 Manufacturing, substitute for . Example: MNS2GPW224120PGGLR .
MN
MN
For Local 3
Manufacturing
MB