LiftMaster LGJ User Manual

Page 1
OWNER'S MANUAL
MODELS:
LGJ & MGJ
INDUSTRIAL DUTY DOOR OPERATOR
NOT FOR RESIDENTIAL USE
LISTED DOOR OPERATOR
Serial #
(located on electrical box cover)
Installation Date
Wiring Type
2 YEAR WARRANTY
Page 2

SPECIFICATIONS

MOTOR
TYPE: .................................Intermittent Duty
HORSEPOWER: ................MGJ: 1/2Hp 1 or 3 Phase
LGJ: 1/4 Hp 1 Phase
SPEED:...............................MGJ: 1050 RPM
LGJ: 1725 RPM
VOLTAGE:..........................MGJ: 115, 60HZ, 1Ph
230V, 50 or 60Hz, 3Ph
230V, 60Hz, 1Ph
380V, 50Hz, 3Ph
460V, 60Hz, 3Ph
LGJ: 115V, 60Hz, 1Ph
CURRENT: See motor nameplate
MECHANICAL
DRIVE REDUCTION: ... . . . . . . . . . . . . 40:1 Reduction
(Heavy duty wormgear-in-oil-bath speed reducer)
OUTPUT SPROCKET:...........Size #41
DOOR SPEED: . . . . . . . . . . MGJ: 1Ph, 23RPM
3Ph, 39RPM
LGJ: .1Ph, 43RPM
BEARINGS: .................Heavy duty wormgear-in-oil-bath
speed reducer.
ELECTRICAL
T
RANSFORMER:.............24VAC
CONTROL STATION: ......NEMA 1 three button station.
WIRING TYPE: MGJ: B2-C2 (Factory Shipped)
See pages 13 and 14 for optional control settings and operating modes.
LIMIT ADJUST: ................Linear driven, fully adjustable
screw type cams. Adjustable to 24 feet.
OPEN/CLOSE/STOP
LGJ: G2 (Factory Shipped)
SAFETY
DISCONNECT :.......................Floor level disconnect for
emergency manual door operation.
REVERSING EDGE: ...............(Optional) Electric or
pneumatic sensing device attached to the bottom edge of door
A REVERSING EDGE IS STRONGLY RECOMMENDED FOR ALL COMMERCIAL OPERATOR INSTALLATIONS. REQUIRED WHEN THE 3 BUTTON CONTROL STATION IS OUT OF SIGHT OF DOOR OR ANY OTHER CONTROL (AUTOMATIC OR MANUAL) IS USED.
MGJ WEIGHTS AND DIMENSIONS
HANGING WEIGHT:..........80-110 LBS.
7.50”
11.05”
7.00”
9.25”
LGJ WEIGHTS AND DIMENSIONS
HANGING WEIGHT:..........80-110 LBS.
7.90”
10.50”
11.00”
3.00”
MOUNTING DIMENSIONS
5.50”
4.75”
.98”
1.96”
4.50”
2.25”
8.90”
1.97”
MOUNTING DIMENSIONS
10.88”
2
Page 3
3
TO AVOID DAMAGE TO DOOR AND OPERATOR, MAKE ALL DOOR LOCKS INOPERATIVE. SECURE LOCK(S) IN "OPEN" POSITION.
IF THE DOOR LOCK NEEDS TO REMAIN FUNCTIONAL, INSTALL AN INTERLOCK SWITCH.
DO NOT CONNECT ELECTRIC POWER UNTIL INSTRUCTED TO DO SO.
KEEP DOOR BALANCED. STICKING OR BINDING DOORS MUST BE REPAIRED. DOORS, DOOR SPRINGS, CABLES, PULLEYS, BRACKETS AND THEIR HARDWARE MAY BE UNDER EXTREME TENSION AND CAN CAUSE SERIOUS PERSONAL INJURY. CALL A PROFESSIONAL DOOR SERVICEMAN TO MOVE OR ADJUST DOOR SPRINGS OR HARDWARE.
WARNING
CAUTION
WARNING
WARNING
WARNING
SITE PREPARATIONS
It is imperative that the wall or mounting surface provide adequate support for the operator. This surface must:
a) Be rigid to prevent play between operator and door shaft. b) Provide a level base. c) Permit the operator to be fastened securely and with the drive shaft parallel to the door shaft.
The safety and wear of the operator will be adversely affected if any of the above requirements are not met.
For metal buildings, fasten 2” x 2” x 3/16” (or larger) angle iron frames to the building purlins. For proper spacing, retain .2.75” between for model MGJ, butt purlins together for model LGJ. See Figure 1.
OPERATOR PREPARATION
IMPORTANT SAFETY NOTES
2.75 for MGJ, butt together for LGJ
Model LGJ: Shipped from the factory for right hand mounting, refer to preparation instructions on page 4 for
Left hand mounting.
Model MGJ: Shipped from the factory for either left hand or right hand mounting. Refer to the last digit in the
model number for handing of your unit. If necessary, model MGJ may also be field modified to accommodate opposite handing. Refer to the conversion instructions below and on page 4.
KEYS
SPRING
DISC
HUB
E RING
SPROCKET
YOKE
BRACKET
SHAFT
DISC
LEVER
MGJ OPPOSITE HANDING PREPARATIONS
1. Remove Disconnect Assembly Components
Remove the master link from the limit chain, remove the chain and set it aside.
Remove the two E Rings securing the sprocket on the gear reducer shaft. Remove the screws securing the yoke to the disconnect shaft, set the yoke aside.
CAUTION
WARNING
Shaft Support Bracket with Bearing (Not Supplied)
Door Sprocket
2-1/4"
FIGURE 1
Page 4
Remove the three cotter pins from the disconnect shaft. Do not discard the pins. Slide the disconnect shaft out of the support bracket. The release lever will now be free inside the motor frame. Remove the release lever and sash chain from the motor frame. Slide the disconnect hub, compression spring, and flatwasher
2. Re-assemble Disconnect Assembly
Remove the two screws on the opposite side of the gear reducer and mount the disconnect support bracket with the notched side facing the motor. For the remainder of the installation, follow the steps outlined above in
reverse order, referring to the illustration as necessary. from the end of the gear reducer shaft. Remove the disconnect support bracket by first removing the the two gear reducer housing screws. Replace the screws in the gear reducer and firmly tighten.
LGJ LEFT HAND MOUNTING PREPARATIONS
LGJ Operators are assembled at the factory to be installed in a right hand (motor side up) configuration. To install an LGJ Operator on the left hand side of your door (motor side down), complete the three steps described below.
1. Reconfigure Disconnect Chain Assembly
The default configuration for the disconnect chain assembly is shown in Figure 1. This configuration allows the chain to hang freely when the operator is mounted on right side only. To insure smooth operation of the disconnect chain assembly when mounted motor side down, reconfigure as
described below and as shown in figures 2 and 3.
1. Disconnect the key ring from the release cable.
2. Thread the release cable through the slot on the outermost edge of the support bracket, as shown in Figure
2.
3. Re-attach the key ring and sash chain to the end of the loop of release cable.
FIGURE 1
HOUR GLASS CABLE SLEEVE
2. Set Limit Switch Direction
Locate Switch #1 on PCB in the electrical box. Place pole #2 of Switch #1 in the “OFF” position. With this setting limit switch labeled “A” is the close switch, limit switch labeled “B” is the open switch.
IMPORTANT: Refer to page 9 for for complete instructions on setting of limit switches.
3. Affix Electrical Box Cover Caution Label
Place the caution label on electrical box cover such that the text is read in the opposite direction of silkscreen.
SLOT
RELEASE CABLE
SUPPORT BRACKET
KEY RING
SASH CHAIN
Disconnect Cable as shipped from the factory
4
Page 5
5
FIGURE 3
LABEL
SILK
SCREEN
HOUR GLASS CABLE SLEEVE
RELEASE CABLE
SUPPORT BRACKET
SLOT
SASH CHAIN
KEY RING
FIGURE 2
Disconnect Cable Re-routed for Left Hand Mounting
Page 6

