Lightolier C3MRGD User Manual

Calculite
Spec. Sheet
C3MRGD
1/2"
(13mm)
2" (59mm) Max.
Ceiling Thk.
2 3/4" (70mm) Dia.
4" (102mm) Dia.
C3LV
Vertical Adjustment
1" (25mm) to
2 3/4" (70mm)
9 1/2"
(242mm)
9"
(229mm)
1/2" (13mm)
C3AICLV
10 412 3 6 7 9 85
5 1/2"
(140mm)
5"
(127mm)
Plus Ceiling
Thk.
5" (127mm)
12 5/8"
(321mm)
14 3/8"
(365mm)
9 5/8"
(245mm)
5" (127mm)
14 3/8"
(365mm)
10 1/8"
(257mm)
9" (229mm)
22 3/8"
(568mm)
14 5/8"
(372mm)
®
Evolution Glasslite Downlight C3MRGD
Page 1 of 2 3" Aperture, MR16 (12V)
Non-IC Frame: C3LV C3LVE1 C3LVE2
Non-IC AirSeal Frame: C3ALV C3ALVE1 C3ALVE2
IC AirSeal Frame: C3AICLV C3ALCLVE1
Ceiling Cutout: 3 1/2" (130mm) Dia. For Complete Fixture Order: Trim Kit + Frame-In Kit. Each Sold Separately.
Trim Kit Frame-In Kit Lamp*
C3LV Non-IC Magnetic 120/277V 42W-65W MR16 (12V) C3LVE1 Non-IC Electronic 120V 20W-65W MR16 (12V) C3LVE2 Non-IC Electronic 277V 20W-65W MR16 (12V)
Etch White Glasslite C3MRGD
C3ALV Non-IC AirSeal® Magnetic 120/277V 42W-65W MR16 (12V) C3ALVE1 Non-IC AirSeal® Electronic 120V 20W-65W MR16 (12V) C3ALVE2 Non-IC AirSeal® Electronic 277V 20W-65W MR16 (12V) C3AICLV IC AirSeal® Magnetic 120V 20W-50W MR16 (12V) C3AICLVE1 IC AirSeal® Electronic 120V 20W-50W MR16 (12V) Note: Magnetic not recommended for residential or noise sensitive areas.
Features
1. Glasslite: One piece borosilicate glass with interal flange, etched interior
and white ceramic coated exterior. Etched white cone finish emits a subtie glow. Hinged, and snaps on for easy tool-less installation. Interchangeable with other 3" Evolution trims. Suitable for shower and other wet environments.
2. Lamp Support: Die-form aluminum with knurled surface for easy gripping
during relamping. Spring tension clips hold lamp and lens and allow fast snap-in, snap-out relamping. Matte black finish. Accepts up to two 2" diameter accessories.
3. Cover Glass: High temperature, clear lens.
4. Thick Ceiling Ready Brackets: Die-form steel, matte black finish. Adjust
trim kit vertically to accommodate up to 2" thick ceiling, lockable.
5. Lampholder: Procelain bi-pin socket. Pre-wired with No.18 AWG Teflon leads.
6. Horizontal Adjustment Mechanism: Built-in ready for adjustable trim, matte
black finish.
7. Frame Vertical Adjustment Mechanism (C3LV): Accommodates mounting
to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking features secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below inside fixture.
8. Mounting Bars (C3LV): Galvanized steel, 0.048"; pre-installed telescoping
bars extend from 20" to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplified installation in 24"O.C. grid systems. Attaches to steel or wood joists without accessories.
9. Transformer: Replaceable from below. Magnetic: 120V/277V 60 Hz. dual-
sensitive areas. Electronic: 120V or 277V 50/60 Hz., regulated lamp voltage, HPF, , EMI and circuit protections, thermal auto-reset, quiet operation.
10. Frame-In Kit: See Frame-In Kit specification sheets for more information.
Non-IC and Non-IC AirSeal - Insulation must be kept 3"away from any parts of
voltage, core & coil. Note: Magnetic not recommended for residential or noise
the luminaire and must not be placed above luminaire in a manner which will entrap heat. IC AirSeal - Luminaire may be in direct contact with thermal insulation.
Labels
U.L. (Suitable For Wet Locations), I.B.E.W.; U.S. & Foreign Patents Pending *Lamp wattage restriction for Non-IC: 65W for up to 1" thick ceiling, 50W
for ceiling thickness greater than 1" (up to 2").
