Lytecaster
6 3/8"
7 7/8"
6 1/2"
5 1/2"
®
Performance Recessed CFL Downlighting 1101HCB
Page 1 of 2 6 ¾" Aperture Horizontal Cross Blade, Compact Fluorescent, Performance Series,
Reflector Trim
Complete Fixture consist s of Frame-In Kit and Reflector Trim. Select each separately.
Uniframe™ Compact Fluorescent
Performance Series Reflector Trims
Catalog No. Description Catalog No. Installation Type Lamping
1101HACB
1101HWHCB
6-3/4” Horizontal Shielded Cross Blade –
Aluminum
6-3/4” Horizontal Shielded Cross Blade –
Matte White
Features
1. Reflector: Formed aluminum. Matte White flange.
2. Finishes: WH = Matte White Paint
A = Aluminum Paint
3. Cross Blade: .050" thick aluminum "floating" cross blade painted white or
aluminum.
4. Performance Data: 60° Cutoff angle.
See at tached photometric repor ts for distribution and efficiency data.
Go to w ww.lightolier.com for .IES files.
Compatible Frame-In Kits
(See Individual Frame-In Kit Specification Sheets)
1101F18U
1101FR18U
1101FD26L1
1101FD26L2
1101FD32L1
1101FD32L2
1101F2642U
1101FR 2642U
1101F2642UEM
1101FD2642MX1
1101FD2642MX 2
1101FD2642M7U
1101F18ICU/N
1101F2642ICU
1101F2642IUN
1101FDICMX1/N
1101FDICMX2 /N
Uniframe™ Non-IC 120/277v
Uniframe™ Non-IC Remodeler 120/277v
Uniframe™ Non-IC Lutron Dimming 120v
Uniframe™ Non-IC Lutron Dimming 277v
Uniframe™ Non-IC Lutron Dimming 120v
Uniframe™ Non-IC Lutron Dimming 277v
Uniframe™ Non-IC 120/277v
Uniframe™ Non-IC Remodeler 120/277v
Uniframe™ Non-IC Emergency 120/277v
Uniframe™ Non-IC Advance Mark10 Dimming 120v
Uniframe™ Non-IC Advance Mark10 Dimming 277v
Uniframe™ Non-IC Advance Mark7 Dimming 120/277v
Performance IC 120/277v 18w Quad/ Triple
Performance IC 120/277v 26w Quad/Triple
Performance IC Advance Mark10 Dimming 120v 26w Quad/Triple
Performance IC Advance Mark10 Dimming 277v 26w Quad/Triple
Labels
cULus Listed. Suitable for Damp Locations. I.B.E.W.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
18w Quad/ Triple
26w Quad/Triple
32w Triple
26w Quad/Triple
32w Triple
42w Triple
32w Triple
42w Triple
32w Triple
32w Triple
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • C1007
Lytecaster
®
Performance Recessed CFL Downlighting 1101HCB
Page 2 of 2 6 ¾" Aperture Horizontal Cross Blade, Compact Fluorescent, Performance Series,
32W TRIPLE TUBE LAMP, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, WHITE CROSS BLADE
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
0
44 44 4 4 44 43 43 41 41 39 39 3 7
1
41 4 0 38 37 39 3 7 37 36 36 34 33
2
38 36 3 4 32 35 32 34 31 33 30 2 9
3
36 32 3 0 28 35 32 28 31 27 30 26
4
33 30 2 7 25 29 25 28 24 27 26 2 3
5
31 2 7 24 22 27 2 2 26 22 25 22 21
6
29 25 2 2 20 25 20 24 2 0 23 20 19
7
27 23 2 0 18 23 18 22 18 22 18 17
Room Cavity Ratio
8
26 21 19 17 21 17 21 17 20 17 16
36
24 2 0 17 16 20 16 19 16 19 15 15
10
23 19 16 15 19 14 18 14 18 14 14
Determined In Accordance With Current IES Published Procedures
167
333
500
666
SC = 0.8 x 0.98
1 – 0°
2 – 90°
CERTI FIED TEST RE PORT NO. 33 53FR
COMPU TED BY LSI PR OGRAM
**TEST- LITE**
CANDLEPOWER SUMMARY
Angle 0˚ CP 90˚ CP
0 66 6 66 6
5 635 637
60˚
10 572 59 7
15 494 582
20 432 52 8
25 383 46 8
30 324 4 01
35 263 28 7
40 193 177
45 142 116
50 106 97
55 8 0 80
60 6 4 64
30˚
65 51 51
70 39 39
75 27 28
80 17 18
85 8 9
90 5 5
ZONA L LUMEN SUMM ARY
Zone Lum ens
10-20
20-3 0
30- 40
40- 50
50- 60
60-70
70-8 0
80- 90
90-10 0
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
0-10
59.9 5
147.91
183.79
159.87
103.2
72.98
50.18
28.8
9.7
0
0
0
0
0
0
0
0
0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 3 90.66 17.8 47.9
0-40 5 50.53 25 67.5
0-60 7 26.61 33 89.1
0-90 815 .38 37.1 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0
90-180 815 .38 37.1 100
Efficiency = 37.1% **
**
COEFFICIENTS OF UTILIZATION
Luminai re Input Wa tts = 35
Reflector Trim
42W TRIPLE TUBE LAMP, LUMEN RATING = 3200 LMS, ELECTRONIC BALLAST, WHITE CROSS BLADE
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
0 3 9 39 39 3 9 38 38 36 3 6 35 35 33
1 3 6 35 34 3 3 34 32 33 31 32 30 2 9
2 3 4 31 30 2 8 31 28 30 27 29 27 25
3 31 29 26 25 28 24 27 24 26 24 2 3
4 2 9 26 24 2 2 26 22 25 21 24 21 20
5 2 7 24 21 20 23 19 21 19 20 19 18
6 2 6 22 19 18 22 18 21 17 21 17 17
7 24 20 18 16 20 16 20 16 19 16 15
Room Cavity Ratio
8 2 3 19 16 15 19 15 18 15 18 15 14
36 21 18 15 14 17 14 17 14 17 14 13
10 2 0 16 14 13 16 13 16 13 16 13 12
Determined In Accordance With Current IES Published Procedures
225
450
695
900
SC = 0.8 x 1.0
1 – 0°
2 – 90°
CERTI FIED TEST RE PORT NO. 33 56FR
COMPU TED BY LSI PR OGRAM
**TEST- LITE**
CANDLEPOWER SUMMARY
60°
Angle 0˚ CP 90˚ CP
0
816 816
5
778 801
10
701 774
15
604 751
20
526 6 88
25
466 599
30
394 503
35
325 36 9
40
249 232
45
50
55
60
65
70
75
80
85
90
185 154
136 124
104 102
82 82
65 65
50 49
35 35
22 22
11 11
2 4
30°
ZONA L LUMEN SUMM ARY
Zone Lum ens
0-10 73.6 4
10-20 18 8.16
20-3 0 23 6.24
30- 40 2 03
40- 50 134.4 8
50- 60 94.28
60-70 64.6
70-8 0 36.97
80- 90 12.35
90-10 0 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 49 8.04 15.6 47.7
0-40 701.05 21.9 67.2
0-60 929.8 29.1 89 .1
0-90 1043.73 32 .6 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0 0
90-180 1043.73 32 .6 10 0
Efficiency = 32.6% **
**
COEFFICIENTS OF UTILIZATION
Luminai re Input Wa tts = 47
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • C1007