DISCONNECT :.......................Floor level disconnect for
emergency manual door operation.
REVERSING EDGE: ...............(Optional) Electric or
pneumatic sensing device attached to the bottom edge
of door
A REVERSING EDGE IS STRONGLY RECOMMENDED
FOR ALL COMMERCIAL OPERATOR INSTALLATIONS.
REQUIRED WHEN THE 3 BUTTON CONTROL STATION
IS OUT OF SIGHT OF DOOR OR ANY OTHER
CONTROL (AUTOMATIC OR MANUAL) IS USED.
MGJ WEIGHTS AND DIMENSIONS
HANGING WEIGHT:..........80-110 LBS.
7.50”
11.05”
7.00”
9.25”
LGJ WEIGHTS AND DIMENSIONS
HANGING WEIGHT:..........80-110 LBS.
7.90”
10.50”
11.00”
3.00”
MOUNTING DIMENSIONS
5.50”
4.75”
.98”
1.96”
4.50”
2.25”
8.90”
1.97”
MOUNTING DIMENSIONS
10.88”
2
Page 3
3
TO AVOID DAMAGE TO DOOR AND OPERATOR,
MAKE ALL DOOR LOCKS INOPERATIVE. SECURE
LOCK(S) IN "OPEN" POSITION.
IF THE DOOR LOCK NEEDS TO REMAIN
FUNCTIONAL, INSTALL AN INTERLOCK SWITCH.
DO NOT CONNECT ELECTRIC POWER UNTIL
INSTRUCTED TO DO SO.
KEEP DOOR BALANCED. STICKING OR BINDING
DOORS MUST BE REPAIRED. DOORS, DOOR
SPRINGS, CABLES, PULLEYS, BRACKETS AND
THEIR HARDWARE MAY BE UNDER EXTREME
TENSION AND CAN CAUSE SERIOUS PERSONAL
INJURY. CALL A PROFESSIONAL DOOR
SERVICEMAN TO MOVE OR ADJUST DOOR
SPRINGS OR HARDWARE.
WARNING
CAUTION
WARNING
WARNING
WARNING
SITE PREPARATIONS
It is imperative that the wall or mounting surface provide
adequate support for the operator.
This surface must:
a) Be rigid to prevent play between operator and
door shaft.
b) Provide a level base.
c) Permit the operator to be fastened securely and
with the drive shaft parallel to the door shaft.
The safety and wear of the operator will be adversely affected
if any of the above requirements are not met.
For metal buildings, fasten 2” x 2” x 3/16” (or larger) angle
iron frames to the building purlins. For proper spacing, retain
.2.75” between for model MGJ, butt purlins together for model
LGJ. See Figure 1.
OPERATOR PREPARATION
IMPORTANT SAFETY NOTES
2.75 for MGJ, butt together for LGJ
Model LGJ:Shipped from the factory for right hand mounting, refer to preparation instructions on page 4 for
Left hand mounting.
Model MGJ:Shipped from the factory for either left hand or right hand mounting. Refer to the last digit in the
model number for handing of your unit. If necessary, model MGJ may also be field modified to
accommodate opposite handing. Refer to the conversion instructions below and on page 4.
KEYS
SPRING
DISC
HUB
E RING
SPROCKET
YOKE
BRACKET
SHAFT
DISC
LEVER
MGJ OPPOSITE HANDING PREPARATIONS
1. Remove Disconnect Assembly Components
Remove the master link from the limit chain, remove
the chain and set it aside.
Remove the two E Rings securing the sprocket on the
gear reducer shaft. Remove the screws securing the
yoke to the disconnect shaft, set the yoke aside.
CAUTION
WARNING
Shaft Support Bracket
with Bearing (Not Supplied)
Door Sprocket
2-1/4"
FIGURE 1
Page 4
Remove the three cotter pins from the disconnect shaft.
Do not discard the pins. Slide the disconnect shaft out
of the support bracket. The release lever will now be
free inside the motor frame. Remove the release lever
and sash chain from the motor frame. Slide the
disconnect hub, compression spring, and flatwasher
2. Re-assemble Disconnect Assembly
Remove the two screws on the opposite side of the gear
reducer and mount the disconnect support bracket with
the notched side facing the motor. For the remainder of
the installation, follow the steps outlined above in
reverse order, referring to the illustration as necessary.
from the end of the gear reducer shaft. Remove the
disconnect support bracket by first removing the the two
gear reducer housing screws. Replace the screws in the
gear reducer and firmly tighten.
LGJ LEFT HAND MOUNTING PREPARATIONS
LGJ Operators are assembled at the factory to be installed in a right hand (motor side up) configuration. To install an
LGJ Operator on the left hand side of your door (motor side down), complete the three steps described below.
