To prevent possible SERIOUS INJURY or DEATH from electrocution:
• Be sure power is not connected BEFORE installing the receiver.
To prevent possible SERIOUS INJURY or DEATH from a moving gate
or garage door:
• ALWAYS keep remote controls out of reach of children. NEVER
permit children to operate, or play with remote control transmitters.
• Activate gate or door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keep gate or garage door in sight until completely closed.
NEVER permit anyone to cross path of moving gate or door.
WARNING
Universal Radio Control
OWNERS MANUAL
Model 535-315LM SECURITY✚ Receiver Only
Mounting Receiver
• Unplug the opener before proceeding.
• Fully extend antenna wire below bottom of case as shown.
• The receiver can be mounted directly on the door opener with
the clips provided. Figure 1.
or
• Attached to a ceiling/inside wall of the garage with connecting
bell wire (not provided). Fasten the receiver to the ceiling or
inside garage wall with dry wall screws provided. Figure 2.
NOTE: Transformer Model 85 is required if your residential
garage door opener is a LiftMaster, Chamberlain or Sears.
Installation Using Clips
Loosen the three terminal screws on the receiver (labeled 1, 2
and 3) Figure 1. Insert one end of a mounting clip under each
terminal. Do not retighten at this time.
Loosen the three terminal screws on the opener used for push
button controls and radio power.
Leaving the push button bell wire in place, insert the other ends
of the mounting clips under the opener terminal screws.
NOTE: If the number sequence of opener terminals doesn't
match the receiver, turn the receiver around (so back is facing
out) and complete the connection.
Retighten the terminal screws on opener and receiver.
Reconnect power to the opener. The receiver push bar should
light. If it does not, use Transformer Model 85.
Installation Using Bell Wire
Attach one end of 3-strand bell wire (not provided) to receiver
terminals 1, 2 and 3. Connect the other end to the three opener
terminals used for push button controls and radio power. Use
insulated staples to secure bell wire between receiver and
opener. Figure 2.
Reconnect power to the opener. The receiver push bar should
light. If it does not, use Transformer Model 85.
Installation With Transformer Model 85
With the transformer, use a 2-wire connection only. Attach wire
to receiver terminals 1 and 2 and to the opener terminals used
for push button control. Plug the transformer into receiver and
120 Volt outlet. Figure 3.
Antenna Wire Fully Extended
®
Radio Power
Push Button
Common
Opener
Terminals
Antenna Wire
Fully Extended
Radio Power
Push Button
Common
3
21
Opener
Terminals
®
Opener Terminals
Push Button
3
2
1
3
2
1
®
© 2006 The Chamberlain Group, Inc.
114A2578D All Rights Reserved
Programming the Remote to the Receiver
With SECURITY✚, the code between the remote control and the
receiver changes with each use, accessing over 100 billion new
codes.
You can activate your opener with up to 8 SECURITY✚ remote
controls, and one SECURITY✚ Keyless Entry.
1. Pry open the front panel of receiver case with a coin or a
screwdriver. Re-connect power to opener.
2. Press and release the “learn” button on the receiver. The learn
indicator light will glow steadily for 30 seconds.
3. Within 30 seconds, press and hold the button on the handheld remote that you wish to operate your garage door.
The opener will now operate when the push button on either the
receiver or the remote control transmitter is pressed.
Repeat Steps 2 and 3 for each remote control that will be used
to operate the garage door opener.
To Erase all Remote Control Codes
Press and hold the “learn” button on the receiver panel until the
indicator light turns off (about 6 seconds). All transmitter codes
are now erased. Then follow the steps above to reprogram each
remote control.
Set Output Duration
(Commercial APPLICATIONS Only)
For commercial applications, the receiver can be set for either
constant or momentary closure on the output contacts. Use of
constant closure is prohibited on residential garage door openers
because it overrides the safety reversal devices.
With the jumper in the “M” (Momentary) position, the contacts
will close for 1/4 second regardless of the length of radio
transmission. With the jumper in “C” (Constant) position, the
contacts will stay closed as long as the radio continues
transmitting.
The receiver is factory set at M.
To prevent possible SERIOUS INJURY or DEATH, the use of
CONSTANT OPERATION on residential openers is PROHIBITED.
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this
receiver and/or transmitter are prohibited, except for changing the code setting or replacing the
battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
SPECIFICATIONS
Output Rating......................................5 Amps 28VAC or DC Max.
Power ....................................................18V - 30V ~, 30mA, 60Hz
18 - 30V , 30mA
RF Frequency....................................................................315MHz
If the power is other than shown in specifications, Accessory
Transformer Model 85 or 95 is required.
Accessory Transmitters — Series 50, 60, 70, 80 and 900.
Indicator
Light
Learn
Button
Option
Jumper
1
2
3
¤
C
P2
M
C
P2
M
WARNING
CONSTANT
OPERATION
Output
Duration
Terminals
Jumper
M
MOMENTARY
OPERATION
Output
Duration
Terminals
Jumper
M