IMPORTANT SAFETY INSTRUCTIONS
WARNING: Do not attempt to service this product yourself. Opening or removing the
cover may expose you to dangerous voltages, even when the AC cord is disconnected
1. SAVE THESE INSTRUCTIONS. THIS MANUAL CONTAINS IMPORTANT
2. This product is not intended for use with life support and other U.S. FDA
3. CAUTION: A BATTERY PRESENTS A RISK OF ELECTRICAL SHOCK OR BURN
4. WHEN REPLACING THE BATTERIES, USE THE SAME NUMBER AND TYPE OF
5. Read all safety and operating instructions before operating the UPS and battery
6. Turn the UPS and battery cabinet off and unplug them before cleaning. Use only a soft
7. The UPS is designed for data processing equipment. Do not plug appliances, such as
8. WARNING: Do not modify input cable. Consult your dealer if connector does not
9. The Battery Cabinet is equipped with a grounded NEMA 5-15, or a grounded Schuko-
10. Route power supply cords so they are not walked on or pinched.
11. Never block or insert any object into the ventilation holes or other openings. Maintain a
12. Servicing of batteries should be performed or supervised by personnel knowledgeable
13. CAUTION: Do not open or mutilate the batteries. Released electrolyte is harmful to
14. CAUTION: This equipment has been tested and complies with limits for a Class A
15. This equipment can be operated by individuals without previous training.
from the electrical outlet. Refer all servicing to qualified service personnel.
INSTRUCTIONS THAT SHOULD BE FOLLOWED DURING INSTALLATION AND
MAINTENANCE OF THE BATTERY CABINET AND UNINTERRUPTIBLE POWER
SYSTEM (UPS).
designated “critical” devices. See Limited Warranty.
FROM HIGH SHORT CIRCUIT CURRENT. OBSERVE PROPER PRECAUTIONS.
BATTERIES. PROPER DISPOSAL OF BATTERIES IS REQUIRED. REFER TO
YOUR LOCAL CODES FOR DISPOSAL REQUIREMENTS.
cabinet. Adhere to all warnings on the unit and in this manual. Follow all operating and
user instructions.
cloth, never liquid or aerosol cleaners.
hair dryers, heaters, vacuum cleaners, or electric drills, into the UPS output
receptacles. The UPStation GXT™ LRT has a nominal voltage rating of 96VDC. The
UPStation GXT™ LRT is designed to operate only with the Liebert UPStation GXT
1800/2000 and 2700/3000 VA rack tower (RT) UPS units with a sequential serial
number 9915003001AF1T1 or greater. The LRT cabinets are capable of being
paralleled in order to achieve longer run times (up to 8+ hours).
match the utility receptacle. The UPS and Battery Cabinet must be grounded at all
times while in use. Turn the UPS and Battery Cabinet off before unplugging them, or
the safety ground will be removed. Operate Battery Cabinet only from a properly
grounded 120 or 230 VAC outlet (2 wire plus ground).
type input power plug (depending upon input voltage). Do not defeat the safety
purpose of this plug. If unable to fully insert the plug into the wall outlet, contact a
qualified electrician for assistance.
clearance of four (4) inches in front and rear of the Battery Cabinet for proper airflow
and cooling.
of batteries and the required precautions. Refer all servicing to qualified service
personnel.
skin and eyes and may be toxic.
digital device, pursuant to Subpart B of Part 15 of FCC rules; and the CE EMC
directive. These limits provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy. If it is not installed and used in
accordance with the instruction manual, it may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause
harmful interference that the user must correct at their own expense.