LifeSource UA-853 User Manual

Premium Automatic
Blood Pressure Monitor
Trilingual Instruction Guide - Model UA-853
English l Français l Español
IMPORTANT INFORMATION
Please read this important information before using your monitor.
Please remember that only a medical practitioner is qualified to interpret
your blood pressure measurements. Use of this device should not replace regular medical examinations.
Consult your physician if you have any doubt about your readings.
Should a mechanical problem occur, contact LifeSource® at 1-888-726-9966.
Do not attempt to service, calibrate, or repair this monitor.
Because your UA-853 monitor contains delicate, high-precision parts,
avoid exposing it to extremes in temperature or humidity or to direct sunlight, shock and dust. LifeSource® guarantees the accuracy of this monitor only when it is stored and used within the temperature and humidity ranges noted on page E-21.
Clean the monitor and cuff with a dry, soft cloth or a cloth dampened
with water and a mild detergent. Never use alcohol, benzene, thinner or other harsh chemicals to clean monitor or cuff.
Remove and replace batteries if monitor is not used for more than six
months. Alkaline batteries recommended.
PRECAUTIONS
The UA-853 is designed to be used at home, by those who are eighteen (18) years and older, to monitor blood pressure (systolic and diastolic) and pulse rate.
Fast. Easy. Accurate.
Congratulations on purchasing a state-of-the-art LifeSource® blood pressure monitor—one of the most technologically advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen.
Physicians agree that daily self-monitoring of blood pressure is an important step individuals can take to maintain cardiovascular health and prevent the serious consequences associated with undetected and untreated hypertension.
A&D Medical has been manufacturing high quality healthcare products for ove 20 years. We are committed to providing you and your family with monitoring devices that provide the utmost in accuracy and convenience.
LifeSource - Designed for Life.
?
TABLE OF CONTENTS
WHAT DISPLAY SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-2
MONITOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-3
HOW UA-853 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-4
BEFORE YOU START . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4
SELECTING THE CORRECT CUFF SIZE . . . . . . . . . . . . . . . . . . . . . . . . . .E-5
TAKING YOUR BLOOD PRESSURE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-6
WHAT IS AN IRREGULAR HEARTBEAT . . . . . . . . . . . . . . . . . . . . . . . . . E-11
ABOUT CUFF INFLATION METER . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-11
ABOUT AVERAGE READING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-12
ABOUT PRESSURE RATING INDICATOR™ . . . . . . . . . . . . . . . . . . . . . . . E-12
ABOUT MEMORY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-13
USING THE MONITOR WITH AC ADAPTER . . . . . . . . . . . . . . . . . . . . . . E-14
ABOUT BLOOD PRESSURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-15
TROUBLESHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-20
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-21
CONTACT INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-22
FRENCH INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-1
SPANISH INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S-1
In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991
E-1
?
p-3
1932-1AIc UA787EXC¥06 illust¥03,12p
1932-1AIc UA787EXC¥06 illust¥03,12p
1932-1AIc UA787EXC¥06 illust¥03,12p
1932-1AIc UA787EXC¥06 illust¥03,12p
1932-1AIc UA787EXC¥06 illust¥03,12p
1932-1AIc UA787EXC¥06 illust¥03,12p
WHAT DISPLAY SYMBOLS MEAN
Display/
Symbol
Battery Full
Battery Low
PULSE DISPLAY ERROR
Condition/Cause
The symbol shown while measure­ment is in progress. It blinks while detecting the pulse.
An irregular heartbeat or body movement may have occurred. Refer to page E-11 for more infor­mation on irregular heartbeats.
Previous measurement stored in MEMORY.
The battery power indicator during measurement.
The batteries are low when it blinks.
Unstable blood pressure due to excessive body movement.
The systolic and diastolic values are within 10 mmHg of each other.
The pressure value did not increase during inflation.
The cuff is not fastened correctly.
There is an air leak in the cuff or monitor.
The pulse is not detected correctly.
Cuff Inflation Meter
Pressure Rating Indicator™
The alarm is turned on.
Recommended
Action
Measurement is in progress, remain as still as possible.
Take measurement again and consult with your physician.