1. Reconfigure Disconnect Chain Assembly
The default configuration for the disconnect chain assembly
is shown in Figure 1. This configuration allows the chain to
hang freely when the operator is mounted on right side only.
To insure smooth operation of the disconnect chain
assembly when mounted motor side down, reconfigure as
described below and as shown in figures 2 and 3.
1. Disconnect the key ring from the release cable.
2. Thread the release cable through the slot on the
outermost edge of the support bracket, as shown in Figure
2.
3. Re-attach the key ring and sash chain to the end of the
loop of release cable.
FIGURE 1
HOUR GLASS
CABLE SLEEVE
2. Set Limit Switch Direction
Locate Switch #1 on PCB in the electrical box. Place
pole #2 of Switch #1 in the “OFF” position. With this
setting limit switch labeled “A” is the close switch, limit
switch labeled “B” is the open switch.
IMPORTANT: Refer to page 9 for for complete
instructions on setting of limit switches.
3. Affix Electrical Box Cover Caution Label
Place the caution label on electrical box cover such that
the text is read in the opposite direction of silkscreen.
SLOT
RELEASE
CABLE
SUPPORT
BRACKET
KEY RING
SASH CHAIN
Disconnect Cable as shipped from the factory
4
Page 5
5
FIGURE 3
LABEL
SILK
SCREEN
HOUR GLASS
CABLE SLEEVE
RELEASE
CABLE
SUPPORT
BRACKET
SLOT
SASH CHAIN
KEY RING
FIGURE 2
Disconnect Cable Re-routed for Left Hand Mounting
Page 6
OPERATOR MOUNTING
Before your operator is installed, be sure the door has been properly aligned and is working smoothly. The
operator may be wall mounted or mounted on a bracket or shelf. If necessary, refer to the operator preparations
on page 3. Refer to the illustration and instructions below that suits your application.
1a. Wall Mounting
The operator should generally be installed below
the door shaft, and as close to the door as
possible. The optimum distance between the door
shaft and operator drive shaft is between 12” - 15”.
Refer to Figure 3.
1b. Bracket or Shelf Mounting
The operator may be mounted either above or
below the door shaft. The optimum distance
between the door shaft and operator drive shaft is
between 12” - 15”. Refer to Figure 4.
OPTIONAL (LGJ)Mounting Bracket
OPTIONAL (MGJ)
Mounting Bracket
P/N 10-9098
Typical Right Hand
Wall Mounted Operator
1c. Place door sprocket on the door shaft. Do not
insert the key at this time.
2. Wrap drive chain around door sprocket and join
roller chain ends together with master link.
3. Raise operator to approximate mounting position
and position chain over operator sprocket.
4. Raise or lower operator until the chain is slightly
taut (not tight). Make sure the operator output
shaft is parallel to door shaft and sprockets are
aligned. When in position, secure the operator to
wall or mounting bracket.
5. Align sprockets and secure, (see Figure 5).
IMPORTANT: The shelf or bracket must
provide adequate support, prevent play
between operator and door shaft, and permit
operator to be fastened securely and with the
drive shaft parallel to the door shaft.
FIGURE 4FIGURE 3
Be sure door
sprocket is properly
aligned with drive
before securing to
the shaft.
Chain Keeper
6
FIGURE 5
Page 7
7
EMERGENCY MANUAL OPERATION
This operator a floor level disconnect chain to
disconnect the door from the door operator allowing
for manual operation of the door in case of
emergency or power failure.
1. To disengage, pull the chain and secure in the
disengaged position by slipping the end through the
keyhole bracket mounted on the wall. Or if
emergency egress device is used, pull handle to
disengage operator from door.
2. The door may now be pushed up or pulled down
manually. Release the disconnect chain to operate the
door again electrically.
Keyhole Bracket
6. Mount Chain Keeper / Keyhole Bracket
Using suitable hardware mount the chain keeper
approximately 4 feet above the floor, near the free
hanging chain. Remove disconnect sash chain
from bag and place the end through the keyhole
in the the chain keeper. Remove excess links if
necessary.
TURN OFF POWER TO THE OPERATOR BEFORE
MANUALLY OPERATING YOUR DOOR.
WARNING
CAUTION
WARNING
WARNING
Pull sash chain and secure
in bracket for manual
operation of the door.
CAUTION
Page 8
WARNING
ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL)
SENSING EDGES
All types of sensing edges with an isolated normally
open (N.O.) output are compatible with your operator.
This includes pneumatic and electric edges. If your
door does not have a bottom sensing edge and you
wish to purchase one, contact the supplier of your
operator.
If not pre-installed by the door manufacturer, mount the
sensing edge on the door according to the instructions
provided with the edge. The sensing edge may be
electrically connected by either coiled cord or take-up
reel. Refer to the steps below
Important Notes:
a) Proceed with Limit Switch Adjustments before
making any sensing edge wiring connections to
operator as described below.
b) Electrician must hardwire the junction box to the
operator electrical box in accordance with local
codes.
