Calculite
5" (127mm)
12 5/8"
(321mm)
14 3/8"
(365mm)
9 5/8"
(245mm)
5" (127mm)
14 3/8"
(365mm)
10 1/8"
(257mm)
9" (229mm)
22 3/8"
(568mm)
14 5/8"
(372mm)
Spec. Sheet
C3MRD
"FRAMING"
5 1/2"
(140mm)
5"
(127mm)
Plus Ceiling
Thk.
1/2"
(13mm)
2" (59mm) Max.
Ceiling Thk.
3" (76mm) Dia.
4" (102mm) Dia.
Flangeless Trim with
Plaster Ring Accessory
C3LV
9 1/2"
(242mm)
9"
(229mm)
1/2" (13mm)
C3AICLV
Vertical Adjustment
1" (25mm) to
2 3/4" (70mm)
3 3/8" (86mm) Dia.
10 412 3 6 7 9 85
®
Evolution Open Reflector Downlight C3MRD
Page 1 of 2 3" Aperture, MR16 (12V)
Non-IC Frame:
C3LV
C3LVE1
C3LVE2
Non-IC AirSeal Frame:
C3ALV
C3ALVE1
C3ALVE2
IC AirSeal Frame:
C3AICLV
C3ALCLVE1
Ceiling Cutout: 3 1/2" (130mm) Dia.
For Complete Fixture Order: Trim Kit + Frame-In Kit. Each Sold Separately.
Trim Kit Frame-In Kit Lamp*
Cone Finish
Clear C3MRD CLW C3MRD CLP C3MRD CLFT
Comfort Clear Diffuse C3MRD CCDW C3MRD CCDP C3MRD CCDFT
Champagne Bronze C3MRD CCZW C3MRD CCZP C3MRD CCZFT
Gold C3MRD GDW C3MRD GDP C3MRD GDFT
Matte White C3MRD WHW N/A C3MRD WHFT
Specular Black C3MRD BKW C3MRD BKP C3MRD BKFT
White Flange Polished Flange Flangeless
C3LV Non-IC Magnetic 120/277V 42W-65W MR16 (12V)
C3LVE1 Non-IC Electronic 120V 20W-65W MR16 (12V)
C3LVE2 Non-IC Electronic 277V 20W-65W MR16 (12V)
C3ALV Non-IC AirSeal® Magnetic 120/277V 42W-65W MR16 (12V)
C3ALVE1 Non-IC AirSeal® Electronic 120V 20W-65W MR16 (12V)
C3ALVE2 Non-IC AirSeal® Electronic 277V 20W-65W MR16 (12V)
C3AICLV IC AirSeal® Magnetic 120V 20W-50W MR16 (12V)
C3AICLVE1 IC AirSeal® Electronic 120V 20W-50W MR16 (12V)
Note: Magnetic not recommended for residential or noise sensitive areas.
Features
1. Trim Kit Aperture Cone: Low brightness; 0.040" aluminum, anodized;
50° visual cut-off to lamp and lamp image. Hinged, and snaps on for easy
tool-less installation. Self-flange in painted white or aperture matching
polished flange. Flangeless trim used with Plaster Trim Ring accessory.
Interchangeable with other 3" Evolution trims.
2. Lamp Support: Die-form aluminum with knurled surface for easy gripping
during relamping. Spring tension clips hold lamp and lens and allow fast
snap-in, snap-out relamping. Matte black finish. Accepts up to two 2" diameter accessories.
3. Cover Glass: High temperature, soft focus lens.
4. Thick Ceiling Ready Brackets: Die-form steel, matte black finish. Adjust
trim kit vertically to accommodate up to 2" thick ceiling, lockable.
5. Lampholder: Procelain bi-pin socket. Pre-wired with No.18 AWG Teflon
leads.
6. Horizontal Adjustment Mechanism: Built-in ready for adjustable trim,
matte black finish.
7. Frame Vertical Adjustment Mechanism (C3LV): Accommodates mount-
ing to virtually any ceiling system using pre-installed mounting bars, or 1/2"
EMT tubing (by others). Single locking features secures all adjustments.