Replace all batteries with new ones when the symbol blinks. Alkaline batteries recommended.
Try the measurement again. Remain very still during the measurement.
Fasten the cuff correctly, and try the measurement again.
Check for air leaks along the tube and around the air socket.
Refasten the cuff and retake mea­surement.
Make sure tube is properly con­nected to cuff and monitor.
Try the measurement again. Remain very still during the measurement.
Measurement is in progress, remain as still as possible.
Refer to the section “About Pressure Rating Indicator” for further explanation.
Press AM button once to turn alarm off.
E-2
?
LifeSource Health Line (Toll-Free): 1-888-726-9966
MONITOR COMPONENTS
Arm Cuff
Air Hose
BACK
Air Connector Plug
AM Button
PM Button
Air Socket
Battery Compartment
Display
MEMORY Button
FRONT
START Button
(Orange illumination during the AM) (Blue illumination during the PM)
Battery Cover
AC Adapter Jack
In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991
AC Adapter
E-3
HOW UA-853 WORKS
?
LifeSource® blood pressure monitors are easy to use, accurate and digitally display full measurement readouts. Our technology is based on the “oscillometric method” – a noninvasive blood pressure determination. The term “oscillation” refers to any measure of vibrations caused by the arterial pulse. Our monitor examines the pulsatile pressure generated by the arterial wall as it expands and contracts against the cuff with each heartbeat.
The cuff is inflated until the artery is fully blocked. The inflation speed is maximized and the pressure level is optimized by the device. The monitor takes measurements while the cuff is both inflating and deflating. This results in a faster measurement providing greater comfort to the user.
AM/PM TimeWise™ Technology
This monitor automatically stores each measurement as an AM or PM reading in memory (note: clock must be properly programmed before initial use). Healthcare providers agree that understanding your AM and PM readings can assist in the proper diagnosis and management of your heart health through lifestyle and/or medication modifications.
BEFORE YOU START
You must install 4 type AA (1.5 volt) batteries (alkaline batteries recommended), or use the AC Adapter (see page E-14 for using the Monitor with AC Adapter) and attach the cuff to the monitor before using it. To install batteries (or replace them if the “Low Battery” symbol appears on display), proceed as follows:
1. Remove battery compartment cover by gently pushing down on arrow and sliding cover forward.
2. Put in bottom row of batteries first. Place the batteries in compartment with positive (+) and negative (–) terminals matching those indicated in the compartment. Be sure batteries make contact with compartment terminals.
3. Replace cover by sliding it into the compartment and gently pressing into place.
NOTE: Rechargeable batteries will not work with this monitor.
E-4
?!
LifeSource Health Line (Toll-Free): 1-888-726-9966
Step 1
Step 2
Step 3
SELECTING THE CORRECT CUFF SIZE
USE SMALL CUFF USE LARGE CUFFPROPER FIT RANGE
INDEX
Using the correct cuff size is important for an accurate reading. A cuff that is too large will produce a reading that is lower than the correct blood pressure; a cuff that is too small will produce a reading that is higher than the correct blood pressure. With your arm hanging at the side of your body, measure the circumference of your upper arm at the midpoint between the shoulder and elbow.
ARM SIZE
RECOMMENDED CUFF
SIZE
REPLACEMENT CUFF MODEL #
9.4" - 14.2" (24 - 36cm) Medium Cuff UA-280
14.2" - 17.7" (36-45cm) Large Cuff UA-281
NOTE: The LifeSource small cuff is not compatible with the UA-853 monitor.
Cuff Size Indicator On The Cuff
Our cuff has an indicator which tells you whether you are using the correct cuff size or not. Place the cuff on your arm (see Page E-6 to learn how to put the cuff on correctly) and if the Index Mark points within the Proper Fit Range, you are using the correct cuff size. If the Index points outside of the Proper Fit Range, contact A&D Medical at 1-888-726-9966 (in Canada, call Auto Control Medical at 1-800-461-0991) for more information on where to
obtain a cuff replacement.
NOTE: If the cuff size indicator falls on a borderline between two size categories, pick either one and make sure to use the same cuff size for each measurement.
In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991
E-5
!