LiftMaster KPR2000 User Manual

1
2
3
4
5
6
7
8
9
0
*
#

TABLE OF CONTENTS

WATERPROOF KEYPAD/PROXIMITY READER
MODEL KPR2000
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
CARTON INVENTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ONE YEAR LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
INSTALL THE KPR2000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CHOOSE AN OPERATION MODE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . .5
PROGRAM CARDS AND PINS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ADVANCED PROGRAMMING . . . . . . . . . . . . . . . . . . .7
PANIC CODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ALARM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
RESET THE KPR2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
ERASE ALL CODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1
INTRODUCTION
The LiftMaster KPR2000 is a single entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to perform in a wide range of indoor, outdoor, and harsh environments.
The KPR2000 supports up to 2000 users in multiple access configurations (Card Only, Card or PIN, or Card + PIN). The built in 125 KHz card reader supports HID 26 bit Wiegand and 30 bit Sentex Wiegand proximity card formats. The KPR2000 offers advanced programming features like; block enrollment, advanced relay programming, and Panic PINs/Cards (which open the entry and set off the alarm).
Features
• Waterproof (IP68) (meets or exceeds N4)
• Vandal Resistant Enclosure
• Backlit Keypad
• Multi-color LED status display
• Integrated Alarm Buzzer & Output
• One Programmable Relay Output
• Stand Alone or Pass-Through Operation
• 2000 Users (Card/PIN/Card+PIN)
• 10 Panic Card/PIN Codes
• Low power consumption (50mA)
• Anti-Tamper Alarm
• Latch Mode to hold door or gate open
Accessories
• Model PEDS44 Low Profile Access Pedestal
• Model PEDAD 4 x 4 Pedestal Adaptor
• Model PS12V2A 12 Vdc, 2 Amp Power Supply
Carton Inventory
NOT SHOWN: User's Manual
Diode IN4007 (For Relay
circuit protection)
Specifi cations
User Capacity . . . . . . . . . . .2000 Cards/PINS plus 10 Panic Cards/PINS
Operating Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 ~ 24 Vdc
Idle Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ~ 50mA
Active Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ~ 80mA
Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Key (3x4)
Proximity Card Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . HID 26 bit
and 30 bit (Sentex)
Radio Technology . . . . . . 125 KHz Industry Standard Proximity Card
Read Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 inch - 2.5 inches
Wiring Connections . . . . . . . . . . . . . .Relay Output, REX, DOTL, Alarm,
Wiegand (in/out)
Relay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . One (NO, NC, Common)
Adjustable Relay Output Time . . 1 ~ 99 Seconds (5 seconds default)
Adjustable Alarm Output Time . . . . . 0 ~ 3 Minutes (1 minute default)
Lock Output Load . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Amp Maximum
Alarm Output Load . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Amp Maximum
Wiegand Interface . . . HID Wiegand 26 and 30 bit Format Input & Output
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . Meets or exceeds IP68
Operating Temperature . . . . . . . . . . . .-20°C ~ 60°C, or -4°F ~ 140°F
Operating Humidity . . . . . . . . . . . . . . . 10% ~ 90% Non-Condensing
Physical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Zinc-Alloy Enclosure
Surface Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Powder Coat
Dimensions . . . . . . . . . . . . . . . . . . . L:128mm x W:82mm x D:28mm
Unit Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Pound
Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.4 Pounds
KPR2000
Keypad/Proximity Reader/Controller
Self Tapping Screws #8 x 1"
Wall Anchors #6 x 1 1/8"
Security Screwdriver
(T-10 Security Torx Driver)
Manager Add Card
Manager Delete Card
One Year Limited Warranty
The Chamberlain Group, Inc. warrants to the first consumer purchaser of this product that it is free from defect in materials and/or workmanship for a period of 1 year from the date of purchase.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
2

INSTALLATION

Install the KPR2000.
1
1
*
2
4
5
7
8
0
3
6
9
#
Choose an Operation Mode.
2
STAND ALONE OPERATION
The KPR2000 functions as a complete access control system. The user database is stored in non-volatile memory, reads the PINs and card codes, performs the authentication, and grants and monitors access to the property or device. In Stand Alone Operation there are three different Access Configurations listed below:
• Card or PIN (Default): The User must present a valid Wiegand Card to
the KPR2000 or enter their PIN code followed by the # key, in order to be granted access.
• Card Only: The User must present a valid Wiegand Card to the
KPR2000 in order to be granted access. The facility code and the ID number are both read and validated as one block of Wiegand data.
• Card + PIN: The User must first present a valid Wiegand Card to the
KPR2000 and then enter their PIN code followed by the # key, in order to be granted access.
PASS-THROUGH OPERATION
The KPR2000 passes all keypad and card reader Wiegand data to an external controller. The KPR2000 should be in the “Card or PIN” access configuration for pass-through operation.
IMPORTANT NOTE: Both modes of operation support Auto User ID generation (simplest method) and manual entry of user ID.
3

