Lighting Systems Baselyte-BSL1 |
Page of 8 |
2 Light T8 Direct/Indirect |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Weight = 3.0 lb./ft |
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Ordering Information |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Family |
Distribution |
|
Lamp Type |
|
|
No. of Lamps |
Housing |
Module Length |
|
Wiring |
Voltage |
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BSL |
|
|
6 |
|
|
T |
|
|
|
02 |
|
|
CN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 = Direct/ |
|
T = T8 |
|
|
02 = 2 Light |
|
CN = Cutout |
|
04 = 4’ |
|
1 = 1cct. |
|
1 = 120V |
||||||||||
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
|
|
|
Indirect |
|
|
|
|
|
|
|
|
w/baffles |
|
08 = 8’ |
2 = 2cct. |
2 = 277V |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12 = 12’ |
3 = 1cct. w/EC/NL |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
= 2cct. w/EC/NL |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
= 1cct. w/EM Battery |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 |
= 2cct. w/EM Battery |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
= 1cct. w/Dimming |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8 |
= 1cct. w/1cct. |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Thru wire |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 |
= 2cct. w/1cct. |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Thru wire |
|
Note: Please consult wiring section of spec sheets for more wiring options.
|
|
Ballast |
Finish |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
E = Standard |
|
C = Custom Color |
|||
|
|
|||||
|
|
<20% THD |
W = Standard |
|||
|
F = Standard |
White |
||||
|
|
<20% THD |
|
|
||
|
|
w/fusing |
|
|
||
|
G = <10% THD, |
|
|
|||
|
|
Instant Start |
|
|
||
|
H = <10% THD, |
|
|
|||
|
|
Instant Start |
|
|
||
|
|
w/fusing |
|
|
||
|
J = <10% THD, |
|
|
|||
|
|
Program Start |
|
|
||
|
K = <10% THD, |
|
|
|||
|
|
Program Start |
|
|
||
|
|
w/fusing |
|
|
Specifications
Features
1.Housing: die-formed 20ga. cold rolled steel
2.End Set: die-cast metal with baked powder coat finish
3.Lamping: two T8 lamps
4.Configuration: 4’, 8’ and 12’ module lengths or continuous rows
5.Ballasts: electronic 120V or 277V
Finish
High-quality white powder coat with textured matte finish.
Custom colors available. Consult factory.
Mounting
Aircraft cable gripper is tamper-resistant and provides infinite vertical adjustment capability. Aircraft cable, crimp and cable gripper independently tested to meet stringent safety requirements.
Electrical
All luminaires are factory pre-wired to module ends with quick-wire connectors.
Joints & Intersections
Self-aligning joining system with hands-free pre-joining wire access.
Labels
UL, CSA standards.
Ordering Instructions
Individual Fixtures
1.Determine the number of individual modules required
2.Order one end set per module
3.Order one non-power mount per module
4.Order one power mount per module
Continuous Rows*
1.Determine run length
2.Order the appropriate number and length of modules for complete run
3.Order one end set for each run
4.Order one non-power mount for each module
5.Order one power mount per run
6.Order one joiner per module minus one (e.g. 3 modules requires 2 joiners)
*Note: Some runs may require additional power mounts. Please see the ‘Run Configuration’ table on next page for more details.
