LifeSource UA-767 User Manual

Trilingual Instruction Guide – MODEL UA-767
Blood Pressure Monitor
TM
One Step Auto-Inflation
WHAT DISPLAY SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . . 3
HOW 767 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
BEFORE YOU START . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SELECTING THE CORRECT CUFF . . . . . . . . . . . . . . . . . . . . . . 6
TAKING YOUR BLOOD PRESSURE . . . . . . . . . . . . . . . . 7 — 10
CHECK/ADJUST EXHAUST VELOCITY . . . . . . . . . . . . . 11 — 12
ABOUT BLOOD PRESSURE . . . . . . . . . . . . . . . . . . . . 13 — 15
BLOOD PRESSURE RECORD . . . . . . . . . . . . . . . . . . . . . . . . 16
IMPORTANT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . 17
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . 19
TABLE OF CONTENTS
?
TM
Congratulations. You have purchased a LifeSource
state-of-the-art blood pressure monitor, one of the most technologically advanced yet easy to use products available in the marketplace today. This LifeSource monitor is designed to make your daily regimen useful, and convenient.
Physicians agree that daily self-monitoring of blood pressure is an important way individuals can contribute to maintaining their cardiovascular health and preventing the serious consequences of hypertension left undiagnosed and untreated.
LifeSource has been manufacturing quality healthcare products for more than 20 years. Rest assured that we are committed to providing you and your family with monitoring devices specifically designed for high accuracy and ease of use. LifeSource—your source for a lifetime of health.
1
2
LifeSource Health Line (Toll-Free): 1-888-726-9966 LifeSource Health Line (Toll-Free): 1-888-726-9966
AIR SOCKET
MEASUREMENT IN PROGRESS
LOW BATTERY DISPLAY
SYSTOLIC DISPLAY
DIASTOLIC DISPLAY
STARTBUTTON
AIR CONNECTOR
CUFF
BATTERYCOMPARTMENT
ADJUSTMENT SCREW
BLACK PROTECTION CAP ON ADJUSTMENT SCREW
PRESSURE SWITCH
PULSE DISPLAY
MONITOR COMPONENTS
TUBE
Display Symbol
Recommended Action
Remain still and refrain from talking; measure­ment in progress.
Replace all batteries with new ones.
Check for air leakage; make sure cuff tube is properly connected to monitor and exhaust rate is in increments of 2 mmHg. to 5 mmHg
Try measurement again and remain very still.
Make sure cuff tube is properly connected to monitor, cuff is securely fastened and exhaust rate is between 2 mmHg and 5 mmHg. Make sure air connector is inserted properly into tube and monitor.
Condition/ Cause
Appears during measure­ment; blinks and beeps when pulse is detected.
Battery voltage is too low for monitor to work properly.
Appears when systolic and diastolic measure­ments are within 10 mmHg of each other.
Appears if pressure value is unstable due to movement during reading.
Appears when pressure value did not increase during cuff inflation:
1) cuff is not fastened
2) air connector is not connected properly.
MEASUREMENT IN
PROGRESS
LOW BATTERY
ERROR 2
ERROR 1
ERROR 3
MONITEUR
TUYAU DU BRASSARD
WHAT DISPLAY SYMBOLS MEAN
?
3
4
?
?
LifeSource Health Line (Toll-Free): 1-888-726-9966 LifeSource Health Line (Toll-Free): 1-888-726-9966
?
START
TM
UA-767
DIGITAL
BLOOD
PRESSURE
MONITOR
SYSTOLIC mmHg
DIASTOLIC mmHg
PUL / min
240 210 180 150
Using the correct cuff size is important for an accurate reading. A cuff that is too large will produce a reading that is lower than the correct blood pressure; a cuff that is too small yields a measurement that is higher. With your arm hanging at the side of your body, measure the circumference of your upper arm at the midpoint between shoulder and elbow.
To attach cuff, insert air connector at end of cuff tube into air socket on left side of monitor. Should you need to change the cuff size, the preset exhaust velocity rate may have to be adjusted (see page 11).
AIR CONNECTOR
ARM SIZE
RECOMMENDED CUFF SIZE
REPLACEMENT CUFF MODEL#
5.1” - 7.9” (13-20cm)
7.5” - 12.2” (19-31cm)
11.8” - 17.7” (30-45cm)
Small Medium Large
UA-279 UA-280 UA-281
SELECTING THE CORRECT CUFF
TUBE
You must install 4 type AA (1.5 volt) batteries and attach the cuff to the monitor before using it. To install batteries (or replace them if the “Low Battery” symbol appears on display), proceed as follows:
1. Remove battery compartment cover
by gently pushing down on arrow and sliding cover forward.
2. Put in top row of batteries first. Place
the batteries in compartment with positive (+) and negative (–) terminals matching those indicated in the compartment. Be sure batteries make contact with compartment terminals.
3. Replace cover by sliding it into
the compartment and gently pressing into place.
BEFORE YOU START
LifeSource Blood Pressure Monitors are easy to use, accurate and digitally display full measurement readouts. Our technology is based on the “oscillometric method” — a noninvasive blood pressure determination. The term “oscillation” refers to any measure of vibrations caused by the arterial pulse. The cuff is first inflated until the artery is fully blocked. Then, the monitor takes measurements while the cuff deflates. Our monitors examine the pulsatile pressure generated by the arterial wall as it expands and contracts against the cuff with each heartbeat.
HOW 767 WORKS
?
5
6
?
LifeSource Health Line (Toll-Free): 1-888-726-9966LifeSource Health Line (Toll-Free): 1-888-726-9966
AIR CONNECTOR