WIRING

Wire the KPR2000.
3
Wire Insulation Color Wiring Function Notes
Basic Stand Alone Wiring
Red Power + 12~24 Volts DC Regulated Power Input
Black Power - 12~24 Volts DC Regulated Power Input
Pink Power - Ground Conductor
Blue Relay NO Normally Open Relay Output (Install diode provided)
Purple Relay Common Common Connection for Relay Output
Orange Relay NC Normally Closed Relay Output (Install diode provided)
Pass-Through Wiring (Wiegand Master and Remote)
Green Data 0 Wiegand Output (Pass-through)/Input (Stand Alone) Data 0
White Data 1 Wiegand Output (Pass-through)/Input (Stand Alone) Data 1
Pink Ground
Advanced Input and Output Features
Yellow REX Request To Exit (REX) Input
Gray Alarm Output Negative contact for Alarm
Brown Contact Input Door/Gate Contact Input (Normally Closed)
WIRING EXAMPLES:
Gate/Door Operator or Fail-Secure Strike
Install a 1N4007 or
Normally Open
Common
(1 Amp Maximum)
Networking Two KPR2000 Units or Connecting to an Access Control System
Normally Open
External Alarm
(1 Amp Maximum)
equivalent diode.
Blue
Purple
Red
Gray
Pink
Black
Common
Black
KPR2000
Blue
Purple
Red
Gray
Pink
Install a 1N4007 or equivalent diode.
KPR2000 Stand-Alone
(Master Unit)
Magnetic Lock or Fail-Safe Strike
Normally Closed
External AlarmExternal Alarm
(1 Amp Maximum)
KPR2000 Stand-Alone
(Remote Unit)
Red
Black
Pink
Common
Install a 1N4007 or equivalent diode.
KPR2000
Orange Purple
Red Gray
Pink
Black
Green (Data 0)
White (Data 1)
Pink (must connect for ground reference)
Maximum of 500 feet (152.4 m)
4