MGJ LIMIT SWITCH ADJUSTMENT
IT IS STRONGLY RECOMMENDED THAT A
SENSING EDGE OR OTHER ENTRAPMENT
PROTECTION DEVICE BE USED IN
CONJUNCTION WITH THIS OPERATOR.
TAKE-UP REEL: Take-up reel should be installed 12"
above the top of the door.
COIL CORD: Connect operator end of coil cord to
junction box (not supplied) fastened to the wall
approximately halfway up the door opening.
MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE
PROCEEDING WITH ADJUSTMENTS.
1. To adjust limit nuts depress retaining plate to allow
nut to spin freely. After adjustment, release plate
and ensure it seats fully in slots of both nuts.
2. To increase door travel, spin nut away from
actuator. To decrease door travel, spin limit nut
toward actuator.
3. Adjust open limit nut so that door will stop in open
position with the bottom of the door even with top
of door opening.
4. Repeat Steps 1 and 2 for close cycle. Adjust close
limit nut so that actuator is engaged as door fully
seats at the floor.
CLOSE Limit Switch
TO AVOID SERIOUS PERSONAL INJURY OR DEATH
FROM ELECTROCUTION, DISCONNECT ELECTRIC
POWER BEFORE MANUALLY MOVING LIMIT NUTS.
If other problems persist, call our toll-free number for
assistance - 1-800-528-2806.
WARNING
OPEN Limit Switch
Actuator
SAFETY
(Aux. Close) Limit Switch
8
Retaining Plate
Aux. OPEN Limit Switch
Page 9
9
LGJ LIMIT SWITCH ADJUSTMENT
IMPORTANT NOTE: To avoid danger of possible damage to the door and operator, limit switches must be
adjusted to their approximate positions before applying power to the operator.
NEVER PLACE HANDS OR TOOLS INSIDE
OPERATOR OR NEAR MECHANISM UNLESS
POWER IS OFF!!
WARNING
A. Set Limit Direction Switch
Open the cover on the electrical enclosure and locate
dip switch SW1 on circuit board. The direction of the
limit travel is determined by the switch SW1 - pole #2
setting.
If your operator is mounted Motor Side Up:
Set dip switch SW1 - pole #2 to “ON” position.
If your operator is mounted Motor Side Down:
Set dip switch SW1 - pole #2 to “OFF” position.
NOTE: See Mounting Options on page 5 to verify the
correct mounting application.
As determined by SW1 - pole 2 setting above, locate
your OPEN and CLOSE limit switches. See the figure
below for switch layout.
For Motor Side Up Mounting: Limit switch -A- is the
OPEN limit. Limit switch -B- is the CLOSE limit.
For Motor Side Down Mounting: Limit switch -A- is
the CLOSE limit. Limit switch -B- is the OPEN limit.
Auxiliary limit switches to control other functions are
also present and should not be confused with the -Aand -B- limit switches. There are two(2) limit nuts on
the threaded shaft that transverse the shaft as the
operator opens and closes the door. When a limit nut
nears the end of the shaft, it activates a switch(es).
B. Manually raise the door to a nearly open position.
(see page 17, Manual Operation)
C. Depress the limit nut retaining bracket away from
the slots in the limit nuts, and manually rotate to the
OPEN limit nut until it depresses the OPEN limit
switch lever (you can hear the switch click when the
switch contacts transfer). Release the retaining
bracket and be sure it engages in the slots of both
limit nuts.
D. Manually lower the door to a nearly closed
position, and repeat step C with the CLOSE (right)
limit nut.
E. Test Limit Travel
Manually move the door to a half-open position to
avoid damage due to incorrect (dip switch setting)
limit travel. When power is applied, it will cause the
door to OPEN when the limit nuts are traveling in the
direction of the CLOSE limit switch or vice versa. In
either instance, the limit nuts will travel past the limit
switch and may cause damage to both the door and
operator. See Step A for correct setting.
F. After completing the wiring connections on pages
11 thru 13, refer back to step C above for adjustment
of limit switches to their final, exact position.
Limit Switch -A-
(Top Switch)
Dip Switch
SW1
Limit Switch -B-
(Top Switch)
Limit Nut
Limit Switch -A(Bottom Switch)
Limit Switch -B-
(Bottom Switch)
If you operator is mounted Motor
Side Up: Set dip switch SW1 - pole
#2 to “ON” position
If your operator is mounted
Motor Side Down: Set dip switch
SW1 - pole #2 to “OFF” position.
When SW1 - pole 2 position is
“ON”: Limit switch -A- is the OPEN
limit. Limit switch -B- is the close
limit.
