FUNCTION
The Herkules Motion Detector is a microwave sensor sending out a high frequency sound wave while listening for bounce back. When the sound wave is returned at a different frequency the sensor knows that there is a moving object within the detection zone. A signal is sent to the internal relay, which is wired to the door control’s activation input.
FACTORY DEFAULT SETTINGS
Mounting Height . . . . . . . . . . . . . .13' to 16' above the
ground
Relay Hold Interval 1 . . . . . . . . . .2 seconds output
Slow Motion Detection . . . . . . . . .Medium detection
(detects very slow objects) Separation People and Vehicles . .ON
Cross Traffic Detection . . . . . . . . .Medium
Direction Recognition . . . . . . . . . .Forward (movement toward
the detector)
NOTE: If other settings are desired, then they can be changed by using the optional remote control or with the internal push buttons in the detector.
ADDRESSING THE SENSOR
This assists in programming and reduces interference if multiple units are used on the same location.
1. Open cover to motion detector.
2. Find Dip switches.
3. Adjust Dip switches.
HERKULES MOTION
DETECTOR
50HERK
PROGRAMMING
PROGRAMMING MOUNTING HEIGHTS (Only use if factory default is not desired)
Without push-button remote:
1. Open detectors face plate.
2. Press both buttons "X" and "Y" for 2 seconds, the green LED will flash (you are now in programming mode).
3. Press "X" button 2 times.
4. Press "Y" button for the desired height:
2 times for 8' to 9.5' 3 times for 9.5' to 12.5' 4 times for 12.5' to 16' 5 times for 16' to 19' 6 times for 19' to 22.5' 7 times for 22.5' to 23'
With (optional) remote:
1. Point the remote at the motion detector.
2. Press "G" the Start key.
3. Press "F" and then press the following number to set the height:
#2 once for 8' to 9.5' #3 once for 9.5' to 12.5' #4 once for 12.5' to 16' #5 once for 16' to 19' #6 once for 19' to 22.5' #7 once for 22.5' to 23'
4. When you press the number for the desired height, the lighted button will stay on indicating the programming is complete. If the button flashes, then the sensor did not accept the program.
QuickStart
Address Switch 1 Switch 2
Address 1 Off Off
Address 2 On Off
Address 3 Off On
Address 4 On On
1 2
O
Address 1
N
Y
X
Programming Buttons
Address Dip Switch
1 2
O
Address 2
Address 3
Address 4
N
1 2
O N
1 2
O N
© 2005, The Chamberlain Group, Inc.
01-32999 All Rights Reserved Printed in Mexico
MECHANICAL OPERATOR
LOGIC OPERATOR
LOGIC 3 TERMINAL STRIP
LOGIC 2 TERMINAL STRIP
Herkules Microwave Sensor
Herkules Microwave Sensor
White 24 VAC AC/DC
Brown 24 VAC AC/DC
White
Brown
Red
Pink
14 24 VAC AC/DC
13 24 VAC AC/DC
12
11
10
9
8
7 Open
6
5
4 Com
3
2
1
Pink
Red
1 2 3 4 5 6 7 10 L1 L2 L3
Open
Com
White
Brown
OR
Red
Pink
13 24 VAC AC/DC
12 24 VAC AC/DC
11
10
9
8
7 Open
6
5
4 Com
3
2
1
Loading...