PROGRAMMING

Confi gure the KPR2000.
4
Change the configure settings according to your application (optional). Multiple configuration settings can be changed at one time: enter program mode, change desired settings, then exit program mode.
SET MASTER CODE
The 6 digit Master Code is used to prevent unauthorized access to the system. To interface with the KPR2000, the manager will need a Master Code (factory default code: 888888). We highly recommend immediate update and recording of your Master Code.
Programming Step Keystroke Combination
1. Enter Program Mode
2. Update Master Code 0 (New Code) # (New Code) #
3. Exit Program Mode
(Master Code) #
SET ACCESS CONFIGURATION
There are 3 types of access configurations for the KPR2000:
• Card or PIN (Default): The User must present a valid Wiegand Card to
the KPR2000 or enter their PIN code followed by the # key, in order to be granted access.
• Card Only: The User must present a valid Wiegand Card to the
KPR2000 in order to be granted access. The facility code and the ID number are both read and validated as one block of Wiegand data.
• Card + PIN: The User must first present a valid Wiegand Card to the
KPR2000 and then enter their PIN code followed by the # key, in order to be granted access.
Programming Step Keystroke Combination
1. Enter Program Mode
2. Card Only
OR
2. Card + PIN
OR
2. Card or PIN
3. Exit Program Mode
(Master Code) #
3 0 #
3 1 #
3 2 #
SET RELAY CONFIGURATION
The relay configuration sets the behavior of the output relay on activation.
Programming Step Keystroke Combination
1. Enter Program Mode
2. Pulse Mode
OR
2. Latch Mode
3. Exit Program Mode
(Master Code) #
4 (1-99) # The relay time is 1-99 seconds
(default is 5 seconds) 4 0 # Sets the relay to ON/OFF latch mode
SET WIEGAND INPUT/OUTPUT OPTIONS
The KPR2000 offers input and output for industry standard Wiegand devices (refer to Specifications). Default is HID 26 bit.
SET DOOR OPEN TOO LONG (DOTL) ALARM
This setting requires an external sensor input. The alarm output timing can be set from 1-3 minutes (default is 1 minute). Factory default is OFF.
Programming Step Keystroke Combination
1. Enter Program Mode
2. DOTL Alarm OFF
OR
2. DOTL Alarm ON
OR
2. DOTL Output Timing
3. Exit Program Mode
(Master Code) #
6 0 #
6 1 # (Alarm sounds for 1 minute)
9 (1-3) #
SET STRIKE-OUT ALARM
The strike-out alarm will engage after 10 failed card/PIN attempts. Factory default is OFF. The strike-out alarm can be set to deny access for 10 minutes after engaging or it can be set to disengage only after entering a valid master code or card.
Programming Step Keystroke Combination
1. Enter Program Mode
2. Strike-Out OFF
OR
2. Strike-Out ON
OR
2. Strike-Out ON
3. Exit Program Mode
(Master Code) #
7 0 # (Factory default)
7 1 # Access will be denied for 10 minutes
7 2 # Enter Master Code or Valid Card to
silence
SET AUDIBLE AND VISUAL RESPONSE
Factory default is ON.
Programming Step Keystroke Combination
1. Enter Program Mode
2. Control Backlight
OR
2. Control LED
OR
2. Control Sounds
3. Exit Program Mode
(Master Code) #
ON = 7 5 #
ON = 7 7 #
ON = 7 9 #
OFF = 7 4 #
OFF = 7 6 #
OFF = 7 8 #
Programming Step Keystroke Combination
1. Enter Program Mode
2. Set Wiegand Format 9 (Bit Format) # Bit Format = Valid 2 digit
3. Exit Program Mode
(Master Code) #
format (example: 26 or 30)
5
PROGRAMMING
Program Cards and PINS.
5
Programming will vary depending on the access configuration. Follow the instructions according to your access configuration.
GENERAL PROGRAMMING INFORMATION
User ID Number: Assign a user ID number to the access code in order to keep track of the users of access cards or PINs. The user ID number can be any number from 1~2000. IMPORTANT: User IDs do not have to be proceeded with any leading zeros. Recording of User ID
is critical. Modifications to user data require either the card or the User ID be available.
Proximity Card: Any 125 KHz industry standard 26 bit Wiegand Proximity Card.
Keypad PIN: The PIN can be any 4~8 digits between 0000~99999999 (except 1234 which is reserved for factory testing). IMPORTANT: PINs less than 1000 must be preceded with leading zeros. PINs greater than 9999 do not require any leading zeros.
ACCESS CONFIGURATION: CARD OR PIN & CARD ONLY
ADD USER CARD(S)
Programming Step Keystroke Combination
1. Enter Program Mode
2. Add Card: Using Auto ID
(Allows KPR2000 to assign Card to next available User ID number)
OR
2. Add Card: Select Specific ID
(Allows manager to define a specific User ID to associate the card to)
OR
2. Add Card: Block Learn (Allows manager to add up to
2000 cards to the KPR2000 in a single step †). Takes 2 minutes to program.
3. Exit Program Mode
(Master Code) #
1 (Read Card) #
Repeat Step 2 for additional user cards
1 (User ID) # (Read Card) #
5 (User ID) # (The first card number) # (Card Quantity) #
Card quantity = number of cards to be enrolled
DELETE USER CARD(S)
Programming Step Keystroke Combination
1. Enter Program Mode
2. Delete Card - By User ID
OR
2. Delete Card - By Card
OR
2. Delete Card -By Card Number
3. Exit Program Mode
(Master Code) #
2 (User ID) #
Deleting by User ID number will clear cards and PINs
2 (Read Card) #
Requires the user card. Deletes ONLY the card number
2 (Card Number) #
Deletes ONLY the card number †
ADD OR DELETE A PIN
Programming Step Keystroke Combination
1. Enter Program Mode
2. Add a PIN
Assigns PIN to user ID number
OR
2. Delete a PIN
Deletes the User ID number and associated PIN
3. Exit Program Mode
(Master Code) #
1 (User ID) # (PIN) #
Repeat Step 2 for additional PINs
2 (User ID) #
Repeat Step 2 for additional PINs
CHANGE A PIN
This operation is executed from outside of Program Mode.
Programming Step Keystroke Combination
1. Change a PIN
(User ID) (Old PIN #) (New PIN #) (New PIN #)
† BLOCK LEARN DIRECT ENTRY
Format for programming specific Card Numbers: Facility Code + ID Number (including leading 0’s) Example: FAC- 24, ID- 100 would be entered as:
26 Bit: 02400100 30 Bit: 002400100
6
PROGRAMMING
ACCESS CONFIGURATION: CARD ONLY
USING MANAGER CARDS
KPR2000 managers can use manager cards to program user cards into and out of the system. There are two pre-programmed manager cards (an Add Card, and a Delete Card) to allow rapid card enrollment. This is a form of Auto User ID enrollment and is only available in “Card Only” configuration.
ACCESS CONFIGURATION: CARD + PIN
ADD A CARD + PIN USER
Programming Step Keystroke Combination
1. Enter Program Mode
2. Add a User Card
Assigns card number to User ID
3. Exit Program Mode
4. Add PIN (Read Card) (1234#) (New PIN #) (New
(Master Code) #
1 (Read Card) # OR 1 (User ID) # (Read Card) #
PIN #)
This operation is executed from outside of Program Mode
Programming Step Keystroke Combination
Add a User Card 1. (Read Manager Add Card)
2. (Read User Card)
Repeat Step 2 for additional user cards
3. (Read Manager Add Card)
Delete a User Card 1. (Read Manager Delete Card)
2. (Read User Card)
Repeat Step 2 for additional user cards
3. (Read Manager Delete Card)
CHANGE PIN
Allows card user to update the PIN for their card + PIN User ID. This operation is executed from outside of Program Mode.
Programming Step Keystroke Combination
1. Change PIN using a Card
OR
1. Change PIN using PIN
(Read Card) (Old PIN #) (New PIN #) (New PIN #)
(User ID) (Old PIN #) (New PIN #) (New PIN #)
DELETE CARD BY USER ID
Deleting by ID number will clear cards and PINs.
Programming Step Keystroke Combination
1. Enter Program Mode
2. Delete User Card by User ID
3. Exit Program Mode
(Master Code) #
2 (User ID) #

