Liebherr 7080 359-02, C 16 User Manual

Installation
Instructions
For Built-In NoFrost Combined
Refrigerator-Freezers
Instructions
de montage
Pour le combiné réfrigérateur-
congélateur NoFrost encastrable
Instrucciones
de instalación
Para conbinados frigorífico-
congelador NoFrost empotrables
C 16
CI 16
7080 359-02
IMPORTANT
PLEASE READ AND FOLLOW THESE INSTRUCTIONS
These instructions contain Warning and Caution statements.This information is important for safe and efficient installation.
Always read and follow all Warning and Caution statements!
WARNING
!
States a hazard that may cause serious injury or death if precautions are not followed.
CAUTION
!
Signals a situation where minor injury of product damage may occur if you do not follow instructions.
IMPORTANT
This highlights information that is especially relevant to a problem-free installation.
Make sure incoming voltage is the same as the unit rating.
To reduce the risk of fire, electric shock, or personal injury, installation wor k and electrical wir ing must be done by a qualified electrician in accordance with all applicable codes and standards, including fire­rated construction.
TO THE INST ALLER
It is very important that the guidelines and instructions are followed in the manual to ensure proper installation and operation of the unit.The Installation Guidelines section contains important information for making sure the installation is correct. Read and understand all the information in Installation Guidelines, and in this manual before the unit is installed.
A delight in freshness
C 16/CI 16
A delight in freshness
Table of Contents
1
C 16/CI 16
Contents Page
Features....................................................................................................... 2
Installation Guidelines
Area Requirements................................................................................ 3
Electrical Requirement........................................................................... 3
Customer’s Responsibility...................................................................... 3
Blocking For Safety................................................................................ 3
Unit V enting............................................................................................ 3
Reversing the Door Hinges................................................................... 3
Planning Information
Cabinet Opening Dimensions .................................................................4
Integrating Cabinetry
Framed Panels....................................................................................... 6
Overlay Panels....................................................................................... 7
Mounting the Upper Ventilation Grille........................................................ 10
Leveling the Refrigerator............................................................................ 11
Blocking for Safety ..................................................................................... 12
Door Stop Adjustment................................................................................ 13
Reversing Door Hinges.............................................................................. 14
Liebherr Warranty Plan.............................................................................. 17
FEATURES
2
C 16/CI 16
Figure 1
A delight in freshness
Operating and control elements
Butter and cheese compartment
Beverage Rack Adjustable door racks
Adjustable shelves
Gallon shelf
Vegetable bin
Drawers
Freezing chart
Adjustable-height unit
INSTALLATION GUIDELINES
3
C 16/CI 16
Area Requirements
Ver ify the following:
• Floors can support refrigerator’s weight plus approximately 1200 pounds (544 kg) of food weight.
• Finish kitchen floor height is level.Refrigerator must be shimmed to the floor level if the floor heights are not equal to make sure air vents are not obstructed.
• Remove anything attached to rear or side walls that can obstruct refrigerator opening.
• Cutout dimensions are accurate.
• Electrical outlet is in correct location.
Do not install this unit next to another refrigerator or freezer.This is important to prevent condensation or consequential damage from another unit.
Electrical Requirement
If codes require a separate grounding circuit to be used, have a qualified electrician install the circuit.
Do not ground to a gas pipe. Check with a qualified electrician if you are not sure the appliance is properly grounded. Do not have a fuse in the neutral or grounding circuit.
ELECTRICAL SHOCK HAZARD
• Electrically ground refrigerator.
• Do not use an extension cord.
• Failure to follow these instructions could result in fire or electrical shock.
ELECTROCUTION HAZARD
Electrical Grounding Required.This appliance is equipped with a three-prong (grounding) polarized plug for your protection against possible shock hazards.
DO NOT remove the round grounding prong from the plug.
DO NOT use a two-prong grounding adapter.
DO NOT use an extension cord to connect power to the unit.
Customer’s Responsibility
A 115 Volt, 60 Hz, 15 Amp (20 Amp for side-by-side installation) fused electrical supply is required.We recommend using a dedicated circuit for this appliance to prevent electrical over load. Follow the National Electrical Code and local codes and ordinances when installing the receptacle.
Blocking For Safety
The anti-tip brackets must be installed to prevent the unit from tipping after it is installed. Refer to Blocking For Safety.
Unit Venting
DO NOT restrict the air flow. Air flow must be provided for the unit to operate. The factory air vents provide 31 square inches (200 cm
2
) of air flow. If you are replacing the factory air vents with an overlay, the air flow must be the same or greater than the factory air vents.
