C2 Series Emergency Lighting C2
Page 1 of 2 6 or 12 Volt 14 to 50 Watts Thermoplastic Housing
The C2 Series provides low profile, recessed emergency lighting for commercial interiors. It is also available as a master unit for remote operation.
24.0”
(61.0 cm)
12.0”
(30.5 cm)
Recessed depth is 4.3”
17”
(43.2 cm)
How to Specify:
C2
SERIES DC VOLTAGE BATTERY # OF LAMP HEADS HEADS
C2 = Recessed Emergency Lighting Unit
1 = 6 volt 2 = 12 volt
6V, Lead C alcium 25L = 25W Unit 50L = 50W Unit 6V, Nickel Cadmium 14N = 14W Unit 25N = 25W Unit 12V, Lead Calcium 50L = 50W Unit 12V, Nickel Cadmium 25N = 25W Unit 50N = 50W Unit
4 = Four 3 = Three 2 = Two
1 = One
Blank = No Lamp Heads
6V Round Wedge Base RT6 = 5.4W Tungsten RT7 = 7.2W Tungsten RT9 = 9W Tungsten RH7 = 7W Halogen RH10 = 10W Halogen RH12 = 12W Halogen 12V Round Wedge Base RT9 = 9W Tungsten RT12 = 12.5W Tungsten RT18 = 17.9W Tungsten RH12 = 12W Halogen
5.8”
(14.7 cm)
6.0”
(15.2 cm)
For additional lamp heads, see RT66 Specification Sheet
Features
1. Illumination: Allows up to four mounted lamp heads. The standard head
incorporates a high performance parabolic reflector with a wedge base
tungsten lamp. Allows maximum spacing between units along a path of
egress.
2. Housing: Constructed of 18 gauge steel with a white epoxy powder coat finish. Designed for easy drop-in installation into suspended ceilings.
3. Electronics: 120/277 VAC dual voltage input with surge-protected, solid­state circuitry. Charging system is complete with low voltage disconnect, AC lockout, brownout protection, AC indicator lamp and test switch.
4. Battery: Maintenance free, sealed lead calcium battery has an estimated service life of 5 years, and an operating temperature range of 65°F (19°C) to 85°F (30°C). Maintenance free, sealed nickel cadmium battery has an estimated service life of 10 years, and an operating temperature range of 20°F (-7°C) to 95°F (35°C).
5. Input Power Requirements: 120 VAC - 0.18 amps, 20 watts; 277 VAC - 0.08 amps, 20 watts
Code Compliance
UL 924 listed.
Options
SD = Self-Diagnostics SA = Self-Diagnostics with Alarm T1 = 120 VAC Time Delay T2 = 277 VAC Time Delay V = Voltmeter A = Ammeter F1 = 120 VAC Fuse F2 = 277 VAC Fuse P1 = 120 VAC Power Switch P2 = 277 VAC Power Switch
Multip le option c onfigurat ions may voi d UL listing. C onsult fac tory for specifics .
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • D0308
C2 Series Emergency Lighting C2
Page 2 of 2 6 or 12 Volt 14 to 50 Watts Thermoplastic Housing
Lamp Head Photometrics
RT6- 6 Volt, 5.4 Watt, Tungsten
RT9- 12 Volt, 9 Watt, Tungsten
RT7- 6 Volt, 7.2 Watt, Tungsten
RT12- 12 Volt, 12.5 Watt, Tungsten
RT9- 6 Volt, 9 Watt, Tungsten
RT18- 12 Volt, 18 Watt, Tungsten
Unit Battery Capacity
DC Suggested Watts to 871⁄2 Voltage Unit Lamp Head of Rated Voltage* 11⁄2 hrs. 2 hrs. 4 hrs. 8 hrs. 6 C2125L RT6 25 19 9.5 — C2150L RT9 50 37.5 19 10 C2114N RT6 14 10.5 — — C2125N RT6 25 19 9.5 — 12 C2250L RT9 50 37.5 19 10 C2225N RT9 25 19 9.5 — C2250N RT9 50 37.5 19 10
Lightolier is a Philips group brand
Warranty
Electronics: 3 years
Battery: 1 year full, 4 years pro-rata (lead calcium); 5 year full, 5 years pro-rata (nickel cadmium)
* Per NEC Specifications