ADVANCED PROGRAMMING

Panic Codes
There is a section of the KPR2000 memory set aside specifically for cards and PINs to be used in the instance of an emergency. There are several rules that guide the use of these cards/PINs:
Panic Codes activate the relay and the alarm/alarm output.
Panic Codes use a User ID of 2001~2010 ONLY.
Panic Codes must be unique. Duplicated Codes act as a normal User Code.
ADD OR DELETE A PANIC PIN ADD OR DELETE A PANIC CARD
Programming Step Keystroke Combination
Panic PIN Codes: Add or Delete a PIN
1. Enter Program Mode
2. Add a PIN
OR
2. Delete a PIN
3. Exit Program Mode
(Master Code) #
8 (User ID Number) # (PIN) #
2 (User ID Number) #
Programming Step Keystroke Combination
1. Enter Program Mode (Master Code) #
2. Add a User Card
OR
2. Delete a User Card
3. Exit Program Mode
8 (User ID Number) # (Card) #
2 (User ID Number) #
7
ADVANCED PROGRAMMING
Alarm
TO RESET THE ALARM
Programming Step Keystroke Combination
To reset the door forced open warning
To reset the door open too long (DOTL) warning
(Read valid card) OR (Master Code #)
(Read valid card) OR
(Master Code) #
ANTI-TAMPER ALARM
The KPR2000 uses an optical sensor as the input for its internal alarm. If the case is opened while the KPR2000 is powered, the alarm will operate. To silence, enter a valid credential or cycle power.
Sound & Light Indication
Reset the KPR2000
This will reset the KPR2000 to the factory default but all card/PIN information will still be retained. This will also require reprogramming of the Master Add and Delete Cards. NOTE: This is useful if the original
Master Add and Delete Cards have been lost.
1. Power the KPR2000 down.
2. Press and hold the button while power is restored to the KPR2000.
3. Release the button and wait until the amber LED shines.
4. Present any 26 bit proximity card or the Manager Add Card (provided) to the KPR2000. This card is now the Manager Add Card.
5. Present any 26 bit proximity card or the Manager Delete Card (provided) to the KPR2000. This card is now the Manager Delete Card.
When the red LED begins to blink, the KPR2000 has been successfully reset.
Erase all Codes
This will delete ALL User data.
1. Enter Program Mode by pressing: (Master Code) #.
2. Press 2 0000 #.
All configuration data is retained.
Operation Status Red LED Green LED Amber LED Sounds
Power On Flashing Short Single Beep
Standby Flashing
Press Keypad Flashing Short Single Beep
5 Second Time-out Flashing 3 Short Beeps
Enter Master Code Entry Mode ON
In Program Mode ON Single Flash Short Single Beep
Entered Single Program Step Successfully ON Single Flash Short Single Beep
Entered Continuous Program Step Successfully Single Flash ON Short Single Beep
Entered Program Step Incorrectly ON 3 Short Beeps
Exited from Program Mode Flashing Short Single Beep
Entry Granted ON Short Single Beep
Alarm Mode Engaged Flashing Alarm
Pressing Toggles Standby/Master Code Entry ON/Flashing Short Single Beep
Short Single Beep
FOR TECHNICAL SUPPORT DIAL OUR TOLL FREE NUMBER:
1-800-528-2806
© 2012, The Chamberlain Group Inc. 01-36716B All Rights Reserved