Reversing the Door Hinges
If the hinges and door handles are reversed, you must obtain the Reverse Set.The Reverse Set is not included with the unit. Contact your Liebherr retailer, only for CI 16 unit. The door handles must be installed before the screw covers are installed.If you fail to install the handles before the screw covers, you can damage the covers.The screw covers are taped to the unit door during shipping. Use care when removing the covers.
A delight in freshness
WARNING
!
WARNING
!
WARNING
!
PLANNING INFORMATION
4
C 16/CI 16
A delight in freshness
Cabinet Opening Dimensions
Figure 2
Allow units to open a minimum of 90° to prevent problems removing drawers.With the door opening 90°, you may have to move drawers slightly to clear the door interior.
Refer to the minimum door clearances in the Pre­Installation Specifications chart.
• Allow for a minimum 2" (5.08 cm) filler, for corner installations, so the door can open to 90°. If you’re using raised panels, consider using a wider filler.
• Use a filler strip when units are installed side by side.The width of this filler strip will vary depending on the configuration and panels used.
• Be sure to add the filler strip width to the finished rough-in dimension. In any side by side installation, add an additional 1/2" (1.27 cm) to the combined numbers.
IMPORTANT
Refer to the scaled illustrations at the end of this section for specifics on door openings and filler size alternatives.
ELECTRICAL OUTLET LOCATION
7" (17.8 cm)
6" (15.2 cm)
75-1/2" (192 cm)
83-3/4" (212.7 cm)
LOCATE WATER SUPPLY WITHIN BOTTOM SHADED AREA
18" (45.7 cm)
24" (61 cm)
29-1/2" (75 cm)
3" (7.6 cm)
PLANNING INFORMATION
5
C 16/CI 16
A delight in freshness
Figure 3
81" (206 cm)*
83.9" (213 cm)*
30" (76.2 cm)
Air Vent
26" (66 cm)
24" (60,9 cm) - C 16
24-1/2" (62 cm) - CI 16
30" (76.2 cm)
29" (73.7 cm)
DOOR SWING CLEARANCE
Air Vent
90˚
130˚
22.9" (58.2 cm)
19" (48.2 cm)
52.7" (134 cm)
1.8" (4.6 cm)
47" (449.5 cm)
* Overall height can be increased 5/8" (1.59 cm) by turning the adjustable roller base.
INTEGRATING CABINETRY - CI 16 ONLY
6
C 16/CI 16
A delight in freshness
Framed Panels
If the thickness of the custom panels is less than 1/4" (0.635 cm), they must be backed up with a sheet of shim material to build the total thickness to 1/4" (0.635 cm). If the panel is thicker than 1/4" (0.635 cm), an edge must be routed around the panel to ensure a proper fit.
Figure 4
IMPORTANT
If you are replacing the factory air vents with an overlay, DO NOT restr ict the air flow.The air flow must be the same or greater than the factory air vents of 31 square inches (200 cm
2
).
The door handles must be installed before the screw covers are installed. If you fail to install the handles before the screw covers, you can damage the covers.The screw covers are taped to the unit doors during shipping. Use care when removing covers.
The door panel weight must not exceed 25 lb (11.3 kg).
Panels 1/4" (0.635 cm) thick or less
Trim reveal 1/4" min.
FRAMED PANEL SPECIFICATION
28.4" (72.1 cm)
1/4" Panel
Panels thicker than 1/4" (0.635 cm)
Trim reveal 1/4" min.
Rout to 1/4" thickness
Refrigerator
Panel
Freezer
Panel
28.9" (73.5 cm) 46.3" (117.6 cm)
INTEGRATING CABINETRY - CI 16 ONLY
7
C 16/CI 16
A delight in freshness
Overlay Panels
The overlay design line allows decorative panels to cover the door trim for a more seamless appearance that blends with the design of the room.To achieve this look, the most common way is to work with three panels, the decorative overlay panel, a 0.10" (0.25 cm) spacer panel and a 1/4" (0.635 cm) backer panel.
Figure 5
Depending on your cabinet manufacturer, this could be one panel routed for different dimensions or, more likely, three different panels.
IMPORTANT
If you are replacing the factory air vents with an overlay, DO NOT restr ict the air flow.The air flow must be the same or greater than the factory air vents of 31 square inches (200 cm
2
).
