Lightolier BSL14 User Manual

Lighting Systems Baselyte-BSL14


Page 1 of 7 1 Light T5 HO Semi-Indirect
Weight = 3.0 lb./ft
Ordering Information
Family
BSL
Distribution
5
5 = Semi-Indirect
Lamp Type
H
H = T5 HO
No. of Lamps
01
01 = 1 Light
Housing
LN
LN = Perforated 04 = 4’
Module Length
08 = 8’ 12 = 12’
Wiring
1 = 1cct.
3 = 1cct.
w/EC/NL
5 = 1cct.
w/EM Battery
7 = 1cct.
w/Dimming
8 = 1cct. w/1cct.
Thru wire
Note: Please consult wiring section of spec sheets for more wiring options.
Voltage
D = Dual 120V
& 277V
1 = 120V 2 = 277V
Note: Option‘D’ is standard. Voltage options 1 and 2 are only available with EM Battery and Dimming wiring options.
Ballast Finish
E = Standard
<10% THD
F = Standard
<10% THD w/fusing
C = Custom Color W = Standard
White
Specifications
Features
1. Housing: die-formed 20ga. cold rolled steel
2. End Set: die-cast metal with baked powder coat finish
3. Lamping: one T5 HO lamp
4. Configuration: 4’, 8’ and 12’ module lengths or continuous rows
5. Ballasts: electronic 120V or 277V
Finish
High-quality white powder coat with textured matte finish. Custom colors available. Consult factory.
Mounting
Aircraft cable gripper is tamper-resistant and provides infinite vertical adjustment capability. Aircraft cable, crimp and cable gripper independently tested to meet stringent safety requirements.
Electrical
All luminaires are factory pre-wired to module ends with quick-wire connectors.
Joints & Intersections
Self-aligning joining system with hands-free pre-joining wire access.
Labels
UL, CSA standards.
Ordering Instructions
Individual Fixtures
1. Determine the number of individual modules required
2. Order one end set per module
3. Order one non-power mount per module
4. Order one power mount per module
Continuous Rows*
1. Determine run length
2. Order the appropriate number and length of modules for complete run
3. Order one end set for each run
4. Order one non-power mount for each module
5. Order one power mount per run
6. Order one joiner per module minus one (e.g. 3 modules requires 2 joiners)
*Note: Some runs may require additional power mounts. Please see the ‘Run Configuration’ table on the next page for more details.
Job Information
Job Name:
Cat. No.:
Lamp(s):
Notes:
Type:
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 Genlyte Group LLC • 0205 Rev.1
Lighting Systems Baselyte-BSL14
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Candlepower Summar
y
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 1073 1073 1073 1073 1073 175 1067 1069 1072 1074 1075 165 1027 1036 1054 1069 1074 155 954 974 1016 1053 1066 145 848 885 960 1028 1051 135 713 774 894 1005 1042 125 553 648 844 1042 1084 115 380 533 826 881 922 105 198 457 583 628 661
95 43 126 67 27 28 90 2 3 5 6 7 85 4 4 5 6 6 75 5 6 6 7 7 65 5 7 9 10 10 55 6 8 10 12 12 45 8 9 11 12 13 35 10 10 13 13 13 25 11 12 13 14 14 15 12 12 13 14 14
5 12 12 12 13 12 0 12 12 12 12 12
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10 0 88 88 88 75 75 75 52 52 52 1 76 73 70 65 63 60 45 43 42 2 66 61 57 57 53 49 39 37 34 3 58 52 47 50 45 41 34 31 29 4 51 44 39 44 38 34 30 27 24 5 45 38 33 39 33 29 27 23 20 6 40 33 28 34 29 25 24 20 17 7 36 29 24 31 25 21 21 18 15 8 32 26 21 28 22 18 19 16 13 9 29 23 18 25 20 16 17 14 11
10 26 20 16 23 18 14 16 12 10
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90 90-180 0-180
4321
4267.5
53.5 1.2
98.8
100.0
1.2
91.8
92.9






















Page 2 of 7 1 Light T5 HO Semi-Indirect
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Report No: 9900245 Lamps: F54T54 Lumens per Lamp: 4650 Efficiency: 92.9% Up: 98.8% Down: 1.2%
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE
Module Lengths & Mounting Distances
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
System Components & Accessories
End Set
BSLESW = suspended standard white
Joiner
BSLJS = suspended joiner
Job Information Type:
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 Genlyte Group LLC • 0205 Rev.1
Run Configuration
Run
Length
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
16’ run
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.
4’
Module8’Module
12’
Joiner End Set Mount
Module
1 1 1 1
2 1 1 2 1
Power
Mount*
Lighting Systems Baselyte-BSL14
Page 3 of 7 1 Light T5 HO Semi-Indirect
Mounting Options
Mount Type: T-Bar 15/16” (On-Grid)*
Non-Power Mount1-Power Mount
Supension Length
2’ 4’ 8’ 12’
BSLM6102P13 BSLM6104P13 BSLM6108P13 BSLM6112P13
BSLM6102P14 BSLM6104P14 BSLM6108P14 BSLM6112P14
BSLM6102P17 BSLM6104P17 BSLM6108P17 BSLM6112P17
BSLM6102N BSLM6104N BSLM6108N BSLM6112N
• 65 lbs maximum load
• Canopy: Diameter of 3 3/4“x 7/32”
• Cable: 7x7 stranded aircraft cable
• Supported by T-bar and secured to structure
• J-Box: 4” square (supplied by others)
• Fully adjustable vertically at fixture
Mount Type: T-Bar 9/16” (On-Grid)*
1-Power Mount
3 Conductor
4 Conductor
7 Conductor
Non-Power Mount
• 65 lbs maximum load
• Canopy: Diameter of 3 3/4“x 7/32”
• Cable: 7x7 stranded aircraft cable
• Supported by T-bar and secured to structure
• J-Box: 4” square (supplied by others)
• Fully adjustable vertically at fixture
Mount Type: T-Bar 9/16” by 5/16” Slot Grid (On-Grid)*
• 65 lbs maximum load
• Canopy: Diameter of 3 3/4“x 7/32”
• Cable: 7x7 stranded aircraft cable
• Supported by T-bar and secured to structure
• J-Box: 4” square (supplied by others)
• Fully adjustable vertically at fixture
*Note: Standard T-bar mounts are currently not available for tegular tile ceilings,
however slot-grid mount. For more information, please consult factory.
certain tegular tile / T-bar combinations may be supported by the use of the
Non-Power Mount1-Power Mount
Supension Length
1-Power Mount
3 Conductor
4 Conductor
7 Conductor
Non-Power Mount
2’ 4’ 8’ 12’
BSLM6202P13 BSLM6204P13 BSLM6208P13 BSLM6212P13
BSLM6202P14 BSLM6204P14 BSLM6208P14 BSLM6212P14
BSLM6202P17 BSLM6204P17 BSLM6208P17 BSLM6212P17
BSLM6202N BSLM6204N BSLM6208N BSLM6212N
Non-Power Mount1-Power Mount
Supension Length
1-Power Mount
3 Conductor
4 Conductor
7 Conductor
Non-Power Mount
2’ 4’ 8’ 12’
BSLM6302P13 BSLM6304P13 BSLM6308P13 BSLM6312P13
BSLM6302P14 BSLM6304P14 BSLM6308P14 BSLM6312P14
BSLM6302P17 BSLM6304P17 BSLM6308P17 BSLM6312P17
BSLM6302N BSLM6304N BSLM6308N BSLM6312N
Job Information Type:
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 Genlyte Group LLC • 0205 Rev.1
Loading...