Options and Accessories
2" dia. Color Filters/Specialty filters: See ADF2/AF2 specification sheets 2" dia. Louver: AL2HC Chicago Plenum: Consult Factory
Job Information Type:
Job Name:
Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC • D1107
Calculite
Spec. Sheet
C3MRGD
®
Evolution Glasslite Downlight C3MRGD
Page 2 of 2 3" Aperture, MR16 (12V)
50W MR16 - 15° SPOT GE HALOGEN LAMP, LUMEN RATING = 750 LMS, 120V ELECTRONIC TRANSFORMER
CANDLEPOWER DISTRIBUTION
1400˚
2800˚
4200˚
5600˚
** EFFICIENCY = 69.7% ** CERTIFIED TEST REPORT NO. 2724FR DATE: SEP 7, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**
SC = .2
50W MR16 - 25° NARROW FLOOD GE HALOGEN LAMP, LUMEN RATING = 800 LMS, 120V ELECTRONIC TRANSFORMER
CANDLEPOWER DISTRIBUTION
500˚
1000˚
1500˚
2000˚
** EFFICIENCY = 65.1% ** CERTIFIED TEST REPORT NO. 2817FR DATE: SEP 5, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**
SC = .5
ANGLE MEAN CP LUMENS 0 5551 5 3854 345 10 1184
60˚
15 310 138 20 141 25 48 30 30 22 35 8 7 40 5 45 2 2 50 1 55 2 1 60 1 65 0 0 70 0 75 0 0 80 0 85 0 0
30˚
90 0
ANGLE MEAN CP LUMENS 0 1816 5 1629 150 10 1213
60˚
15 792 231 20 460 25 194 107 30 74 35 27 21 40 8 45 5 4 50 4 55 3 3 60 3 65 2 2 70 2 75 1 1 80 1
30˚
85 0 0 90 0
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M 45 640 55 750 65 104 75 170 85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 512 68.32 97.99 0-40 518 66.20 99.25 0-60 522 69.64 99.89 0-90 522 69.72 100.00 40-90 3 0.52 0.75 60-90 0 0.08 0.11 90-180 0 0.00 0.00 0-180 522 69.72 100.00
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M 45 1483 55 1270 65 1241 75 1079 85 351
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 487 60.97 93.72 0-40 509 63.64 97.83 0-60 516 64.55 99.23 0-90 520 65.05 100.00 40-90 11 1.41 2.17 60-90 4 0.50 0.77 90-180 0 0.00 0.00 0-180 520 65.05 100.00
Coefficients of Utilization
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0 RCR
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
0 .83 .83 .83 .83 .81 .81 .77 .77 .74 .74 .70 1 .81 .80 .79 .78 .79 .77 .76 .75 .73 .73 .69 2 .79 .79 .76 .75 .76 .74 .74 .73 .73 .71 .69 3 .78 .76 .74 .73 .75 .72 .73 .71 .72 .70 .68 4 .77 .74 .72 .71 .74 .70 .72 .70 .71 .69 .68 5 .75 .73 .71 .69 .72 .69 .71 .69 .70 .68 .67 6 .74 .72 .70 .68 .71 .68 .70 .68 .70 .67 .66 7 .73 .71 .69 .67 .70 .67 .69 .67 .69 .66 .66 8 .73 .70 .68 .67 .69 .66 .69 .66 .68 .66 .65 9 .72 .69 .67 .66 .68 .66 .68 .65 .68 .65 .65 10 .71 .68 .66 .65 .68 .65 .67 .65 .67 .65 .64
LUMINAIRE INPUT WATTS = 51
Coefficients of Utilization
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0 RCR
LUMINAIRE INPUT WATTS = 51
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
0 .77 .77 .77 .77 .76 .76 .72 .72 .69 .69 .65 1 .75 .74 .73 .72 .73 .71 .70 .69 .68 .67 .64 2 .73 .71 .70 .68 .70 .67 .68 .66 .66 .64 .62 3 .71 .69 .67 .65 .68 .65 .66 .64 .65 .63 .61 4 .70 .67 .64 .63 .66 .62 .65 .62 .64 .61 .60 5 .68 .65 .62 .60 .64 .60 .63 .60 .62 .59 .58 6 .66 .63 .61 .59 .62 .59 .62 .58 .61 .58 .57 7 .65 .61 .59 .57 .61 .57 .60 .57 .59 .56 .56 8 .63 .60 .57 .56 .59 .56 .59 .55 .58 .55 .54 9 .62 .58 .56 .54 .58 .54 .57 .54 .57 .54 .53 10 .61 .57 .55 .53 .57 .53 .56 .53 .56 .53 .52
50W MR16 - 40° FLOOD GE HALOGEN LAMP, LUMEN RATING = 800 LMS, 120V ELECTRONIC TRANSFORMER
CANDLEPOWER DISTRIBUTION
375˚
750˚
1125˚
1500˚
** EFFICIENCY = 68% ** CERTIFIED TEST REPORT NO. 2722FR DATE: SEP 5, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**
SC = .6
ANGLE MEAN CP LUMENS 0 1425 5 1388 130 10 1256
60˚
15 1006 275 20 616 25 182 118 30 42 35 17 13 40 8 45 4 3 50 3 55 2 2 60 2 65 1 1 70 0 75 0 0 80 0 85 0 0
30˚
90 0
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M 45 1164 55 864 65 616 75 0 85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 523 65.48 96.34 0-40 537 67.14 98.77 0-60 542 67.82 98.77 0-90 543 67.97 100.00 40-90 6 0.83 1.23 60-90 1 0.16 0.23 90-180 0 0.00 0.00 0-180 543 67.97 100.00
Coefficients of Utilization
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0 RCR
LUMINAIRE INPUT WATTS = 51
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
0 .81 .81 .81 .81 .79 .79 .76 .76 .72 .72 .66 1 .79 .78 .77 .75 .76 .74 .73 .72 .71 .70 .67 2 .76 .75 .73. 71 .73 .71 .71 .69 .69 .68 .65 3 .75 .72 .70 .68 .71 .68 .70 .67 .68 .66 .64 4 .73 .70 .68 .66 .69 .66 .68 .65 .67 .64 .63 5 .71 .68 .65 .64 .67 .63 .66 .63 .65 .62 .61 6 .70 .66 .64 .62 .66 .62 .65 .62 .64 .61 .60 7 .68 .64 .62 .60 .64 .60 .63 .60 .63 .60 .59 8 .67 .63 .60 .59 .62 .59 .62 .58 .61 .58 .57 9 .65 .61 .59 .57 .61 .57 .60 .57 .60 .57 .56 10 .64 .60 .58 .56 .60 .56 .59 .56 .59 .56 .55
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC • D1107