OPERATOR MOUNTING

Before your operator is installed, be sure the door has been properly aligned and is working smoothly. The operator may be wall mounted or mounted on a bracket or shelf. If necessary, refer to the operator preparations on page 3. Refer to the illustration and instructions below that suits your application.
1a. Wall Mounting
The operator should generally be installed below the door shaft, and as close to the door as possible. The optimum distance between the door shaft and operator drive shaft is between 12” - 15”. Refer to Figure 3.
1b. Bracket or Shelf Mounting
The operator may be mounted either above or below the door shaft. The optimum distance between the door shaft and operator drive shaft is between 12” - 15”. Refer to Figure 4.
OPTIONAL (LGJ) Mounting Bracket
OPTIONAL (MGJ) Mounting Bracket P/N 10-9098
Typical Right Hand Wall Mounted Operator
1c. Place door sprocket on the door shaft. Do not
insert the key at this time.
2. Wrap drive chain around door sprocket and join roller chain ends together with master link.
3. Raise operator to approximate mounting position and position chain over operator sprocket.
4. Raise or lower operator until the chain is slightly taut (not tight). Make sure the operator output shaft is parallel to door shaft and sprockets are aligned. When in position, secure the operator to wall or mounting bracket.
5. Align sprockets and secure, (see Figure 5).
IMPORTANT: The shelf or bracket must provide adequate support, prevent play between operator and door shaft, and permit operator to be fastened securely and with the drive shaft parallel to the door shaft.
FIGURE 4FIGURE 3
Be sure door sprocket is properly aligned with drive before securing to the shaft.
Chain Keeper
6
FIGURE 5
Page 7
7

