Lift-Master K90-9210M1 User Manual

To prevent possible SERIOUS INJURY or DEATH from electrocution, disconnect electric power to operator BEFORE installing.
ALL electrical connections MUST be made by a qualified individual.
WARNING
APPLICATION
This wiring modification is available to models T, GT, APT, J, H, GH, SD and GSD standard door operators with 24V control circuits (M) and logic control board (L).
NOTE: Not available with Hazardous Area or Variable Speed Modifications.
FUNCTIONS
Each switch, or pole, provides a means to control auxiliary lights, heaters or other equipment. The switch can be used to turn on or off such equipment when the door is fully opened or fully closed.
COMPONENT MOUNTING
1. Locate the new auxiliary limit switch bracket assembly with the limit switches attached.
2. Fasten the limit switch bracket down to the box using the two #8-32 x 1/4" long self tapping screws provided (Figure 3).
3. If the bracket interferes with the screws from the open and close limit switch, install the backup plates provided, between the electrical box and the head of the screw (Models T, GT and GH only).
4. Connect ends of wire leads to desired field wiring with wire nuts to complete installation (Figures 1 and 2).
NOTE: Auxiliary limit bracket assemblies with one switch are shipped set up for auxiliary closed. If auxiliary open is required, remove auxiliary switch and flip over.
CARTON INVENTORY
K90-9210M1 K90-9210M2
DESCRIPTION QTY QTY
Limit switch 1 2 Pan head screw
#4-40 x 3/4" 2 4 Internal tooth lockwasher 2 4 Limit switch backup plate 1 2 Limit switch nut plate 1 2 Limit switch mounting
bracket “H” 1 1 Limit switch mounting
bracket “T” 1 1 Pan Head screw
#8-32 x 1/4" 3 3 White wire used with “OPEN”
limit switch 16 Gauge, 24" 3 3 Blue wire used with “CLOSE”
limit switch 16 Gauge, 24" 3 3
AUXILIARY LIMIT SWITCH
Mini Switches and Wire Leads
© 2005, The Chamberlain Group, Inc.
01-13162C All Rights Reserved Printed in Mexico
FIGURE 1
FIGURE 2
FIGURE 3
AUXILIARY OPEN or CLOSE LIMIT SWITCH
AUXILIARY OPEN LIMIT SWITCH
AUXILIARY CLOSE LIMIT SWITCH
Pan Head Phillips #4-40x3/4"(2)
Long Pan Head Phillips #8-32x1/4"(2) (2 per bracket)
Nut Plate
Auxiliary Switch Mounting Bracket
Pan Head Phillips #8-32x1/4" (3)
NC
NO
NC
NO
NC
NO
MODELS T, GT, GH
#4 Internal Tooth Lockwasher
Backup Plate (1 per switch)
Limit Switch
Auxiliary Switch Mounting Bracket
*NOTE: Auxiliary switch components used with ”T” electrical boxes are the same as “H” electrical boxes unless otherwise noted.
MODELS H AND J
WH
WH
WH
C
C
*Refer to NOTE
WH
WH
WH
BL
BL
BL
(C)
(NO)
(NC)
(C)
(NO)
(NC)
(C)
(NO)
(NC)
INSTALLATION INSTRUCTIONS
WARNING
COMPONENT MOUNTING:
1. Locate the new auxiliary limit switch bracket assembly with the limit switch attached and terminal block (when present).
2. Fasten the limit switch bracket down to the box using the two #8-32 x 1/2” long self tapping screws supplied (refer to component mounting illustration).
WARNING
TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER TO OPERATOR BEFORE INSTALLING.
3. When Present fasten the terminal block down to the box using the two #8-32 x 5/8” long self tapping screws supplied (refer component mounting illustration).
4. If the Bracket interferes with the screws from the open and close limit switch, install the backup plates supplied, between the electrical box and the head of the csrew (Model T, GT, GH only). Refer to illustration below.
Wiring For Modification With Wire Leads:
1. Connect ends of wire leads to desired field wiring with wire nuts to complete installation (Refer to figure 2 and 3).
Wiring For Modification With Terminal Leads:
1. Connect the wires from the auxiliary limit switch to the new terminal block (Refer to figure 2 and 3).
FIGURE 1: Open or Closed Auxiliary Switch NOTE: Auxiliary limit bracket assemblies with one
switch are shipped set up for auxiliary closed. If auxiliary open is required remove auxiliary switch and flip over.
FIGURE 2: Open or Closed Auxiliary Switch
AUXILIARY OPEN/ CLOSE LIMIT SWITCH
TERMINAL BLOCK, 6 POLE (WHEN PRESENT)
NC NO
C
WH
WH
WH
20
21
22
(C)
(NO)
(NC)
FIGURE 3: Open and Closed Auxiliary Switch
AUXILIARY OPEN LIMIT SWITCH
AUXILIARY CLOSE LIMIT SWITCH
TERMINAL BLOCK, 6 POLE (WHEN PRESENT)
NC NO
NC NO
C
WH
WH
WH
C
BL
BL
BL
20
21
22
23
24
25
(C)
(NO)
(NC)
(C)
(NO)
(NC)
COMPONENT MOUNTING
(2) 1/4” LONG PAN
HEAD PHILLIPS
(2) #8-32x5/8” PAN
HEAD PHILLIPS
(2 PLACES)
#8-32 LOCK NUT
MODELS T,GT,GH
(LOW PROFILE BOX)
01-13162B All Rights Reserved
(2 PLACES)
AUXILIARY LIMIT SWITCH
BRACKET ASSEMBLY
10-12806 BACKUP PLATE
TERMINAL BLOCK, 3 OR 6
POLE (WHEN PRESENT)
© 1999, The Chamberlain Group, Inc.
(2) #8-32x5/8” PAN
HEAD PHILLIPS
(2 PLACES)
(2) 1/4” LONG PAN
HEAD PHILLIPS
(3 PLACES)
MODELS H & J
(CUBE BOX)