When SW1 - pole 2 position is
“OFF”: Limit switch -A- is the
CLOSE limit. Limit Switch -B- is the
OPEN limit.
Limit Switch Layout
WARNING
Page 10
NUMBERED BOXES CORRESPOND WITH TERMINALS ON J1 CONNECTOR STRIPIf Neccessary, Remove The Connector Block From The Board To Secure Each Wire Connection
Connect field wires to any terminal number shown in the respective column. See control options below for explanation of how field control will function for each terminal number.
OR
OR
OR
11
978435
OPEN
CLOSE
STOP
STANDARD
3 BUTTON CONTROL
105
SENSING
EDGE
85
9
11
ANY OPEN CONTROL (SEE NOTE)
65
ANYOPEN & CLOSE CONTROL (SEE NOTE)
OR
OR
OR
11
978435
OPEN
CLOSE
STOP
OR
OR
OR
11
97845
OPEN
CLOSE
STOP
OR
OR
OR
11
978435
OPEN
CLOSE
STOP
OR
OR1145
OPEN
OFFON
CLOSE
2 BUTTON
CONTROL (SEE NOTE)
3 BUTTON CONTROL WITH KEYED LOCK-OUT
3 BUTTON CONTROL
WITHMULTIPLE CONTROL STATIONS
WHEN CONNECTING AN OPEN CONTROL TO:
- Open control will require constant pressure to keep door moving.
- Open control will only require momentary contact and will set or reset timer to close.
- Open control will only require momentary contact and will NOT set or reset timer to close.
WHEN CONNECTING AN CLOSE CONTROL TO:
- Close control will require constant pressure to keep door moving.
- Close control will only require momentary contact. DO NOT add unless using an entrapment Protection device.
11
9
8
4
7
OPEN AND CLOSE CONTROL OPTIONS
IMPORTANT NOTE:
WHEN STOP BUTTON IS NOT USED, ADD A JUMPER FROMTERMINAL 3 TO TERMINAL 5.
35
MAXIMUM RUN TIME:1 - ON: Maximum run time is 90 seconds.
OFF: Maximum run time is 45 seconds.
MAXIMUM RUN TIME:2 - ON: CLOSE limit switch B
OFF: CLOSE limit switch A
MAXIMUM RUN TIME:3 - OFF: (DO NOT ADJUST)
4 - OFF: (DO NOT ADJUST)CONSULT FACTORY FOR ADJUSTEMENT
SWITCH #1 SETTINGS
SWITCH #2 SETTINGS
TIMER TO CLOSE SWITCH SETTING:
O = ON F = OFF
1 2 3 4O O O OF O O O O F O O F F O O O O F O F O F O O F F O F F F O
1 2 3 4O O O F F O O F O F O F F F O F O O F F F O F F O F F F F F F F
Check at the intervals listed in the following chart.
EVERYEVERYEVERY
ITEMPROCEDURE3 MONTHS6 MONTHS12 MONTHS
Drive ChainCheck for excessive slack.
SprocketsCheck set screw tightness
FastenersCheck & tighten as required
Manual DisconnectCheck & Operate
Bearings & ShaftsCheck for wear & lubricate
Use SAE 30 Oil (Never use grease or silicone spray).
Repeat ALL procedures.
Do not lubricate motor. Motor bearings are rated for continuous operation.
Inspect and service whenever a malfunction is observed or suspected.
CAUTION: BEFORE SERVICING, ALWAYS DISCONNECT OPERATOR FROM POWER SUPPLY.
Check & adjust as required.
Lubricate.*
HOW TO ORDER REPAIR PARTS
OUR LARGE SERVICE ORGANIZATION
INSTALLATION AND SERVICE INFORMATION
ARE AVAILABLE 6 DAYS A WEEK
CALL OUR TOLL FREE NUMBER - 1-800-528-2806
HOURS 7:00 TO 3:30 p.m. (Mountain Std. Time)
MONDAY Through SATURDAY
SPANS AMERICA
WHEN ORDERING REPAIR PARTS
PLEASE SUPPLY THE FOLLOWING INFORMATION:
PART NUMBER DESCRIPTION MODEL NUMBER
ADDRESS ORDER TO:
THE CHAMBERLAIN GROUP, INC.
Electronic Parts & Service Dept.
2301 N. Forbes Blvd., Suite 104
Tucson, AZ 85745
10
Page 11
11
CONTROL WIRING
Standard C2 or B2 Wiring
Model MGJ operators are shipped from the factory
with jumper set for C2 wiring, which requires constant
pressure on button to close the door. If momentary
contact in close direction is desired (B2 wiring) you
must include an entrapment protection device. See
close control jumper setting below.
Constant pressure on close (C2 wiring)
Red jumper wire was placed on terminal #2 in
the electrical enclosure. The operator will require
constant pressure on close control in order to keep
door moving in the close direction.