EMERGENCY MANUAL OPERATION

This operator a floor level disconnect chain to disconnect the door from the door operator allowing for manual operation of the door in case of emergency or power failure.
1. To disengage, pull the chain and secure in the disengaged position by slipping the end through the keyhole bracket mounted on the wall. Or if emergency egress device is used, pull handle to disengage operator from door.
2. The door may now be pushed up or pulled down manually. Release the disconnect chain to operate the door again electrically.
Keyhole Bracket
6. Mount Chain Keeper / Keyhole Bracket Using suitable hardware mount the chain keeper approximately 4 feet above the floor, near the free hanging chain. Remove disconnect sash chain from bag and place the end through the keyhole in the the chain keeper. Remove excess links if necessary.
TURN OFF POWER TO THE OPERATOR BEFORE MANUALLY OPERATING YOUR DOOR.
WARNING
CAUTION
WARNING
WARNING
Pull sash chain and secure in bracket for manual operation of the door.
CAUTION
Page 8
WARNING
ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL)
SENSING EDGES
All types of sensing edges with an isolated normally open (N.O.) output are compatible with your operator. This includes pneumatic and electric edges. If your door does not have a bottom sensing edge and you wish to purchase one, contact the supplier of your operator.
If not pre-installed by the door manufacturer, mount the sensing edge on the door according to the instructions provided with the edge. The sensing edge may be electrically connected by either coiled cord or take-up reel. Refer to the steps below
Important Notes:
a) Proceed with Limit Switch Adjustments before
making any sensing edge wiring connections to operator as described below.
b) Electrician must hardwire the junction box to the
operator electrical box in accordance with local codes.
MGJ LIMIT SWITCH ADJUSTMENT
IT IS STRONGLY RECOMMENDED THAT A SENSING EDGE OR OTHER ENTRAPMENT PROTECTION DEVICE BE USED IN CONJUNCTION WITH THIS OPERATOR.
TAKE-UP REEL: Take-up reel should be installed 12"
above the top of the door.
COIL CORD: Connect operator end of coil cord to junction box (not supplied) fastened to the wall approximately halfway up the door opening.
MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE PROCEEDING WITH ADJUSTMENTS.
1. To adjust limit nuts depress retaining plate to allow nut to spin freely. After adjustment, release plate and ensure it seats fully in slots of both nuts.
2. To increase door travel, spin nut away from actuator. To decrease door travel, spin limit nut toward actuator.
3. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening.
4. Repeat Steps 1 and 2 for close cycle. Adjust close limit nut so that actuator is engaged as door fully seats at the floor.
CLOSE Limit Switch
TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS.
If other problems persist, call our toll-free number for assistance - 1-800-528-2806.
WARNING
OPEN Limit Switch
Actuator
SAFETY
(Aux. Close) Limit Switch
8
Retaining Plate
Aux. OPEN Limit Switch
Page 9
9
LGJ LIMIT SWITCH ADJUSTMENT
IMPORTANT NOTE: To avoid danger of possible damage to the door and operator, limit switches must be
adjusted to their approximate positions before applying power to the operator.
NEVER PLACE HANDS OR TOOLS INSIDE OPERATOR OR NEAR MECHANISM UNLESS POWER IS OFF!!
WARNING
A. Set Limit Direction Switch
Open the cover on the electrical enclosure and locate dip switch SW1 on circuit board. The direction of the limit travel is determined by the switch SW1 - pole #2 setting.
If your operator is mounted Motor Side Up:
Set dip switch SW1 - pole #2 to “ON” position.
If your operator is mounted Motor Side Down:
Set dip switch SW1 - pole #2 to “OFF” position.
NOTE: See Mounting Options on page 5 to verify the
correct mounting application.
As determined by SW1 - pole 2 setting above, locate your OPEN and CLOSE limit switches. See the figure below for switch layout.
For Motor Side Up Mounting: Limit switch -A- is the OPEN limit. Limit switch -B- is the CLOSE limit.
For Motor Side Down Mounting: Limit switch -A- is the CLOSE limit. Limit switch -B- is the OPEN limit.
Auxiliary limit switches to control other functions are also present and should not be confused with the -A­and -B- limit switches. There are two(2) limit nuts on the threaded shaft that transverse the shaft as the operator opens and closes the door. When a limit nut nears the end of the shaft, it activates a switch(es).
B. Manually raise the door to a nearly open position. (see page 17, Manual Operation)
C. Depress the limit nut retaining bracket away from the slots in the limit nuts, and manually rotate to the OPEN limit nut until it depresses the OPEN limit switch lever (you can hear the switch click when the switch contacts transfer). Release the retaining bracket and be sure it engages in the slots of both limit nuts.
D. Manually lower the door to a nearly closed position, and repeat step C with the CLOSE (right) limit nut.
E. Test Limit Travel Manually move the door to a half-open position to avoid damage due to incorrect (dip switch setting) limit travel. When power is applied, it will cause the door to OPEN when the limit nuts are traveling in the direction of the CLOSE limit switch or vice versa. In either instance, the limit nuts will travel past the limit switch and may cause damage to both the door and operator. See Step A for correct setting.
F. After completing the wiring connections on pages 11 thru 13, refer back to step C above for adjustment of limit switches to their final, exact position.
Limit Switch -A-
(Top Switch)
Dip Switch
SW1
Limit Switch -B-
(Top Switch)
Limit Nut
Limit Switch -A­(Bottom Switch)
Limit Switch -B-
(Bottom Switch)
If you operator is mounted Motor Side Up: Set dip switch SW1 - pole
#2 to “ON” position
If your operator is mounted Motor Side Down: Set dip switch
SW1 - pole #2 to “OFF” position.
When SW1 - pole 2 position is “ON”: Limit switch -A- is the OPEN
limit. Limit switch -B- is the close limit.
When SW1 - pole 2 position is “OFF”: Limit switch -A- is the
CLOSE limit. Limit Switch -B- is the OPEN limit.
Limit Switch Layout
WARNING
Page 10
NUMBERED BOXES CORRESPOND WITH TERMINALS ON J1 CONNECTOR STRIP If Neccessary, Remove The Connector Block From The Board To Secure Each Wire Connection
Connect field wires to any terminal number shown in the respective column. See control options below for explanation of how field control will function for each terminal number.
OR
OR
OR
11
97 8435
OPEN
CLOSE
STOP
STANDARD
3 BUTTON CONTROL
10 5
SENSING
EDGE
85
9
11
ANY OPEN CONTROL (SEE NOTE)
65
ANY OPEN & CLOSE CONTROL (SEE NOTE)
OR
OR
OR
11
97 8435
OPEN
CLOSE
STOP
OR
OR
OR
11
97 845
OPEN
CLOSE
STOP
OR
OR
OR
11
97 8435
OPEN
CLOSE
STOP
OR
OR 1145
OPEN
OFF ON
CLOSE
2 BUTTON
CONTROL (SEE NOTE)
3 BUTTON CONTROL WITH KEYED LOCK-OUT
3 BUTTON CONTROL
WITH MULTIPLE CONTROL STATIONS
WHEN CONNECTING AN OPEN CONTROL TO:
- Open control will require constant pressure to keep door moving.
- Open control will only require momentary contact and will set or reset timer to close.
- Open control will only require momentary contact and will NOT set or reset timer to close.
WHEN CONNECTING AN CLOSE CONTROL TO:
- Close control will require constant pressure to keep door moving.
- Close control will only require momentary contact. DO NOT add unless using an entrapment Protection device.
11
9
8
4
7
OPEN AND CLOSE CONTROL OPTIONS
IMPORTANT NOTE:
WHEN STOP BUTTON IS NOT USED, ADD A JUMPER FROM TERMINAL 3 TO TERMINAL 5.
3 5
MAXIMUM RUN TIME: 1 - ON: Maximum run time is 90 seconds.
OFF: Maximum run time is 45 seconds.
MAXIMUM RUN TIME: 2 - ON: CLOSE limit switch B
OFF: CLOSE limit switch A
MAXIMUM RUN TIME: 3 - OFF: (DO NOT ADJUST)
4 - OFF: (DO NOT ADJUST) CONSULT FACTORY FOR ADJUSTEMENT
SWITCH #1 SETTINGS
SWITCH #2 SETTINGS
TIMER TO CLOSE SWITCH SETTING:
O = ON F = OFF
1 2 3 4 O O O O F O O O O F O O F F O O O O F O F O F O O F F O F F F O
1 2 3 4 O O O F F O O F O F O F F F O F O O F F F O F F O F F F F F F F
= Disabled = 2 sec = 3 sec = 13 sec = 15 sec = 23 sec = 32.5 sec = 43.6 sec
= 72 sec = 88 sec = 107 sec = 126sec = 148 sec = 172 sec = 198 sec = 224 sec
SETTING SETTINGTIME TIME
SWITCH ADJUSTMENTS
OR
OR

