Lifebreath TFPC2000, TFP2000 User Manual

1 TFP 4 mounting brackets 4 hanging straps 2 oval collar connections 4 8/32” X 3/4” sheet metal screws 8 8/32” X 3/8” sheet metal screws 4 pieces of mounting foam 1 set of installation \ operating instructions 1 warranty card 1 wiring diagram
The TFP is equipped with a standard power supply, on a 5’ 5” cable. Lighted ON/OFF switch.
Materials Supplied
Electrical
* LEAVE FOR HOMEOWNER
NOTE: Due to ongoing research and product development, specifications,
ratings and dimensions are subject to change without notice.
TFP-06
0204
INSTALLATION MANUAL FOR TFP AIR CLEANER
TFP2000 (Wholehouse Model)
TFPC2000 (Portable Console Model)
WHOLEHOUSE AND PORTABLE
CONSOLE MODELS
ATTENTION
ATTENTION
The TFP can be installed in several different ways. Please read all suggested methods before attempting installation.
The furnace fan and/or HRV must operate continuously for Type 1 and Type 2 installations. If they do not operate continuously, then interlocking them electrically with the TFP is acceptable. Consult a certified electrician.
2
TFP Directly Connected to
Forced Air Heating System
1. Install 6” oval port collar (provided) on top and bottom of TFP (Fig. 1). Use (4) 8/32” X 3/8” screws (provided).
2. Remove protective backing from pieces of foam and stick them to the 4 corners of the TFP on the side being mounted against the plenum.
3. Remove the 4 mounting bolts from the back of the TFP cabinet. (Fig. 1)
4. Attach top and bottom mounting brackets (provided) vertical to the TFP cabinet and reinstall mounting bolts.
5. Lift the TFP into position. Edge of TFP must be
positioned on plenum to allow clearance needed for latches.
6. Install the (4) 8/32” X 3/4” mounting screws (provided) through the brackets and into position. Tighten and secure.
7. TFP should now sit securely against the plenum with the foam in between.
8. Cut 2 - 6” holes in the plenum. Install ducting to join TFP to the return air plenum (Fig. 2).
NOTE: Do not support the weight of the TFP on the duct. Duct must be open and not pinched.
NOTE: Due to possible noise transfer through the duct system, it may be preferable in some situations to hang the TFP a short distance from the plenum, and connect by running flexible ducting between them. Four nylon hanging straps are provided for this option.
Type 1 Installation
* Direct connect to furnace/air handler return, or hang separately and connect to plenum with flexible ducting.
TYPE 1 INSTALLATION
Figure 1
T F
P
Cold Air Return
Air flow direction
6" port collars
Access door
Power supply
Mounting bracket
Ducting (not included)
Clean (filtered) air port
Mounting bracket
Foam gaskets
FURNACE
Air Flow
Supply Plenum
Install plate here
1" Height
Figure 2
Round port bent to oval
Simply bend a standard duct fitting to the correct shape, and attach to the oval port using the same method as for a round port.
TFP
TFP
TFP
TFP air cleaner