|
|
|
|
|
Job Information |
Type: |
|
|
|
|
|
|||
|
|
|||
|
|
|
|
|
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Company www.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Lighting Systems Baselyte-BSL1
Page |
|
of 8 |
|
|
|
|
|
|
|
|||
Performance |
|
|
|
|
|
|
|
|||||
Candlepower Curve |
Candlepower Summary |
|
|
|
||||||||
|
|
|
|
|
ZONE |
|
CANDLEPOWER |
|
||||
|
|
|
|
|||||||||
|
|
|
|
|
DEG. |
0 |
22.5 |
45 |
67.5 |
90 |
||
|
|
|
|
|
|
|||||||
|
|
|
||||||||||
|
|
|
|
|
|
180 |
1045 |
1045 |
1045 |
1045 |
1045 |
|
|
|
|
|
|
175 |
1040 |
1038 |
1038 |
1035 |
1037 |
||
|
|
|
|
165 |
1001 |
994 |
1000 |
1003 |
1006 |
|||
|
|
|
|
155 |
931 |
922 |
942 |
949 |
957 |
|||
|
|
|
|
145 |
831 |
826 |
863 |
906 |
925 |
|||
|
|
|
135 |
693 |
705 |
788 |
855 |
884 |
||||
|
|
|
|
|
125 |
544 |
569 |
700 |
795 |
827 |
||
|
|
|
|
|||||||||
|
|
|
|
115 |
376 |
434 |
596 |
673 |
706 |
|||
|
|
105 |
205 |
299 |
448 |
501 |
545 |
|||||
|
|
|
|
|
||||||||
|
|
|
|
95 |
48 |
117 |
187 |
172 |
214 |
|||
|
|
|
|
90 |
5 |
20 |
35 |
42 |
47 |
|||
|
|
|
|
|
||||||||
|
|
|
|
85 |
15 |
26 |
42 |
48 |
51 |
|||
|
|
|
|
|
||||||||
|
|
|
|
75 |
43 |
46 |
55 |
68 |
73 |
|||
|
|
|
|
|
||||||||
|
|
|
|
|
65 |
86 |
99 |
86 |
72 |
76 |
||
|
|
|||||||||||
|
|
|
|
55 |
185 |
163 |
155 |
131 |
128 |
|||
|
|
|||||||||||
Report No: 2101580 |
45 |
300 |
249 |
227 |
212 |
212 |
||||||
35 |
412 |
354 |
314 |
281 |
286 |
|||||||
Lamps: F32T8 |
||||||||||||
25 |
515 |
463 |
437 |
384 |
384 |
|||||||
Lumens per Lamp: 2950 |
15 |
598 |
567 |
548 |
515 |
516 |
||||||
Efficiency: 82.1% |
5 |
646 |
637 |
636 |
619 |
623 |
||||||
Up: 76.9% Down: 23.1% |
0 |
651 |
651 |
651 |
651 |
651 |
Module Lengths & Mounting Distances
@
-ODULE ,ENGTH , -OUNTING $ISTANCE
@
-ODULE ,ENGTH ,-OUNTING $ISTANCE
@
-ODULE ,ENGTH ,-OUNTING $ISTANCE
Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).
2 Light T8 Direct/Indirect
Coefficients of Utilization
|
|
% EFFECTIVE CEILING CAVITY REFLECTANCE |
|
|||||||
|
|
80 |
|
|
70 |
|
|
|
50 |
|
|
|
|
|
% WALL REFLECTANCE |
|
|
|
|||
|
50 |
30 |
10 |
50 |
30 |
10 |
|
50 |
30 |
10 |
0 |
82 |
82 |
82 |
73 |
73 |
73 |
|
56 |
56 |
56 |
1 |
72 |
69 |
66 |
64 |
61 |
59 |
|
49 |
47 |
46 |
2 |
63 |
58 |
54 |
56 |
52 |
49 |
|
43 |
40 |
38 |
3 |
55 |
50 |
45 |
49 |
45 |
41 |
|
38 |
35 |
32 |
4 |
49 |
43 |
38 |
44 |
39 |
35 |
|
34 |
30 |
27 |
5 |
44 |
37 |
33 |
39 |
34 |
30 |
|
30 |
26 |
24 |
6 |
39 |
33 |
28 |
35 |
30 |
26 |
|
27 |
23 |
21 |
7 |
35 |
29 |
25 |
31 |
26 |
22 |
|
25 |
21 |
18 |
8 |
32 |
26 |
22 |
29 |
23 |
20 |
|
22 |
19 |
16 |
9 |
29 |
23 |
19 |
26 |
21 |
18 |
|
20 |
17 |
14 |
10 |
26 |
21 |
17 |
24 |
19 |
16 |
|
19 |
15 |
13 |
Zonal Lumen Summary |
|
||
ZONE |
LUMENS |
%BARE LAMP |
%LUMINAIRE |
0-90 |
1117 |
18.9 |
23.1 |
90-180 |
3728 |
63.2 |
76.9 |
0-180 |
4845 |
82.1 |
100.0 |
Run Configuration
Run |
4’ |
8’ |
12’ |
Joiner |
End Set |
Mount |
Power |
|
|
|
Length |
Module |
Module |
Module |
Mount* |
|
|
|
|||
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
4’ run |
1 |
|
|
|
1 |
1 |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8’ run |
|
1 |
|
|
1 |
1 |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12’ run |
|
|
1 |
|
1 |
1 |
1 |
|
|
|
16’ run |
|
2 |
|
1 |
1 |
2 |
1 |
|
|
|
|
|
|
|
|||||||
20’ run |
|
1 |
1 |
1 |
1 |
2 |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
24’ run |
|
|
2 |
1 |
1 |
2 |
1 |
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
28’ run |
|
2 |
1 |
2 |
1 |
3 |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
32’ run |
|
1 |
2 |
2 |
1 |
3 |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.