MAINTENANCE SCHEDULE

Check at the intervals listed in the following chart.
EVERY EVERY EVERY
ITEM PROCEDURE 3 MONTHS 6 MONTHS 12 MONTHS
Drive Chain Check for excessive slack.
Sprockets Check set screw tightness
Fasteners Check & tighten as required
Manual Disconnect Check & Operate
Bearings & Shafts Check for wear & lubricate
Use SAE 30 Oil (Never use grease or silicone spray).
Repeat ALL procedures.
Do not lubricate motor. Motor bearings are rated for continuous operation.
Inspect and service whenever a malfunction is observed or suspected.
CAUTION: BEFORE SERVICING, ALWAYS DISCONNECT OPERATOR FROM POWER SUPPLY.
Check & adjust as required. Lubricate.*

HOW TO ORDER REPAIR PARTS
OUR LARGE SERVICE ORGANIZATION
INSTALLATION AND SERVICE INFORMATION
ARE AVAILABLE 6 DAYS A WEEK
CALL OUR TOLL FREE NUMBER - 1-800-528-2806
HOURS 7:00 TO 3:30 p.m. (Mountain Std. Time)
MONDAY Through SATURDAY
SPANS AMERICA
WHEN ORDERING REPAIR PARTS
PLEASE SUPPLY THE FOLLOWING INFORMATION:
PART NUMBER DESCRIPTION MODEL NUMBER
ADDRESS ORDER TO:
THE CHAMBERLAIN GROUP, INC.
Electronic Parts & Service Dept. 2301 N. Forbes Blvd., Suite 104
Tucson, AZ 85745
10
Page 11
11