Momentary contact on close (B2 wiring)
Move red jumper wire from terminal #2 to terminal
#3. The operator will require only momentary
contact to close the door.
LOCATING THE CONTROL STATION
All operators are supplied with some type of control station. Generally a three button station
(OPEN/CLOSE/STOP) is provided. A two-position key switch or control station (OPEN/CLOSE) may be added or
substituted when requested at the time of order. Mount the control station near the door.
WARNING
INSTALL THE CONTROL STATION WHERE THE
DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND
ITS HARDWARE. IF CONTROL STATION CANNOT BE
INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY
DEVICE OTHER THAN THE CONTROL STATION IS
USED TO ACTIVATE THE DOOR, A REVERSING
EDGE MUST
BE INSTALLED ON THE BOTTOM OF
THE DOOR. FAILURE TO INSTALL A REVERSING
EDGE UNDER THESE CIRCUMSTANCES MAY
RESULT IN SERIOUS INJURY OR DEATH TO
PERSONS TRAPPED BENEATH THE DOOR.
IMPORTANT: Mount WARNING NOTICE beside or
below the push button station.
MOUNT WARNING NOTICE
DETERMINE WIRING TYPE
Refer to the wiring diagram located on the inside cover the electrical box to determine the type of control wiring.
SPECIAL CONTROL WIRING
If your operator was shipped from the factory with
non-standard control wiring or with optional
accessories that require additional instructions, refer
to the wiring diagram(s) indicated in the special
control wiring data box. When a replacement wiring
diagram is present, wiring diagrams in this manual
will not apply. Refer only to the replacement wiring
diagram for all connections.
IMPORTANT NOTE: If your wiring diagram is
missing, or you are unsure of the wiring type for
your operator, contact the customer service
department @ 1-800-528-2806.
MODEL MGJ
Standard G2 Wiring
Model LGJ operators are supplied with type G2 control
wiring. Study the control features list below to
determine the features and type of control equipment
that may be used with your operator.
Entry Controls:
OPEN control requiring maintained contact.
OPEN control requiring only momentary contact.
CLOSE control requiring maintained contact.
CLOSE control requiring only momentary contact.
OPEN/CLOSE single control requiring momentary
contact..
STOP control requiring momentary contact.
Safety Devices:
External Interlock switch to disable all control
pneumatic safety (N.C.) to STOP while closing Safety
Device to REVERSE while closing Door Lock Sensing
Circuit.
Operational Features:
REVERSE (if closing) with momentary contact on
OPEN.
AUTOMATIC TIMER to CLOSE from any device.
AUTOMATIC TIMER to CLOSE from selected devices.
DELAY REVERSE in either direction for 1 second.
STOP after maximum run time is exceeded.
Note:
Refer to LGJ control connection diagrams on page 15.
MODEL LGJ
WARNING
Control Station
OPEN
Push
Buttons
CLOSE
STOP
WARNING
TO PREVENT ENTRAPMENT
DO NOT START DOOR DOWNWARD
UNLESS DOORWAY IS CLEAR
WARNING Notice
Page 12
(OPTIONAL)
SINGLE PHASE SCHEMATIC DIAGRAM for MGJ
1754
BK
(HOT) L2
BK
3
(OPTIONAL)
LIGHT
W
MAX.
100W
WIRE NUT
CLOSE-B
C
N.O.
W
BK
OPEN-A
CAPACITOR
R
STOP
MOVE JUMPER WIRE TO TERMINAL #2
FOR MOMENTARY CONTACT ON CLOSE
4
C
BL
BIMETAL
RELAY
RES.
Y
Y
B
A
Y
W
MOTOR *
Y
BK
O/L
R
PR1.
10VA.
24VAC.
SEC.
R
L1 (N)
BR
W
Y/BK
WIRE NUT
R3
BR
OPEN
SAFETY
EDGE
10
GY
PULL SWITCH
TO
OPEN & CLOSE
7
CLOSE
BR
R1
AUX.
CLOSE L/S
GY
Y
R2
Y
OR
GY
BL
OPEN-B
1
OR
AUX.
OPEN
L/S
P
2
12
OR
P
CLOSE-A
BL
C
OP
CL
N.O.
R
OPEN L.S.
OR
N.C.
CLOSE L/S
P
N.C.
11
W
C
W
W
C
* TO REVERSE MOTOR ROTATION INTERCHANGE
RED AND YELLOW MOTOR WIRES.