The door handles must be installed before the screw covers are installed. If you fail to install the handles before the screw covers, you can damage the covers.The screw covers are taped to the unit doors during shipping. Use care when removing covers.
The door panel weight must not exceed 25 lb (11.3 kg).
Overlay Panel 28.7" (72.9 cm) Spacer Panel 27.4" (69.6 cm) Backer Panel 28.2" (71.7 cm)
Refrigerator
Panel
Freezer
Panel
Spacer Panel
Overlay Panel 47.6" (120.9 cm)
Spacer Panel 45.3" (115 cm)
Backer Panel 46.3" (117.6 cm)
0.1" (0.25 cm)
0.0625" (0.16 cm)
Overlay Panel
1/4" (0.635 cm) Backer Panel
0.6" (1.5 cm)
Overlay Panel 29.2" (74.3 cm)
Spacer Panel 27.9" (70.9 cm)
Backer Panel 28.9" (73.5 cm)
INTEGRATING CABINETRY - CI 16 ONLY
8
C 16/CI 16
Figure 6
A delight in freshness
A = 1/4" (0.6 cm) B = 1/2" (1.3 cm) C = 3/4" (1.9 cm) D = 1" (2.5 cm) E = 1-1/4" (3.2 cm) F = 1-1/2" (3.8 cm) G = 1-3/4" (4.4 cm) H = 2" (5.1 cm) I = 2-1/4" (5.7 cm) J = 2-1/2" (6.4 cm) K = 2-3/4" (7.0 cm) L = 3" (7.6 cm)
9
C 16/CI 16
A delight in freshness
INTEGRATING CABINETRY - CI 16 ONLY
The factory setting for the door to swing open is 130°. Use this illustration to ensure other cabinets or counters do not interfere with the door opening.
Frameless cabinets:The casing trim overlaps the cabinets at the side and top.Cabinets may require filler strips to prevent interference with the cabinet door swing.The door opening must allow for filler strips.
(
Figure 7 - CI 16 only
23-5/8" (60 cm)
to rear of Liebherr
M
L
K
J
I
H G
A
B
E
F
C
D
I
J
G
H
K
L
Nominal Overall Width of Liebherr
Door closed
Overlay Panel
3/4" Nominal Size)
H
I
J
K
L
Door Open @ 130˚
A = 3" (7.6 cm) B = 2-3/4" (7 cm) C = 2-1/2" (6.4 cm) D = 2-1/4" (5.8 cm) E = 2" (5.1 cm) F = 1-3/4" (4.5 cm) G = 1-1/2" (3.8 cm) H = 1-1/4" (3.2 cm) I = 1" (2.5 cm) J = 3/4" (1.9 cm) K = 1/2" (1.3 cm) L = 1/4" (0.6 cm) M = 0"
INTEGRATING CABINETRY - CI 16 ONLY
10
C 16/CI 16
Figure 8
A delight in freshness
Nominal Overall Width of Liebherr
A B
C D E F
L
H
K
J
I
D
G
C
F
E
B
A
Door Open 130˚
Door Closed
A = 1/4" (0.6 cm) B = 1/2" (1.3 cm) C = 3/4" (1.9 cm) D = 1" (2.5 cm) E = 1-1/4" (3.2 cm) F = 1-1/2" (3.8 cm) G = 1-3/4" (4.4 cm) H = 2" (5.1 cm) I = 2-1/4" (5.7 cm) J = 2-1/2" (6.4 cm) K = 2-3/4" (7.0 cm) L = 3" (7.6 cm)
11
C 16/CI 16
A delight in freshness
INTEGRATING CABINETRY - CI 16 ONLY
The optional setting for the door to swing open is 90°. Use this illustration to ensure other cabinets or counters do not interfere with the door opening.
Frameless cabinets:The casing trim overlaps the cabinets at the side and top.Cabinets may require filler strips to prevent interference with the cabinet door swing.The door opening must allow for filler strips.