CONTROL WIRING

Standard C2 or B2 Wiring
Model MGJ operators are shipped from the factory with jumper set for C2 wiring, which requires constant pressure on button to close the door. If momentary contact in close direction is desired (B2 wiring) you must include an entrapment protection device. See close control jumper setting below.
Constant pressure on close (C2 wiring)
Red jumper wire was placed on terminal #2 in the electrical enclosure. The operator will require constant pressure on close control in order to keep door moving in the close direction.
Momentary contact on close (B2 wiring)
Move red jumper wire from terminal #2 to terminal #3. The operator will require only momentary contact to close the door.
LOCATING THE CONTROL STATION
All operators are supplied with some type of control station. Generally a three button station (OPEN/CLOSE/STOP) is provided. A two-position key switch or control station (OPEN/CLOSE) may be added or substituted when requested at the time of order. Mount the control station near the door.
WARNING
INSTALL THE CONTROL STATION WHERE THE DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND ITS HARDWARE. IF CONTROL STATION CANNOT BE INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN THE CONTROL STATION IS USED TO ACTIVATE THE DOOR, A REVERSING
EDGE MUST
BE INSTALLED ON THE BOTTOM OF
THE DOOR. FAILURE TO INSTALL A REVERSING
EDGE UNDER THESE CIRCUMSTANCES MAY RESULT IN SERIOUS INJURY OR DEATH TO PERSONS TRAPPED BENEATH THE DOOR.
IMPORTANT: Mount WARNING NOTICE beside or
below the push button station.
MOUNT WARNING NOTICE
DETERMINE WIRING TYPE
Refer to the wiring diagram located on the inside cover the electrical box to determine the type of control wiring.
SPECIAL CONTROL WIRING
If your operator was shipped from the factory with non-standard control wiring or with optional accessories that require additional instructions, refer to the wiring diagram(s) indicated in the special control wiring data box. When a replacement wiring diagram is present, wiring diagrams in this manual will not apply. Refer only to the replacement wiring diagram for all connections.
IMPORTANT NOTE: If your wiring diagram is missing, or you are unsure of the wiring type for your operator, contact the customer service department @ 1-800-528-2806.
MODEL MGJ
Standard G2 Wiring
Model LGJ operators are supplied with type G2 control wiring. Study the control features list below to determine the features and type of control equipment that may be used with your operator.
Entry Controls:
OPEN control requiring maintained contact. OPEN control requiring only momentary contact. CLOSE control requiring maintained contact. CLOSE control requiring only momentary contact. OPEN/CLOSE single control requiring momentary contact.. STOP control requiring momentary contact.
Safety Devices:
External Interlock switch to disable all control pneumatic safety (N.C.) to STOP while closing Safety Device to REVERSE while closing Door Lock Sensing Circuit.
Operational Features:
REVERSE (if closing) with momentary contact on OPEN. AUTOMATIC TIMER to CLOSE from any device. AUTOMATIC TIMER to CLOSE from selected devices. DELAY REVERSE in either direction for 1 second. STOP after maximum run time is exceeded.
Note:
Refer to LGJ control connection diagrams on page 15.
MODEL LGJ
WARNING
Control Station
OPEN
Push
Buttons
CLOSE
STOP
WARNING
TO PREVENT ENTRAPMENT
DO NOT START DOOR DOWNWARD
UNLESS DOORWAY IS CLEAR
WARNING Notice
Page 12
(OPTIONAL)
SINGLE PHASE SCHEMATIC DIAGRAM for MGJ
1754
BK
(HOT) L2
BK
3
(OPTIONAL)
LIGHT
W
MAX.
100W
WIRE NUT
CLOSE-B
C
N.O.
W
BK
OPEN-A
CAPACITOR
R
STOP
MOVE JUMPER WIRE TO TERMINAL #2 FOR MOMENTARY CONTACT ON CLOSE
4
C
BL
BIMETAL
RELAY
RES.
Y
Y
B
A
