Lightolier 1101HIE User Manual

Lytecaster
7 7/8"
6 1/2"
6 3/8"
®
Performance Recessed CFL Downlighting 1101HIE
Page 1 of 2 6 ¾" Aperture Horizontal Open Downlight, Compact Fluorescent, Performance Series, Integrated Emergency, Reflector Trim
Complete Fixture consist s of Frame-In Kit and Reflector Trim. Select each separately.
Uniframe™ Compact Fluorescent Performance Series Reflector Trims
Catalog No. Description Catalog No. Installation Type Lamping
1101HCL IE
1101HCDIE
Features
1. Reflector: Formed aluminum. Matte White flange.
2. Finishes: CL = Specular Clear (Iridescent Free coating) CD = Clear Diffuse
3. Performance Data: 60° Cutoff angle.
See at tached photometric repor ts for distribution and efficiency data. Go to w ww.lightolier.com for .IES files.
6 ¾" Horizontal Open Downlight - Integrated Emergency - Specular Clear
6 ¾" Horizontal Open Downlight - Integrated Emergency - Clear Diffuse 32W Triple
Labels
cULus Listed. Suitable for Damp Locations. I.B.E.W.
Compatible Frame In Kits
(See Individual Frame-In Kit Specification Sheets)
1101F2642UEL
Uniframe™ Non-IC High-Lumen Emergency 120/277V
26W Quad/Triple
42W Triple
Job Information Type:
Job Name:
Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC • A1207
Lytecaster
®
Performance Recessed CFL Downlighting 1101HIE
Page 2 of 2 6 ¾" Aperture Horizontal Open Downlight, Compact Fluorescent, Performance Series, Integrated Emergency, Reflector Trim
32W TRIPLE TUBE LAMP, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
0
181
363
544
725
SC = 1.1 1 = 9 0˚ 2 = 0˚
CERTI FIED TEST RE PORT NO. 3166 FR COMPU TED BY LSI PR OGRAM **TEST- LITE**
2
1
30˚
CANDLEPOWER SUMMARY
Angle 0˚ CP 90˚ CP
0 720 720
5 722 725 10 68 9 697 15 641 633
60˚
20 62 6 558 25 62 1 535 30 5 73 569 35 49 2 483 40 416 3 99 45 38 3 336 50 36 6 321 55 318 30 6 60 42 44 65 9 9 70 5 6 75 4 4 80 3 3 85 2 3 90 2 3
ZONA L LUMEN SUMM ARY
Z one Lumens
90-10 0 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180
0-10 10-20 20-3 0 30- 40 40- 50 50- 60 60-70 70-8 0 80- 90
68.47
181.71
266. 5
310.46
281.1
229.0 4
13.53
4.17
2.98 0 0 0 0 0 0 0 0 0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-3 0 516. 68 23.5 38 0-4 0 827.14 37.6 60.9 0-6 0 1337.28 60 .8 9 8.5 0-9 0 1357.97 61.7 100
90-120 0 0 0 90-150 0 0 0 90-180 0 0 0
0-180 1357.97 61.7 100
Efficiency = 61.7% **
**
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
COEFFICIENTS OF UTILIZATION
0 73 73 73 73 72 72 69 69 66 66 62 1 69 67 65 63 65 62 63 60 61 58 55 2 64 60 57 54 59 54 57 52 55 51 49 3 59 54 50 47 53 47 52 46 50 45 43 4 55 49 44 41 48 41 47 40 45 40 38 5 51 44 40 36 44 36 42 36 41 35 34 6 48 40 36 32 40 32 39 32 38 34 31 7 44 37 32 29 36 29 35 28 35 31 28 8 41 34 29 26 33 26 33 26 32 28 26 9 39 31 27 23 31 23 30 23 30 26 23
10 36 29 24 21 29 21 28 21 27 24 21
Luminai re Input Wa tts = 33. 0
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC • A1207