Figure 9 - CI 16 only
23-5/8" (60 cm)
to rear of Liebherr
Main Frame
A B C D E F G
Nominal Overall Width of Liebherr
Door closed
Overlay Panel
(3/4" Nominal Size)
F
E
DCB
Door Open 90˚
A = 0" (0 cm) B = 1/4" (0.6 cm) C = 1/2" (1.3 cm) D = 3/4" (1.9 cm) E = 1" (2.5 cm) F = 1-1/4" (3.2 cm) G = 1-1/2" (3.8 cm)
INTEGRATING CABINETRY - CI 16 ONLY
12
C 16/CI 16
Figure 10
A delight in freshness
Nominal Overall Width of Liebherr
A B
C D E F
L
H
K
J
I
D
G
C
F
B
E
A
Door Closed
A = 1/4" (0.6 cm) B = 1/2" (1.3 cm)
Door Open 90˚
C = 3/4" (1.9 cm) D = 1" (2.5 cm) E = 1-1/4" (3.2 cm) F = 1-1/2" (3.8 cm) G = 1-3/4" (4.4 cm) H = 2" (5.1 cm) I = 2-1/4" (5.7 cm) J = 2-1/2" (6.4 cm) K = 2-3/4" (7.0 cm) L = 3" (7.6 cm)
13
C 16/CI 16
A delight in freshness
MOUNTING THE UPPER
VENTILATION
GRILLE
Figure 11
Position the ventilation grille at the top of the installation frame and attach it later with countersunk screws (4 pieces, provided).Make sure the grille fits flush laterally with the installation frame.
IMPORTANT
If you are replacing the factory air vents with an overlay, DO NOT restr ict the air flow.The air flow must be the same or greater than the factory air vents of 31 square inches (200 cm
2
).
Screws
Grille
Installation Frame
14
C 16/CI 16
A delight in freshness
LEVELING THE REFRIGERATOR
1. Loosen the lower ventilation grille screws (Fig. 12, 1).
The height can be adjusted in front by twisting the leveling wheels (Fig. 12, 2).
2. Twist the adjusting bolt (Fig. 12, 3) to set up the back of the refrigerator.
3. Rotate leveling until firmly in place against the floor.
4. Align refrigerator with sides of kitchen cabinets by adjusting leveling wheels and the supports.
5. Install the ventilation grille.
Figure 12
3
2
2
1
3
2
2
15
C 16/CI 16
A delight in freshness
BLOCKING FOR SAFETY
1. Secure the refrigerator in place so it does not tip forward when the fully stocked door is opened.
2. Measure the distance from the floor to the upper edge of the unit.
3. Locate and mark two wall studs against the wall where the refrigerator will be located.The space between the unit top and the bottom of the brackets must not be more than 1/4" (0.635 cm).
4. Make sure the screws extend a minimum of 1" (2.54 cm) into each of the wall studs.
5. Make sure the anti-tip brackets extend at least 3" (7.62 cm) over the unit and are securely in place.
IMPORTANT
The anti-tip brackets can be installed in either direction or closer together.Always position the anti-tip brackets as wide apart as possible, but make sure they are anchored to two studs.
6. Using the front and rear levelers, raise the unit until it makes contact with the brackets. Make sure the front levelers are firmly on the floor to prevent appliance from tipping forward.
IMPORTANT
If your unit is positioned in between the wall studs, a board can be secured to the wall. Make sure the board is secured to the studs with screws that will penetrate into the studs a minimum 1" (2.54 cm).The board should be a minimum of 1" x 6" (2.54 cm x 15.24 cm) and long enough to secure both ends to the wall studs.
Figure 13
Screws
Bracket
Wall Stud
min 3"
16
C 16/CI 16
A delight in freshness
DOOR STOP ADJUSTMENT
Figure 15
Select between two opening angles: 130° and 90°. Your appliance was delivered with a door opening of 130°. If 90° opening angle is required, use this procedure:
1. Close the refrigerator door.
2. Turn screw (1), provided, into bore (2). Use the same procedure to set up the freezer door.
Figure 14
1
2
2
1
NOTES
17
C 16/CI 16
A delight in freshness
18
C 16/CI 16
A delight in freshness
REVERSING DOOR HINGES - CI 16
13. Mount the right installation frame (10) on the other side. Discard the two other frames (11).
14. Mount the two enclosed frames (12) on the right side. Do not forget the angle bracket corner (13).
15. Lock the angle bracket (13) with the installation frame.
16. Remove the door mounting from the refrigerator and attach it on the other side (14).
17. Remove hinge sockets (15).
18. Remove door change frames (16).
19. Pull out shrouded-type panel (17) at the door change frame at the handle side.
20. Remove screws (19).
21. Remove handle (18).
22. Remove the other door change frames (20) and mount them on the opposite side.
23. Insert handle brackets (21) again into the slots and attach handle.
24. Push shrouded-type panel (22) in the door change frames.
25. Mount door change frames above and down (23).
26. Insert hinge socket (24) into the frames.
27. Attach hinge socket (25) with screws to the door.
28. Follow these instructions to change the other door.
29. Insert spacers (26) for the upper door.
30. Attach center door fixture (27).
31. Place down lower door again on the lower door mounting bracket.
32. Insert the metal pin (28) into the sleeve.
33. Position other door on the door mounting center.Use other spacer (29) and attach door with hinge bolt (30).
34. Mount the upper ventilation grille (Figure 11).
IMPORTANT
If the hinges and door handles are reversed, you must obtain the Reverse Set. The Reverse Set is not included with the unit.
