Liebert 350-500 VA User Manual

PowerSure™ PST
POWER AVAILABILITY
USER MANUAL
350-500 VA
120V
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . 1
Top and Side Views of UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Transient Voltage Surge Suppression (TVSS) & EMI / RFI
Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Transfer Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Battery Charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
WHATS INCLUDED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
CONTROLS AND INDICATORS. . . . . . . . . . . . . . . . . . . . . . . . . 10
ON/OFF/ Alarm Silence Button . . . . . . . . . . . . . . . . . . . . . . . . 10
Status Indicators: Utility/Battery, Fault . . . . . . . . . . . . . . . . . 11
Utility/Battery Indicator (Green) . . . . . . . . . . . . . . . . . . . . . . . . . 11
Site Wiring Fault Indicator (Amber) . . . . . . . . . . . . . . . . . . . . . . . 11
Fault Indicator (Red) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Location and Status of Indicators . . . . . . . . . . . . . . . . . . . . . . . . . 11
MODES OF OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Battery Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
COMMUNICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
USB Interface Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Data Line Protection Connectors . . . . . . . . . . . . . . . . . . . . . . . 13
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Cleaning the UPS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Maintaining Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Guide to Status Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Troubleshooting Chart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Battery Run Times. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Product Warranty Registration. . . . . . . . . . . . . . . . . . . . . . . . . 18
i

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS
This manual contains important safety instructions that should be fol­lowed during the installation and maintenance of the Uninterruptible Power System (UPS) and its batteries. Please read this manual thor­oughly before attempting to install or operate this UPS.
Read all safety, installation, and operating instructions before operat­ing the UPS. Adhere to all warnings on the unit and in this manual. Follow all operating and user instructions.
This equipment is designed for Commercial, Industrial or Residential use. Liebert Corporation neither recommends nor knowingly sells this product for use in life support applications or with other designated critical devices.
This equipment can be installed and operated by individuals without previous training.
WARNING
!
SAFETY PRECAUTIONS
• To prevent the risk of fire or electric shock, install the UPS in a temperature and humidity controlled room, free of conductive contaminants, moisture, flammable liquids, gases and corrosive substances.
• Operate the UPS only from a properly grounded (earthed) 120VAC, 60Hz AC supply.
• To reduce the risk of electric shock, do not remove the cover, as it has no user-serviceable parts inside except the internal battery pack. Some components are live, even when AC power is disconnected. For service, contact a qualified technician.
1
CAUTION
!
Although your UPS has been designed and manufactured to assure personal safety, improper use may result in electrical shock or fire. To ensure safety, please observe the following rules:
• Turn off and unplug your UPS before cleaning. Do not use liquid or aerosol cleaners. A dry cloth is recommended to remove dust from the surface of your UPS.
• Do not install or operate your UPS in or near water.
• Do not place your UPS on an unstable cart, stand or table.
• Do not place your UPS in direct sunlight or near heat emitting sources.
• Never block or insert any objects into the ventilation holes or other openings of the UPS. Keep all vents free of dust accumulation that could restrict airflow.
• Do not place UPS power cord in any area where it may be damaged by heavy objects.
• Placing magnetic storage on the top of the UPS may result in data corruption.
CAUTION
!
If your UPS demonstrates any of the following conditions, turn off and unplug your UPS from the outlet and contact your local dealer, Liebert representative, or Liebert Worldwide Support Group.
• The power cord is damaged.
• Liquid has been spilled on the UPS.
• The circuit breaker or fuse opens frequently.
• The UPS does not operate in accordance with the user manual.
Provided is a USB cable for connection to a computer. Store in a safe place if not required at this time.
2
CONDITIONS OF USE: The input receptacle must be within 6 feet (1.8 meters) of the UPS.
Your UPS provides conditioned power to connected equipment. Maxi­mum load must not exceed that shown on UPS rating label. If uncer­tain, consult your local dealer, Liebert representative or the Liebert Worldwide Support Group.
The equipment can be installed and operated by individuals without previous training.
CAUTION
!
BATTERY HANDLING PRECAUTIONS Servicing of batteries should be performed or supervised by
personnel knowledgeable of batteries and required precautions. Keep unauthorized personnel away from the batteries.
A battery can present a risk of electrical shock and high short-circuit current. The following precautions should be observed when working on batteries:
• Remove watches, rings, and other metal objects.
• Use tools with insulated handles.
• Do not dispose battery or batteries in a fire. The battery may explode.
• Do not open or mutilate the battery or batteries. Released electrolyte is harmful to skin and eyes. It may be toxic.
• When replacing the battery, use same number and type of battery as the suitable recommended type of battery listed in specification table in back of this manual.
• Handle, transport and recycle batteries in accordance with local regulations.
3

INTRODUCTION AND SYSTEM DESCRIPTION

Congratulations on your choice of the Liebert PowerSure™ PST Unin­terruptible Power System (UPS). It provides filtered AC power to sen­sitive electronic equipment and other critical loads.
The PowerSure PST is an off-line UPS designed for desktop applica­tions. It provides perfect one-to-one power protection for electronic equipment such as PCs, point-of-sale displays, home office equipment and similar electronic gear. The PowerSure PST is available in two (2) sizes: 350 and 500VA at 120VAC.
PowerSure PST models are available for 120VAC and 230VAC supply voltages and loads. Please verify that this model matches your AC Utility and load voltage requirements.
NOTE
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment uses, generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference with radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the UPS and the receiver.
• Connect the UPS into an outlet on a circuit different from the one on which the receiver is connected.
4