Alignment holes and markings allow fixture to be pre-set prior to installation.
Final adjustment can be made from below inside fixture.
8. Mounting Bars (C3LV): Galvanized steel, 0.048"; pre-installed telescoping
bars extend from 20" to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplified installation in 24"O.C. grid systems. Attaches to steel
or wood joists without accessories.
9. Transformer: Replaceable from below. Magnetic: 120V/277V 60 Hz. dualvoltage, core & coil. Note: Magnetic not recommended for residential or
noise sensitive areas. Electronic: 120V or 277V 50/60 Hz., regulated lamp
voltage, HPF, EMI and circuit protections, thermal auto-reset, quiet operation.
10. Frame-In Kit: See Frame-In Kit specification sheets for more information.
Non-IC and Non-IC AirSeal - Insulation must be kept 3"away from any parts
of the luminaire and must not be placed above luminaire in a manner which
will entrap heat. IC AirSeal - Luminaire may be in direct contact with thermal
insulation.
Options and Accessories
2" dia. Color Filters/Specialty filters: See ADF2/AF2 specification sheets
2" Dia. Louver: AL2HC
Plaster Trim Ring (use with flangeless trim): CA3FMR
Chicago Plenum: Consult Factory
Labels
U.L. (Suitable For Damp Locations), I.B.E.W.; U.S. & Foreign Patents Pending
*Lamp wattage restriction for Non-IC: 65W for up to 1" thick ceiling, 50W for
ceiling thickness greater than 1" (up to 2").
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • E1107
Calculite
®
Evolution Open Reflector Downlight C3MRD
Page 2 of 2 3" Aperture, MR16 (12V)
37W MR16 IR - 40° FLOOD SYLVANIA HALOGEN LAMP, LUMEN RATING = 840 LMS, 120V ELECTRONIC TRANSFORMER
CANDLEPOWER DISTRIBUTION
550˚
1100˚
1650˚
2200˚
** EFFICIENCY = 68.7% ** CERTIFIED TEST REPORT NO. 2741FR DATE: SEPT 24, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
SC = .4
ANGLE MEAN CP
LUMENS
0 2084
5 1685 159
10 1228
60˚
15 839 245
20 543
25 280 140
30 107
35 40 31
40 10
45 0 2
50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
30˚
85 0 0
90 0
LUMINANCE SUMMARY CD. / SQ.
ANGLE MEAN CD/SQ M
45 0
55 0
65 0
75 0
85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 543 64.75 94.30
0-40 574 68.44 99.67
0-60 576 68.67 100.00
0-90 576 68.67 100.00
40-90 1 0.23 0.33
60-90 0 0.00 0.00
90-180 0 0.00 0.00
0-180 576 68.67 100.00
M.
Coefficients of Utilization
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
LUMINAIRE INPUT WATTS = 38
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
0 .82 .82 .82 .82 .80 .80 .76 .76 .73 .73 .69
1 .80 .78 .77 .76 .77 .75 .74 .73 .72 .71 .67
2 .77 .75 .74 .72 .74 .71 .72 .70 .70 .68 .66
3 .75 .73 .71 .69 .72 .69 .70 .68 .69 .66 .65
4 .74 .71 .68 .67 .70 .66 .69 .65 .67 .65 .63
5 .72 .68 .66 .64 .68 .64 .67 .63 .66 .63 .62
6 .70 .67 .64 .63 .66 .62 .65 .62 .64 .61 .61
7 .68 .65 .62 .61 .64 .60 .64 .60 .63 .60 .59
8 .67 .63 .61 .59 .62 .59 .62 .59 .61 .58 .58
9 .65 .61 .59 .57 .61 .57 .61 .57 .60 .57 .56
10 .64 .60 .58 .56 .60 .56 .59 .56 .59 .56 .55
50W MR16 IR - 40° FLOOD GE HALOGEN LAMP, LUMEN RATING = 800 LMS, 120V ELECTRONIC TRANSFORMER
CANDLEPOWER DISTRIBUTION
500˚
1000˚
1500˚
2000˚
** EFFICIENCY = 68.7% ** CERTIFIED TEST REPORT NO. 2817FR DATE: NOV 12, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
SC = .4
ANGLE MEAN CP
LUMENS
0 1985
5 1605 152
10 1170
60˚
15 799 233
20 518
25 266 133
30 102
35 38 30
40 9
45 0 2
50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
30˚
80 0
85 0 0
90 0
LUMINANCE SUMMARY CD. / SQ.