12
Page 13
13
THREE PHASE SCHEMATIC DIAGRAM for MGJ
1819
(YEL)
3 PHASE
POWER IN
3
STOP
OPEN
BRN
GY
PUR
YEL
BRN
1
2
3
7
85
9
230 VOLT - 3 PHASE
MOTOR CONNECTION
L3
L2
L1
(BK)
(BK)
(BK)
EXTERNAL
INTERLOCK
45
4
6
(BR)
BL/BK
O/L
BL/BK
*
230V BRAKE
(WHEN PRESENT)
(BRN)
(YEL)
14
(OR)
13
1
BRN
GY
PUR
YEL
BRN
1
2
3
460 VOLT - 3 PHASE
MOTOR CONNECTION
CL
OP
OP
CL
3
3
1
5
OVERLOAD
(IN MOTOR)
(OR)
A1
4
4
2
6
OP
7
4
85
9
6
OP
BL/BK
O/L
BL/BK
(OR)
A2
*
230V BRAKE
(WHEN PRESENT)
OP
CL
6
2
5
1
(BK)
PRI.
(BRN)
24VAC
SEC.
OPEN
LIMIT SWITCH
C
NC
(GY)
(PUR)
(YEL)
(BK)
(SEE NOTE #1)
T1
(YEL)
(OR)
WIRE
TO MOTOR
NUT
SAFETY EDGE
R1
(OR)
(OR)
OPEN & CLOSE
RADIO TO
(OR)
OPEN & CLOSE
R1
R2
CLOSE
(RED)
NOTE:
1. Voltage same as line voltage.
10
7
(YEL)
AUX. CLOSE
LIMIT SWITCH
(GY)
NC
(YEL)
(GY)
C
(OR)
NC
(RED)
R1
AUX. OPEN
LIMIT SWITCH
C
NO
(PUR)
2
(PUR)
14
13
(RED)
CLOSE CONTROL WIRING OPTIONS
C2 WIRING - Constant Presssure to Close
*
RED WIRE ON TERMINAL #2 (Shipped from Factory)
R1
(PUR)(PUR)(PUR)
CL
A2A1
CL
- Shipped from Factory
*
B2 WIRING - Momentary Contact to Close
MOVE RED WIRE FROM TERMINAL #2 TO TERMINAL #3
(RED)
CLOSE
LIMIT SWITCH
NC
R3
(RED)
(PUR)
C
Page 14
SINGLE PHASE SCHEMATIC DIAGRAM for LGJ
WARNING
1666
14
Page 15
15
LGJ CONTROL CONNECTION DIAGRAM
NUMBERED BOXES CORRESPOND WITH TERMINALS ON J1 CONNECTOR STRIP
If Neccessary, Remove The Connector Block From The Board To Secure Each Wire Connection
Connect field wires to any terminal number shown in the respective column. See control
options below for explanation of how field control will function for each terminal number.
OR
OR
OR
11
97
8435
OPEN
CLOSE
STOP
STANDARD
3 BUTTON CONTROL
105
SENSING
EDGE
85
9
11
ANY OPEN
CONTROL
(SEE NOTE)
65
ANY
OPEN & CLOSE
CONTROL
(SEE NOTE)
OR
OR
OR
11
97
8435
OPEN
CLOSE
STOP
OR
OR
OR
11
97
845
OPEN
CLOSE
STOP
OR
OR
OR
11
97
8435
OPEN
CLOSE
STOP
OR
OR
1145
OPEN
OFF
ON
CLOSE
2 BUTTON
CONTROL
(SEE NOTE)
3 BUTTON CONTROL
WITH
KEYED LOCK-OUT
3 BUTTON CONTROL
WITH
MULTIPLE CONTROL STATIONS
WHEN CONNECTING AN
OPEN CONTROL TO:
- Open control will require constant
pressure to keep door moving.
- Open control will only require
momentary contact and will set or
reset timer to close.
- Open control will only require
momentary contact and will NOT
set or reset timer to close.
WHEN CONNECTING AN
CLOSE CONTROL TO:
- Close control will require constant
pressure to keep door moving.
- Close control will only require
momentary contact.
DO NOT add unless using an
entrapment Protection device.
11
9
8
4
7
OPEN AND CLOSE CONTROL OPTIONS
IMPORTANT NOTE:
WHEN STOP BUTTON IS NOT USED, ADD A JUMPER FROM
TERMINAL 3 TO TERMINAL 5.
35
MAXIMUM RUN TIME: 1 - ON: Maximum run time is 90 seconds.
OFF: Maximum run time is 45 seconds.
MAXIMUM RUN TIME: 2 - ON: CLOSE limit switch B
OFF: CLOSE limit switch A
MAXIMUM RUN TIME: 3 - OFF: (DO NOT ADJUST)
4 - OFF: (DO NOT ADJUST)
CONSULT FACTORY FOR ADJUSTEMENT
SWITCH #1 SETTINGS
SWITCH #2 SETTINGS
TIMER TO CLOSE SWITCH SETTING:
O = ON F = OFF
1 2 3 4
O O O O
F O O O
O F O O
F F O O
O O F O
F O F O
O F F O
F F F O
1 2 3 4
O O O F
F O O F
O F O F
F F O F
O O F F
F O F F
O F F F
F F F F
Below are replacement kits available for your operator. Optional modifications and/or accessories included with
your operator may add or remove certain components from these lists. Please consult a parts and service
representative regarding availability of individual components of kits specified below. Refer to page 10 for all
repair part ordering information.