Y
W
MOTOR *
Y
BK
O/L
R
PR1.
10VA.
24VAC.
SEC.
R
L1 (N)
BR
W
Y/BK
WIRE NUT
R3
BR
OPEN
SAFETY
EDGE
10
GY
PULL SWITCH
TO
OPEN & CLOSE
7
CLOSE
BR
R1
AUX.
CLOSE L/S
GY
Y
R2
Y
OR
GY
BL
OPEN-B
1
OR
AUX.
OPEN
L/S
P
2
12
OR
P
CLOSE-A
BL
C
OP
CL
N.O.
R
OPEN L.S.
OR
N.C.
CLOSE L/S
P
N.C.
11
W
C
W
W
C
* TO REVERSE MOTOR ROTATION INTERCHANGE
RED AND YELLOW MOTOR WIRES.
12
Page 13
13
THREE PHASE SCHEMATIC DIAGRAM for MGJ
1819
(YEL)
3 PHASE
POWER IN
3
STOP
OPEN
BRN
GY
PUR YEL
BRN
1 2 3
7 85 9
230 VOLT - 3 PHASE
MOTOR CONNECTION
L3
L2
L1
(BK)
(BK)
(BK)
EXTERNAL
INTERLOCK
45
4
6
(BR)
BL/BK
O/L
BL/BK
*
230V BRAKE
(WHEN PRESENT)
(BRN)
(YEL)
14
(OR)
13
1
BRN
GY
PUR YEL
BRN
1 2 3
460 VOLT - 3 PHASE
MOTOR CONNECTION
CL
OP
OP
CL
3
3
1
5
OVERLOAD (IN MOTOR)
(OR)
A1
4
4
2
6
OP
7
4 85 9
6
OP
BL/BK
O/L
BL/BK
(OR)
A2
*
230V BRAKE
(WHEN PRESENT)
OP
CL
6
2
5
1
(BK)
PRI.
(BRN)
24VAC
SEC.
OPEN
LIMIT SWITCH
C
NC
(GY)
(PUR)
(YEL)
(BK)
(SEE NOTE #1)
T1
(YEL)
(OR)
WIRE
TO MOTOR
NUT
SAFETY EDGE
R1
(OR)
(OR)
OPEN & CLOSE
RADIO TO
(OR)
OPEN & CLOSE
R1
R2
CLOSE
(RED)
NOTE:
1. Voltage same as line voltage.
10
7
(YEL)
AUX. CLOSE
LIMIT SWITCH
(GY)
NC
(YEL)
(GY)
C
(OR)
NC
(RED)
R1
AUX. OPEN
LIMIT SWITCH
C
NO
(PUR)
2
(PUR)
14
13
(RED)
CLOSE CONTROL WIRING OPTIONS
C2 WIRING - Constant Presssure to Close
*
RED WIRE ON TERMINAL #2 (Shipped from Factory)
R1
(PUR) (PUR) (PUR)
CL
A2 A1
CL
- Shipped from Factory
*
B2 WIRING - Momentary Contact to Close MOVE RED WIRE FROM TERMINAL #2 TO TERMINAL #3
(RED)
CLOSE
LIMIT SWITCH
NC
R3
(RED)
(PUR)
C
Page 14
SINGLE PHASE SCHEMATIC DIAGRAM for LGJ
WARNING
1666
14
Page 15
15
LGJ CONTROL CONNECTION DIAGRAM
NUMBERED BOXES CORRESPOND WITH TERMINALS ON J1 CONNECTOR STRIP If Neccessary, Remove The Connector Block From The Board To Secure Each Wire Connection
Connect field wires to any terminal number shown in the respective column. See control options below for explanation of how field control will function for each terminal number.
OR
OR
OR
11
97 8435
OPEN
CLOSE
STOP
STANDARD
3 BUTTON CONTROL
10 5
SENSING
EDGE
85
9
11
ANY OPEN CONTROL (SEE NOTE)
65
ANY OPEN & CLOSE CONTROL (SEE NOTE)
OR
OR
OR
11
97 8435
OPEN
CLOSE
STOP
OR
OR
OR
11
97 845
OPEN
CLOSE
STOP
OR
OR
OR
11
97 8435
OPEN
CLOSE
STOP
OR
OR 1145
OPEN
OFF ON
CLOSE
2 BUTTON
CONTROL (SEE NOTE)
3 BUTTON CONTROL WITH KEYED LOCK-OUT
3 BUTTON CONTROL
WITH MULTIPLE CONTROL STATIONS
WHEN CONNECTING AN OPEN CONTROL TO:
- Open control will require constant pressure to keep door moving.
- Open control will only require momentary contact and will set or reset timer to close.
- Open control will only require momentary contact and will NOT set or reset timer to close.
WHEN CONNECTING AN CLOSE CONTROL TO:
- Close control will require constant pressure to keep door moving.
- Close control will only require momentary contact. DO NOT add unless using an entrapment Protection device.
11
9
8
4
7
OPEN AND CLOSE CONTROL OPTIONS
IMPORTANT NOTE:
WHEN STOP BUTTON IS NOT USED, ADD A JUMPER FROM TERMINAL 3 TO TERMINAL 5.
3 5
MAXIMUM RUN TIME: 1 - ON: Maximum run time is 90 seconds.
OFF: Maximum run time is 45 seconds.
MAXIMUM RUN TIME: 2 - ON: CLOSE limit switch B
OFF: CLOSE limit switch A
MAXIMUM RUN TIME: 3 - OFF: (DO NOT ADJUST)
4 - OFF: (DO NOT ADJUST) CONSULT FACTORY FOR ADJUSTEMENT
SWITCH #1 SETTINGS
SWITCH #2 SETTINGS
TIMER TO CLOSE SWITCH SETTING:
O = ON F = OFF
1 2 3 4 O O O O F O O O O F O O F F O O O O F O F O F O O F F O F F F O
1 2 3 4 O O O F F O O F O F O F F F O F O O F F F O F F O F F F F F F F
= Disabled = 2 sec = 3 sec = 13 sec = 15 sec = 23 sec = 32.5 sec = 43.6 sec
= 72 sec = 88 sec = 107 sec = 126sec = 148 sec = 172 sec = 198 sec = 224 sec
SETTING SETTINGTIME TIME
SWITCH ADJUSTMENTS
OR
OR
41B6
LISTED DOOR OPERATOR
Page 16