System Components & Accessories
End Set
BSLESW = suspended standard white
Joiner |
BSLJS = suspended joiner
Dust Cover
BSLDCS = 4’ suspended dust cover
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Job Information |
Type: |
|
|
|
|
|
|
Lightolier a Genlyte Company |
www.lightolier.com |
|
|
|
|
|
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
|
Lighting Systems Baselyte-BSL1 |
Page of 8 |
2 Light T8 Direct/Indirect |
Mounting Options
Mount Type: T-Bar 15/16” (On-Grid)*
•65 lbs maximum load
•Canopy: Diameter of 3 3/4“x 7/32”
•Cable: 7x7 stranded aircraft cable
•Supported by T-bar and secured to structure
•J-Box: 4” square (supplied by others)
•Fully adjustable vertically at fixture
1-Power Mount Non-Power Mount
|
|
Supension Length |
|
|
1-Power Mount |
|
|
|
|
2’ |
4’ |
8’ |
12’ |
|
|
|
|
|
|
3 Conductor |
BSLM6102P13 |
BSLM6104P13 |
BSLM6108P13 |
BSLM6112P13 |
|
|
|
|
|
4 Conductor |
BSLM6102P14 |
BSLM6104P14 |
BSLM6108P14 |
BSLM6112P14 |
|
|
|
|
|
7 Conductor |
BSLM6102P17 |
BSLM6104P17 |
BSLM6108P17 |
BSLM6112P17 |
Non-Power Mount |
|
|
|
|
|
|
|
|
|
BSLM6102N |
BSLM6104N |
BSLM6108N |
BSLM6112N |
|
|
|
|
|
|
Mount Type: T-Bar 9/16” (On-Grid)*
•65 lbs maximum load
•Canopy: Diameter of 3 3/4“x 7/32”
•Cable: 7x7 stranded aircraft cable
•Supported by T-bar and secured to structure
•J-Box: 4” square (supplied by others)
•Fully adjustable vertically at fixture
1-Power Mount Non-Power Mount
|
|
Supension Length |
|
|
|
|
|
1-Power Mount |
|
|
|
|
|
|
|
2’ |
4’ |
8’ |
12’ |
|
|
|
|
|
|
|
|
|
|
|
|
3 Conductor |
BSLM6202P13 |
BSLM6204P13 |
BSLM6208P13 |
BSLM6212P13 |
|
|
|
|
|
|
|
|
|
|
|
4 Conductor |
BSLM6202P14 |
BSLM6204P14 |
BSLM6208P14 |
BSLM6212P14 |
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
7 Conductor |
BSLM6202P17 |
BSLM6204P17 |
BSLM6208P17 |
BSLM6212P17 |
|
|
|
Non-Power Mount |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BSLM6202N |
BSLM6204N |
BSLM6208N |
BSLM6212N |
|
|
|
|
|
|
|
|
|
|
|
|
Mount Type: T-Bar 9/16” by 5/16” Slot Grid (On-Grid)*
•65 lbs maximum load
•Canopy: Diameter of 3 3/4“x 7/32”
•Cable: 7x7 stranded aircraft cable
•Supported by T-bar and secured to structure
•J-Box: 4” square (supplied by others)
•Fully adjustable vertically at fixture
*Note: Standard T-bar mounts are currently not available for tegular tile ceilings, however certain tegular tile / T-bar combinations may be supported by the use of the slot-grid mount. For more information, please consult factory.
1-Power Mount Non-Power Mount
|
|
|
|
Supension Length |
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|||
1-Power Mount |
|
|
|
|
|
|
|
|||||||
2’ |
|
4’ |
8’ |
12’ |
|
|
||||||||
|
|
|
|
|
|
|
||||||||
3 Conductor |
BSLM6302P13 |
BSLM6304P13 |
BSLM6308P13 |
BSLM6312P13 |
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
||||||||
4 Conductor |
BSLM6302P14 |
BSLM6304P14 |
BSLM6308P14 |
BSLM6312P14 |
|
|
|
|
|
|
||||
7 Conductor |
BSLM6302P17 |
BSLM6304P17 |
BSLM6308P17 |
BSLM6312P17 |
|
|
|
|
|
|
||||
|
|
|
|
|
||||||||||
|
|
|
|
|
||||||||||
Non-Power Mount |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|||||
BSLM6302N |
BSLM6304N |
BSLM6308N |
BSLM6312N |
|
|
|
|
|||||||
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Job Information |
|
Type: |
|
|
|
|
|
|
|
|
|||
|
Lightolier a Genlyte Company |
|
|
www.lightolier.com |
|
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1