Please follow the steps below referring to Figure 1 to ensure
proper operation of your LM202 Vehicle Probe with your
LiftMaster LA400 Gate Operator.
NOTE:
Do not install the probe close to any electrical wires. Do
not run the lead in cable in the same conduit as other electrical
wires.
INSTALLATION
1. Select a location parallel to the driveway to install the probe.
A. The probe may be buried up to 10" deep, provided there is
no rebar located below it.
B. The probe may also be placed above ground, provided it
remains undisturbed and free of vibrations.
2. Run the attached wire to the LA400 Control Box, making sure
it is kept out of the way of gardening equipment.
3. See the reverse side of this sheet for proper wiring
installation.
LM202 Vehicle Sensing Probe
Installation and Wiring
Instructions
Telephone
Entry System
STREET
25' Min.
8-10"
LM202
Vehicle Probe
Typical Read Range
(approx. 15' Radius)
©2005, The Chamberlain Group, Inc.
01-32706B All Rights Reserved
WIRING INSTRUCTIONS
1. Connect the BROWN (-) wire from the LM202 to the OPEN
terminal on the control board (Figure 2).
2. Connect the GREEN (N/O) wire from the LM202 to the COM
terminal on the control board (Figure 2).
NOTE:
The WHITE
wire is not used.
3. Connect the RED and BLACK power wires from the LM202 to
the J13 Accessory Power terminal on the control board
(Figure 3).
NOTE:
Polarity is not important.
4. Upon device power up, please allow at least 60 seconds for
the unit to properly initialize.
COM
COM
CONTROL
INPUTS
OPEN
SINGLE BUTTON
RESET
STOP
POWER
OPEN
COMMON
Connection to LA400 Control Board
GREEN
BROWN
To LM202
Vehicle Probe
ACCESSORY
POWER
24V
Z22
R91
CLOSE
EDGE
R94
R92
R93
L1
R1
R2
Z1
K5
Ø
14GPØ89ØE
Ø
14LGØ89ØE
Ø
14SKØ89ØE
K6
K2
F3
10A 32V
D1
Ø
OPEN EDGE/
PHOTO
OPEN
PHOTO
CLOSE
PHOTO
J18
R227
R2
Ø
7
Z2
Ø
R223
1
P
Z9
Z8
F2
F6
D4D2R9
C64
JMPR1
R224
U4
P2
1J
J19
SINGLE
BUTTON
CONTROL
INPUTS
FORCE
BIPART
DELAY
TIMER TO
CLOSE
MIN MAX OFF MAX OFF MAX
OPEN
SINGLE BUTTON
RESET
STOP
SHADOW
S1
INTERRUPT
CHGR
OVLD
COM
COM
COM
FUSE
OPEN
LOOP
INPUTS
POWER
BATT 1BATT 2
F1 2
0
A 32V
R35
D9
Z3
Z4
U3
D1
D27
F5
C11
C13
C12
D15
C2R4
R1
Ø
1
R1
ØØ
R9
Ø
Q9
K1
R196
Q22
D8
K3
K4
D21
D22
C4
ACCESSORY
OVLD
6D
JMPR2
MOV1
MOV2
DB1
U2
Z12
24 VAC/
SOLAR
INPUT
GATE 2
ACCESSORY
POWER
MAGLOCK
ALARM
GATE 1
C
C
NC
NO
NO
GRN
WHT
YEL
BLU
RED
BRN
GRN
WHT
YEL
BLU
RED
BRN
F4
10A 32V
F7
24V
24V
COM
OVLD
OVLD
SWITCHED
ACCESSORY
POWER
TIMER
RUNNING
GATE 2
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
LEARN
LIMITS
DIAGNOSTIC
GATE 1
J4
SAVE
MAGLOCK
MODE
EDGE
PHOTO
OFF
OFF
SINGLE
NO
NO
ON
ON
DUAL
NC
NC
LEARN
XMITTER
S8
5
4
3
2
1
O
N
2
1
RED
Figure 2
To prevent possible SERIOUS INJURY or DEATH from
electrocution, disconnect power to operator BEFORE
proceeding.
Figure 3
For Technical Support Call Our Toll Free Number:
1-888-528-2806