REPLACEMENT PART KITS LGJ

WARNING
Below are replacement kits available for your operator. Optional modifications and/or accessories included with your operator may add or remove certain components from these lists. Please consult a parts and service representative regarding availability of individual components of kits specified below. Refer to page 10 for all repair part ordering information.
Complete Electrical Box Replacement Kit
K-LGJ2511 Model LGJ2511
Electrical Box Sub-Assembly Kits
K72-12581 LGJ Limit Shaft Assembly K75-12582 LGJ Limit Switch Assembly K79-11384 LGJ PC Board Assembly
K72-12581 LIMIT SHAFT ASSEMBLY KIT
Item
L1
11-11425
L2
12-10458
L3
13-10024
L4
15-48B07AXX
L5
81-11443
L6
80-10053
L7
80-10025
L8
80-10026
L9
86-RP04-012
L10
87-E-038
P/N
Description
Limit Shaft
3/8” Bearing, Plastic Flange
Limit Nut
Sprocket, 48B07
Rotor for RSL Assembly
Washer, Shim
Washer, Shim
Washer, Shim
Roll Pin, 1/8” Dia. x 3/4” Long
E Ring, 3/8”
K75-12582 LIMIT SWITCH ASSEMBLY KIT
Item
S1
S2
S3
S4
S5
S6
S7
S8
P/N
10-11391
18-10036
23-10041
23-11442
80-11445
82-PX04-16
82-PX06-16
84-LH-06
Description
Depress Plate
Spring, Depress Plate
Limit Switch
Limit Switch
Standoff, #4-40 Threaded x .19 Long
Screw, #4-40 x 1” Pan Head Ph
Screw, #6-32 x 1” Pan Head Ph
Locknut #6-32
Qty
1
2
2
1
1
1
1
1
1
3
Qty
1
2
2
2
4
4
2
2
Motor Kit
K20-1025C1 Model LGJ2511
Disconnect Assembly Kit
K75-12583 Model LGJ2511
COMPLETE ELECTRICAL BOX KITS
Item P/N Description QTY
1
10-11390M1
2
10-11392M1
3
21-13395
4
29-7642
5
42-9306
6
42-13378
7
75-11395
8
79-11378
9
80-10027
L1
11-11425
L2
12-10458
L3
13-10024
L4
15-48B07AXX
L5
81-11443
L6
85-FW-38
L7
86-RP04-012
L8
87-E-038
S1
10-11391
S2
18-10036
S3
23-10041
S4
23-11442
S5
80-11446
S6
82-PX04-16
S7
82-PX06-16
S8
84-LH-06
Electrical Box Cover Electrical Box Transformer, LGJ 115V-24VAC Capacitor 220V 42MFD Terminal Block 6 Pole J2 Terminal Block, 16 Pole (1-16) Hall Effect Assembly PCB Board Assembly PCB Board Standoff Limit Shaft 3/8” Bearing, Plastic Flange Limit Nut Sprocket, 48B07 Rotor for RSL Assembly Flat Washer, 3/8” Roll Pin, 1/8” Dia. x 3/4” Long E Ring, 3/8” Depress Plate Spring, Depress Plate Limit Switch Limit Switch
Standoff, #4-40 Threaded x .19 Long Screw, #4-40 x 1” Pan Head Ph Screw, #6-32 x 1” Pan Head Ph Locknut #6-32
1 1 1 1 1 1 1 1 4 1 2 2 1 1 4 1 1 1 2 2 2 4 4 2 2
16
Page 17
WARNING
17
LGJ ELECTRICAL BOX - ILLUSTRATED PARTS
1
L3
L1
L5
L9
L3
7
L10
L7
L2
4
3
S2
S8
S3
S5
S4
S6
S1
2
5
9
8
S7
L2
L6
L4
6
L10
L10
L8
Page 18
REPLACEMENT PART LISTS – MODEL LGJ
WARNING
CAUTION
WARNING
WARNING
Refer to the parts lists below for replacement kits available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists. Individual components of each kit may not be available. Please consult a parts and service representative regarding availability of individual components. Refer to page 10 for all repair part ordering information.
K75-12583 DISCONNECT ASSEMBLY KIT
ITEM PART # DESCRIPTION QTY
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
10-11023
10-11393
10-11394
10-11399
11-11424
15-11379
18-11427
80-207-19
82-HX10-08T
85-FW-75
86-CP04-112
86-RP04-100
87-E-075
Bevel Gear Yoke
Disconnect
Release Lever
Retaining Plate
Disconnect Shaft
Sprocket, 48B14/41B14
Compression Spring
Key, 1/4 x 1-1/2” Long
Screw, #10-32 x 1/2” Hex
Flatwasher, 3/4”
Cotter Pin 1/8” x 1-3/4” Long
Roll Pin, 1/8” Dia. x 1” Long
E Ring 3/4”
1
1
1
1
1
1
1
1
5
1
1
1
1
INDIVIDUAL PARTS
ITEM PART # DESCRIPTION QTY
1
10-11397
2
10-11389-1
3
10-11398-2
4
32-11435
5
See Page 16
6
See Page 16
7
84-FN-10
8
84-FN-19144
Support Bracket
Mounting Bracket (LH)
Mounting Bracket (RH)
Gear Reducer, 40:1
Electrical Box
Motor
Nut
Stud
1
1
1
1
1
1
1
1
18
Page 19
19
LGJ ILLUSTRATED PARTS
D3
5
2
1
D5
D11
D12
D1
4
6
D10
D7
D2
D9
3
D8
D6
D13
D4
D9
7
8
Page 20

