Limit Switch Assembly
APPLICATION REQUIREMENTS:
Replacement of Limit Switch and/or its components for a Model FDC Operator.
INSTALLATION INSTRUCTIONS
NOTE: Refer to the Owner’s Manual supplied with the
operator for all mounting and wiring instructions.
REMOVE EXISTING LIMIT SWITCH ASSEMBLY:
Disconnect the wire connections to the limit switches.
Remove the six screws from the nut plates. Remove the
limit switches, back-up plates and standoffs from the
electrical box and discard.
Remove the two 1” screws from the locknuts. Remove the
depress plate and depress plate springs and discard.
INSTALLING NEW LIMIT ASSEMBLY:
To install the new limit assembly, follow the steps outlined
above in the reverse order. Reconnect the wires to the
new limit switches, referring to the owners manual and
illustration below.
NOTE: Other components not
shown in box for easier viewing.
DISCONNECT POWER AT THE FUSE BOX BEFORE
PROCEEDING. IF NECESSARY REMOVE THE
OPERATOR FROM ITS MOUNTED POSITION.
OPERATOR MUST BE PROPERLY GROUNDED AND
CONNECTED IN ACCORDANCE WITH LOCAL
ELECTRICAL CODES. NOTE: THE OPERATOR
SHOULD BE ON A SEPARATE FUSED LINE OF
ADEQUATE CAPACITY.
ALL ELECTRICAL CONNECTIONS MUST BE MADE
BY A QUALIFIED INDIVIDUAL.
WIRE CONNECTIONS
OPEN
LIMIT
NC
NO
(WH)
C
(WH)
Replacement Kit for
FDC-Line Operators
WARNING
(BL)
(YE)
(WH)
(RD)
NC
NO
NC
NO
SAFETY
LIMIT
C
CLOSE
LIMIT
C
J3 CONNECTOR
01-16521A All Rights Reserved MADE IN MEXICO
© 2000, The Chamberlain Group, Inc.