Electrical Box Cover
Electrical Box
Transformer, LGJ 115V-24VAC
Capacitor 220V 42MFD
Terminal Block 6 Pole
J2 Terminal Block, 16 Pole (1-16)
Hall Effect Assembly
PCB Board Assembly
PCB Board Standoff
Limit Shaft
3/8” Bearing, Plastic Flange
Limit Nut
Sprocket, 48B07
Rotor for RSL Assembly
Flat Washer, 3/8”
Roll Pin, 1/8” Dia. x 3/4” Long
E Ring, 3/8”
Depress Plate
Spring, Depress Plate
Limit Switch
Limit Switch
Standoff, #4-40 Threaded x .19 Long
Screw, #4-40 x 1” Pan Head Ph
Screw, #6-32 x 1” Pan Head Ph
Locknut #6-32
1
1
1
1
1
1
1
1
4
1
2
2
1
1
4
1
1
1
2
2
2
4
4
2
2
16
Page 17
WARNING
17
LGJ ELECTRICAL BOX - ILLUSTRATED PARTS
1
L3
L1
L5
L9
L3
7
L10
L7
L2
4
3
S2
S8
S3
S5
S4
S6
S1
2
5
9
8
S7
L2
L6
L4
6
L10
L10
L8
Page 18
REPLACEMENT PART LISTS – MODEL LGJ
WARNING
CAUTION
WARNING
WARNING
Refer to the parts lists below for replacement kits available for your operator. If optional modifications and/or
accessories are included with your operator, certain components may be added or removed from these lists.
Individual components of each kit may not be available. Please consult a parts and service representative
regarding availability of individual components. Refer to page 10 for all repair part ordering information.
K75-12583 DISCONNECT ASSEMBLY KIT
ITEM PART # DESCRIPTION QTY
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
10-11023
10-11393
10-11394
10-11399
11-11424
15-11379
18-11427
80-207-19
82-HX10-08T
85-FW-75
86-CP04-112
86-RP04-100
87-E-075
Bevel Gear Yoke
Disconnect
Release Lever
Retaining Plate
Disconnect Shaft
Sprocket, 48B14/41B14
Compression Spring
Key, 1/4 x 1-1/2” Long
Screw, #10-32 x 1/2” Hex
Flatwasher, 3/4”
Cotter Pin 1/8” x 1-3/4” Long
Roll Pin, 1/8” Dia. x 1” Long
E Ring 3/4”
1
1
1
1
1
1
1
1
5
1
1
1
1
INDIVIDUAL PARTS
ITEM PART # DESCRIPTION QTY
1
10-11397
2
10-11389-1
3
10-11398-2
4
32-11435
5
See Page 16
6
See Page 16
7
84-FN-10
8
84-FN-19144
Support Bracket
Mounting Bracket (LH)
Mounting Bracket (RH)
Gear Reducer, 40:1
Electrical Box
Motor
Nut
Stud
1
1
1
1
1
1
1
1
18
Page 19
19
LGJ ILLUSTRATED PARTS
D3
5
2
1
D5
D11
D12
D1
4
6
D10
D7
D2
D9
3
D8
D6
D13
D4
D9
7
8
Page 20
REPLACEMENT PART KITS MGJ
Below are replacement kits available for your operator. For replacement of electrical box, motor or brake
components be sure to match model number of your unit to kit number below to ensure proper voltage
requirements. Optional modifications and/or accessories included with your operator may add or remove certain
components from these lists. Please consult a parts and service representative regarding availability of individual
components of kits specified below. Refer to page 10 for all repair part ordering information.
Depress Plate
Spring, Depress Plate
SPDT Limit Switch
Spacer, .115” ID x 5/8” Long
Screw, #6-32 x 1” Pan HD PH
Screw, #4-40 x 1-1/2” Pan HD PH
Nut, #6-32 Double Tinnerman
Locknut #6-32
1) Reversing Contactor (03-11112), Used only on three
phase operators. Single phase operators use relays.
2) Capacitor (29-10338), Capacitor Clamp (10-11421)
and Resistor (29-2) used only on single phase
operators.