ANGLE MEAN CD/SQ M
45 0
55 0
65 0
75 0
85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 518 64.75 94.30
0-40 547 68.44 99.67
0-60 549 68.67 100.00
0-90 549 68.67 100.00
40-90 1 0.23 0.33
60-90 0 0.00 0.00
90-180 0 0.00 0.00
0-180 549 68.67 100.00
M.
Coefficients of Utilization
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
LUMINAIRE INPUT WATTS = 51
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
0 .82 .82 .82 .82 .80 .80 .76 .76 .73 .73 .69
1 .80 .78 .77 .76 .77 .75 .74 .73 .72 .71 .67
2 .77 .75 .74 .72 .74 .71 .72 .70 .70 .68 .66
3 .75 .73 .71 .69 .72 .69 .70 .68 .69 .66 .65
4 .74 .71 .68 .67 .70 .66 .69 .65 .67 .65 .63
5 .72 .68 .66 .64 .68 .64 .67 .63 .66 .63 .62
6 .70 .67 .64 .63 .66 .62 .65 .62 .64 .61 .61
7 .68 .65 .62 .61 .64 .60 .64 .60 .63 .60 .59
8 .67 .63 .61 .59 .62 .59 .62 .59 .61 .58 .58
9 .65 .61 .59 .57 .61 .57 .61 .57 .60 .57 .56
10 .64 .60 .58 .56 .60 .56 .59 .56 .59 .56 .55
CL
Reflector
Finish
CL
Reflector
Finish
50W MR16 IR - 40° FLOOD SYLVANIA HALOGEN LAMP, LUMEN RATING = 1125 LMS, 120V ELECTRONIC TRANSFORMER
CANDLEPOWER DISTRIBUTION
750˚
1500˚
2250˚
3000˚
** EFFICIENCY = 68.8% ** CERTIFIED TEST REPORT NO. 2629FR DATE: MAY 12, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
SC = .4
ANGLE MEAN CP
LUMENS
0 2792
5 2258 214
10 1646
60˚
15 1125 328
20 729
25 375 188
30 144
35 55 42
40 14
45 0 3
50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
30˚
85 0 0
90 0
LUMINANCE SUMMARY CD. / SQ.
ANGLE MEAN CD/SQ M
45 0
55 0
65 0
75 0
85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 729 64.82 94.21
0-40 771 68.56 99.65
0-60 774 68.80 100.00
0-90 774 68.80 100.00
40-90 2 0.24 0.35
60-90 0 0.00 0.00
90-180 0 0.00 0.00
0-180 774 68.80 100.00
M.
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • E1107
Coefficients of Utilization
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
LUMINAIRE INPUT WATTS = 51
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
0 .82 .82 .82 .82 .80 .80 .76 .76 .73 .73 .69
1 .80 .78 .77 .76 .77 .75 .74 .73 .72 .71 .67
2 .77 .75 .74 .72 .74 .71 .72 .70 .70 .68 .66
3 .75 .73 .71 .69 .72 .69 .70 .68 .69 .66 .65
4 .74 .71 .68 .67 .70 .66 .69 .65 .67 .65 .63
5 .72 .68 .66 .64 .68 .64 .67 .63 .66 .63 .62
6 .70 .67 .64 .63 .66 .62 .65 .62 .64 .61 .61
7 .68 .65 .62 .61 .64 .60 .64 .60 .63 .60 .59
8 .67 .63 .61 .59 .62 .59 .62 .59 .61 .58 .58
9 .65 .61 .59 .57 .61 .57 .61 .57 .60 .57 .56
10 .64 .60 .58 .56 .60 .56 .59 .56 .59 .56 .55