Instruction Sheet Number 1101FIC
Page 1 of 2 Installation Procedure for High Wattage Insulated Ceiling
Frame-In Kits 100IFIC, 1101FIC, 2001FIC
Read and understand these instructions before installing fixture.
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and
regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
New Construction
NOTE: I.C. Frame-In Kit may be used in direct contact with insulation.
Fig. A
Frame-In
Fig. B
Wire-In
Fig. C
Swing-Up
Fig. D
Close-In
Fig. E
Snap-On
Warning: Use Only With Lightolier Reflector Trims Marked With I.C. Lamping Information.
Use of Other Manufacturers’ Trims Voids the Underwriters Laboratories Listing and Could Constitute A Fire Hazard
1. FRAME-IN (Fig. A)
Locate fixture along joist and line up bottom edge of HINGED MOUNTING BAR
with the bottom of joist and fasten in place.
5 3/4" 2001FR
5 1/4" 1004ICX
5 5/8" 1101FIC
CENTER LINE OF
5 7/8" 2001FIC
6 3/8" 1001FIC
6" 1101FIC
APERTURE OPENING
Note: Integral nail version available
HINGED MOUNTING BAR
BEND AT HOLE
For suspended ceilings:
• Rotate HINGED BAR ENDS to position shown and fully extend bars.
• Crimp bottom of edge of CHANNEL to prevent rotation of
HINGED BAR ENDS.
• Bend NON-HINGED end of mounting bar at featured hole location and
extend out.
• Position notched area of MOUNTING BARS onto T-BAR and lock by
bending TAB underneath T-BAR BEAD as shown.
• For suspended ceiling, make cer tain that bottom of Mounting Frame is no
higher than 1" above ceiling line.
Fig. F
Push-Up
TAB
BEND AT TAB
For Joist Spacing Less Than 16" On Center (To 12 " On Center):
• MOUNTING BAR CHANNELS can be shor tened and used as nailing
legs in tight spaces. Simply remove INNER BAR from holed CHANNEL,
bend CHANNEL at appropriate point and use extra screw to secure it
to the joist. (Fig. G)
HINGED BAR ENDS
CHANNEL
T-BAR
TAB
Fig. G