Changing the door stop must be made by two people to prevent personal injury and damage to the doors.
1. Remove the upper ventilation grille if already installed.
2. Remove the screw (1) at the door fixture.
Secure door to prevent personal injury and to prevent the door from falling down.
3. Remove spacers (2). The door can now be lifted and placed on the
floor.
4. Pull out the bearing pin (3) at the door fixture center.
Secure door to prevent personal injury and to prevent the door from falling down.
5. Lift the door and place it on the floor.
6. Remove the door fixture (4).
7. Loosen the screws at the door fixture.
8. Remove the screw (5) at the lower door fixture and turn it into the other bore.
The door fixture down can be mounted again on the other side (6).
9. Pull out plastic sleeve and assemble on the opposite side of the bracket (7).
10. Remove both screws (8) at the back of the installation frame.
11. Remove the 18 mounting screws (9) to dismantle the installation frame.
12. Mount the installation frame.
CAUTION
!
CAUTION
!
CAUTION
!
19
C 16/CI 16
A delight in freshness
REVERSING DOOR HINGES - CI 16
Figure 16
7X
3
6
12
11
7X
10
10
4
7
7X
1
2
5
9
7X
8
17
16
13
20
14
18
21
15
19
22
20
C 16/CI 16
A delight in freshness
REVERSING DOOR HINGES - CI 16
Figure 17
Figure 18
24
27
28
25
26
30
29
NOTES
21
C 16/CI 16
A delight in freshness
REVERSING DOOR HINGES - C 16
22
C 16/CI 16
IMPORTANT
If the hinges and door handles are reversed, you must obtain the Reverse Set. The Reverse Set is not included with the unit.
Changing the door stop must be made by two people to prevent personal injury and damage to the doors.
1. Remove the upper ventilation grille if already installed.
2. Remove the screw (1) at the door fixture.
Secure door to prevent personal injury and to prevent the door from falling down.
3. Remove spacers (2). The door can now be lifted and placed on the
floor.
4. Pull out the bearing pin (3) at the door fixture center.
Secure door to prevent personal injury and to prevent the door from falling down.
5. Lift the door and place it on the floor.
6. Remove the door fixture (4).
7. Loosen the screws at the door fixture.
8. Remove the screw (5) at the lower door fixture and turn it into the other bore.
The door fixture down can be mounted again on the other side (6).
9. Pull out plastic sleeve and assemble on the opposite side of the bracket (7).
10. Remove both screws (8) at the back of the installation frame.
11. Remove the 18 mounting screws (9) to dismantle the installation frame.
12. Mount the installation frame.
13. Mount the right installation frame (10) on the other side. Discard the two other frames (11).
14. Mount the two enclosed frames (12) on the right side. Do not forget the angle bracket corner (13).
15. Lock the angle bracket (13) with the installation frame.
16. Remove the door mounting from the refrigerator and attach it on the other side (14).
17. Remove hinge sockets (15).
18. Remove screws (16).
19. Remove handle (17).
20. Insert handle brackets (18) again into the slots, on the opposite side, and attach handle.
21. Attach hinge socket (19) with screws to the door.
22. Follow these instructions to change the other door.
23. Insert spacers (20) for the upper door.
24. Attach center door fixture (21).
25. Place down lower door again on the lower door mounting bracket.
26. Insert the metal pin (22) into the sleeve.
27. Position other door on the door mounting center.Use other spacer (23) and attach door with hinge bolt (24).
28. Mount the upper ventilation grille (Figure 11).
A delight in freshness
CAUTION
!
CAUTION
!
CAUTION
!
REVERSING DOOR HINGES - C 16
23
C 16/CI 16
Figure 19
A delight in freshness
7X
3
6
12
11
7X
10
10
4
7
7X
1
2
5
9
7X
8
16
17
14
15
13
18
REVERSING DOOR HINGES - C 16
24
C 16/CI 16
Figure 20
A delight in freshness
22
19
24
23
20
21
Loading...
+ 58 hidden pages