Qty
1
2
2
1
1
2
1
1
Qty
1
2
4
8
2
8
4
2
MGJ5043
MGJ5025
MGJ5038
20
Page 21
21
MGJ ELECTRICAL BOX - ILLUSTRATED PARTS
L8
L6
L2
1
L3
L1
L7
L2
4
7
3
9
S3
S9
S7
S4
S6
S3
S5
6
6
8
5
S2
S8
S1
2
S3
S7
S6
S4
S3
10
L3
L4
L5
Page 22
WARNING
CAUTION
WARNING
WARNING
WARNING
REPLACEMENT PART LISTS – MODEL MGJ
Refer to the parts lists below for replacement kits available for your operator. If optional modifications and/or
accessories are included with your operator, certain components may be added or removed from these lists.
Individual components of each kit may not be available. Please consult a parts and service representative
regarding availability of individual components. Refer to page 10 for all repair part ordering information.
K75-12567 DISCONNECT ASSEMBLY KIT
ITEM PART # DESCRIPTION QTY
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
D14
D15
07-11418
10-11023
10-11358
10-11394
11-11361
15-11377
18-10467
19-8A-12
80-11416
80-206-11
82-SH10-12
85-LS-10
86-CP04-112
86-RP04-100
87-E-100
Disconnect Hub
Bevel Gear Yoke
Disconnect Support Bracket
Release Lever
Disconnect Shaft MGJ
Sprocket, 41B19 x 1.25 Bore
Compression Spring
12ft. Of Sash Chain
Disconnect Key 1/4 x 1/4 x 7/8
Washer, 1” I.D. x 1/16” Thick
Screw, #10-32 Hex Head Socket
#10 Lock Washer ZP
Cotter Pin, 1/8” x 1-3/4” Long
Roll Pin, 1/8” Dia. x 1” Long
E Ring, 1” Plated
1
1
1
1
1
1
1
1
2
1
2
2
4
1
2
INDIVIDUAL PARTS
ITEM PART # DESCRIPTION QTY
1
10-11357
2
10-11359
3
32-11414
4
See Page 20
5
See Page 20
Brake Mounting Plate
Front Bracket
Gear Reducer, 45:1
Electrical Box
Motor
1
1
1
1
1
22
Page 23
23
ILLUSTRATED PARTS – MODEL MGJ
D8
D13
4
5
1
3
D10
D9
D7
D1
D15
D6
D15
D3
D4
D5
D13
D2
D12
D14
D11
2
Page 24
LISTED DOOR OPERATOR
41B6
MGJ CONTROL CONNECTION DIAGRAM
OPEN TIMER TO CLOSE
3 BUTTON STATION or 3 POSITION KEYSWITCH w/ SPRING RETURN TO CENTER AND STOP BUTTON
2 OR MOREKEY LOCKOUT
R1
R2
R3
1234
Stop
Close
Open
Stop
Close
Open
1234
Stop
Close
Open
2 BUTTON STATION or 3 POSITION KEYSWITCH w/ SPRING RETURN TO CENTER
STANDARD
124
Close
Open
ALL CONTROL WIRING TYPES
2 OR MORE
124
Close
Open
Close
Open
OPEN / CLOSE
3
7
RADIO CONTROL
1 BUTTON STATION or
ANY AUXILIARY DEVICE
RESIDENTIAL RADIO CONTROLS
SENSING DEVICE TO REVERSE OR STOP
EXTERNAL INTERLOCK
3
10
4
5
4
5
Remove Jumper
When Interlock is Used
ONE2 OR MORE
STANDARD
1234
Stop
Close
Open
IMPORTANT NOTES:
1) The 3-Button Control Station provided must be connected for operation.
2) If a STOP button is not used, a jumper must be placed between termianls 3 and 4.
3) Auxiliary control equipment may be any normally open two wire device such as
pullswitch, single button, loop detector, card key or such device.
Keyswitch
Sensing Device
ALL CONTROL WIRING TYPES
B2 or T1
WIRING TYPES ONLY
ALL CONTROL WIRING TYPES
T1 WIRING - RADIO TO OPEN ONLY
*
*
EXTERNAL
TERMINAL BLOCK
ALL CONTROL WIRING TYPESALL CONTROL WIRING TYPES
ALL CONTROL WIRING TYPES
TIMER TO CLOSE w/ WARNING LIGHT
ALL CONTROL WIRING TYPEST1 CONTROL WIRING ONLY
11
12
Timer Defeat
Switch
13
14
Power Supply for
Warning Light
Auxiliary Terminal Block
Warning Light will activate 15 sec. before door closes.
ALL CONTROL WIRING TYPES
ATTENTION ELECTRICIAN:
USE 16 GAUGE OR HEAVIER WIRE
FOR ALL CONTROL CIRCUIT WIRING.
SEE NOTE #2SEE NOTE #2SEE NOTES
#2 AND #3
(Refer to page 15 for model LGJ control connections)
01-11452H
c
2003, The Chamberlain Group, Inc.
All rights Reserved