REPLACEMENT PART KITS MGJ

Below are replacement kits available for your operator. For replacement of electrical box, motor or brake components be sure to match model number of your unit to kit number below to ensure proper voltage requirements. Optional modifications and/or accessories included with your operator may add or remove certain components from these lists. Please consult a parts and service representative regarding availability of individual components of kits specified below. Refer to page 10 for all repair part ordering information.
Complete Electrical Box Replacement Kits
K-MGJ5011L Model MGJ5011L K-MGJ5023L Model MGJ5023L K-MGJ5025L Model MGJ5025L K-MGJ5038L Model MGJ5038L K-MGJ5043L Model MGJ5043L
K-MGJ5011R Model MGJ5011R K-MGJ5023R Model MGJ5023R K-MGJ5025R Model MGJ5025R K-MGJ5038R Model MGJ5038R K-MGJ5043R Model MGJ5043R
Electrical Box Sub-Assemblies
K72-12565 MGJ Limit Shaft Assembly K75-12566 MGJ Limit Switch Assembly
COMPLETE ELECTRICAL BOX KITS
Item
1
03- 11112
2
10-11403
3
10-11420
4
10-11421
5
(See Var. Comp.)
6
24-24-1
7
29-10338
8
29-2
9
42-10040
10
42-110
L1
11-11373
L2
12-10458
L3
13-10024
L4
15-48B07AXX
L5
80-10026
L6
85-FW-38
L7
86-RP04-012
L8
87-E-038
S1
10-11419
S2
18-10036
S3
23-10041
S4
31-13062
S5
82-PX06-16
S6
82-PX06-19
S7
84-DT-06
S8
84-LH-06
P/N
Description
Reversing Contactor (See Notes) Electrical Box Cover Electrical Box Capacitor Clamp (See Notes) Transformer 24V DPDT Relay Capacitor, 7MFD (See Notes) Resistor, 20 Ohm Terminal Block Assy, 3 Lug 10 Position Terminal Block MGJ Limit Shaft 3/8” Bearing, Plastic Flange Limit Nut Sprocket, 48B07 Washer, Shim 3/8” I.D. x .01 Flatwasher, 3/8” Roll Pin, 1/8” Dia. x 3/4” Long E Ring, 3/8” Depress Plate Spring, Depress Plate SPDT Limit Switch Spacer, .115” ID x 5/8” Long Screw, #6-32 x 1” Pan HD PH Screw, #6-32 x 1-3/8” Pan HD PH Nut, #6-32 Double Tinnerman Locknut #6-32
Qty
1 1 1 1 1 2 1 1 1 1 1 2 2 1 1 2 1 1 1 2 4 8 2 8 4 2
Motor Kits
K20-1050C1M Model MGJ5011 K20-3050C4M Models MGJ5023,MGJ5038,MGJ5043 K20-5150C6M Model MGJ5025
Disconnect Assembly Kit
K75-12567 Model MGJ Operators
K72-12565 LIMIT SHAFT ASSEMBLY KIT
Item
L1
11-11373
L2
12-10458
L3
13-10024
L4
15-48B07AXX
L5
80-10026
L6
85-FW-38
L7
86-RP04-012
L8
87-E-038
P/N
Description
MGJ Limit Shaft 3/8” Bearing, Plastic Flange Limit Nut Sprocket, 48B07 Washer, Shim 3/8” I.D. x .01 Flatwasher, 3/8” Roll Pin, 1/8” Dia. x 3/4” Long E Ring, 3/8”
K75-12566 LIMIT SWITCH ASSEMBLY KIT
Item
S1 S2 S3 S4 S5 S6 S7 S8
P/N
10-11419 18-10036 23-10041 31-13062 82-PX06-16 82-PX04-20 84-DT-06 84-LH-06
Description
Depress Plate Spring, Depress Plate SPDT Limit Switch Spacer, .115” ID x 5/8” Long Screw, #6-32 x 1” Pan HD PH Screw, #4-40 x 1-1/2” Pan HD PH Nut, #6-32 Double Tinnerman Locknut #6-32
VARIABLE COMPONENT KITS
MGJ5011
Item
5
P/N
21-5115 21-5230 21-5460
Description
Transformer, 115V Transformer, 230V Transformer, 460V
MGJ5023
NOTES:
1) Reversing Contactor (03-11112), Used only on three phase operators. Single phase operators use relays.
2) Capacitor (29-10338), Capacitor Clamp (10-11421) and Resistor (29-2) used only on single phase operators.
Qty
1 2 2 1 1 2 1 1
Qty
1 2 4 8 2 8 4 2
MGJ5043
MGJ5025
MGJ5038
20
Page 21
21
MGJ ELECTRICAL BOX - ILLUSTRATED PARTS
L8
L6
L2
1
L3
L1
L7
L2
4
7
3
9
S3
S9
S7
S4
S6
S3
S5
6
6
8
5
S2
S8
S1
2
S3
S7
S6
S4
S3
10
L3
L4
L5
Page 22
WARNING
CAUTION
WARNING
WARNING
WARNING
REPLACEMENT PART LISTS – MODEL MGJ
Refer to the parts lists below for replacement kits available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists. Individual components of each kit may not be available. Please consult a parts and service representative regarding availability of individual components. Refer to page 10 for all repair part ordering information.
K75-12567 DISCONNECT ASSEMBLY KIT
ITEM PART # DESCRIPTION QTY
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
D14
D15
07-11418
10-11023
10-11358
10-11394
11-11361
15-11377
18-10467
19-8A-12
80-11416
80-206-11
82-SH10-12
85-LS-10
86-CP04-112
86-RP04-100
87-E-100
Disconnect Hub
Bevel Gear Yoke
Disconnect Support Bracket
Release Lever
Disconnect Shaft MGJ
Sprocket, 41B19 x 1.25 Bore
Compression Spring
12ft. Of Sash Chain
Disconnect Key 1/4 x 1/4 x 7/8
Washer, 1” I.D. x 1/16” Thick
Screw, #10-32 Hex Head Socket
#10 Lock Washer ZP
Cotter Pin, 1/8” x 1-3/4” Long
Roll Pin, 1/8” Dia. x 1” Long
E Ring, 1” Plated
1
1
1
1
1
1
1
1
2
1
2
2
4
1
2
INDIVIDUAL PARTS
ITEM PART # DESCRIPTION QTY
1
10-11357
2
10-11359
3
32-11414
4
See Page 20
5
See Page 20
Brake Mounting Plate
Front Bracket
Gear Reducer, 45:1
Electrical Box
Motor
1
1
1
1
1
22
Page 23
23
ILLUSTRATED PARTS – MODEL MGJ
D8
D13
4
5
1
3
D10
D9
D7
D1
D15
D6
D15
D3
D4
D5
D13
D2
D12
D14
D11
2
Page 24
LISTED DOOR OPERATOR
MGJ CONTROL CONNECTION DIAGRAM
OPEN TIMER TO CLOSE
3 BUTTON STATION or 3 POSITION KEYSWITCH w/ SPRING RETURN TO CENTER AND STOP BUTTON
2 OR MORE KEY LOCKOUT
R1
R2
R3
1 2 3 4
Stop
Close
Open
Stop
Close
Open
1 2 3 4
Stop
Close
Open
2 BUTTON STATION or 3 POSITION KEYSWITCH w/ SPRING RETURN TO CENTER
STANDARD
1 2 4
Close
Open
ALL CONTROL WIRING TYPES
2 OR MORE
1 2 4
Close
Open
Close
Open
OPEN / CLOSE
3
7
RADIO CONTROL
1 BUTTON STATION or
ANY AUXILIARY DEVICE
RESIDENTIAL RADIO CONTROLS
SENSING DEVICE TO REVERSE OR STOP
EXTERNAL INTERLOCK
3
10
4
5
4
5
Remove Jumper
When Interlock is Used
ONE 2 OR MORE
STANDARD
1 2 3 4
Stop
Close
Open
IMPORTANT NOTES:
1) The 3-Button Control Station provided must be connected for operation.
2) If a STOP button is not used, a jumper must be placed between termianls 3 and 4.
3) Auxiliary control equipment may be any normally open two wire device such as pullswitch, single button, loop detector, card key or such device.
Keyswitch
Sensing Device
ALL CONTROL WIRING TYPES
B2 or T1
WIRING TYPES ONLY
ALL CONTROL WIRING TYPES
T1 WIRING - RADIO TO OPEN ONLY
*
*
EXTERNAL
TERMINAL BLOCK
ALL CONTROL WIRING TYPESALL CONTROL WIRING TYPES
ALL CONTROL WIRING TYPES
TIMER TO CLOSE w/ WARNING LIGHT
ALL CONTROL WIRING TYPEST1 CONTROL WIRING ONLY
11
12
Timer Defeat
Switch
13
14
Power Supply for
Warning Light
Auxiliary Terminal Block
Warning Light will activate 15 sec. before door closes.
ALL CONTROL WIRING TYPES
ATTENTION ELECTRICIAN:
USE 16 GAUGE OR HEAVIER WIRE
FOR ALL CONTROL CIRCUIT WIRING.
SEE NOTE #2SEE NOTE #2 SEE NOTES
#2 AND #3
(Refer to page 15 for model LGJ control connections)
01-11452H
c
2003, The Chamberlain Group, Inc.
All rights Reserved
Loading...