To change purchase information on Tag, perform the following steps :
1.Put remote controller near center of Tag‟s display
2.Press and hold „Registration‟ button on remote controller until Red LED off
(about 0.5 seconds)
3.When Tag is successfully received „Registration‟ data from remote controller, Tag‟s
display will be changed to “Connected” for a few minutes. That means Tag hides
purchase image to read Tag‟s IEEE MAC address through the Barcode scanner.
4.In NMS Client, download new purchase image to the Tag in registration status
5.When image downloading is finished successfully, Tag‟s display will be changed to new
purchase image
Case1) If image downloading is failed, Tag‟s display will be changed to “Busy”.
After “Alive Time”, this Tag will be download new purchase image again
Copyrightⓒ. 2018. All Rights Reserved.
1. Overview
Remote control device provides customer with several functions as below
Waking Tag up from sleep mode
Updating new purchase image on Tag
Deleting purchase image on Tag
Returning a Tag to be factory settings
대외비 2급
Display Area
A remote controller or
a NFC Device contact point for communication.
•
Button Function
Profile Hook
Battery Cover
Two buttons provide customer with several functions as below
- Waking Tag up from sleep mode
- Updating new purchase image on Tag
- Changing purchase image on Tag
Registration
Keep Alive
Copyrightⓒ. 2018. All Rights Reserved.
Next Image
< Button Function>
3. Deleting purchase information on Tag
☜
대외비 2급
To release(delete) purchase information on Tag, perform the following steps :
1.Put remote controller near center of Tag display
2.Press and hold „Release‟ button until red LED off (about 0.5 seconds)
3.If Tag was received „Reset‟ command from remote controller, Tag will delete
purchase information and Tag‟s display will be changed to“Ready”
4.After step.3, Tag goes to deep sleep mode and doesn‟t communicate with gateway
until receiving „Keep Alive‟ or „Registration‟ data from remote controller
Copyrightⓒ. 2018. All Rights Reserved.
4. Waking Tag up
대외비 2급
Image 1
Image 2
☜
To wake Tag up from sleep mode, perform the following steps :
1.Put remote controller near center of Tag display
2.Press and hold „Keep Alive‟ button until Red LED off (about 0.5 seconds)
3.Tag will wake up and goes to next step. It‟s depends on connection information with gateway
case1) If this Tag wasn‟t connected with a gateway before sleep mode, go to 4-1
case2) If this Tag was connected with a gateway before sleep mode, go to 4-2
4-1. Searching gateway and goes to the next step. it‟s depends on searching resultscase1) If Tag was successfully connected, Tag‟s display will be changed to “Ready”case2) If Tag wasn‟t connected, Tag‟s display(may be “Ready”) will be refreshed
4-2. Sending „Keep Alive‟ packet to gateway and Tag will go to sleep mode again
case1) If Tag was received response from gateway, this Tag will go to “sleep mode” until
the specified time in gateway. After “sleep mode”, this Tag will send “Keep Alive” Packet to
gateway again.
case2) If Tag wasn‟t received response from Gateway, this Tag will retry three times. After that,
Tag‟s display will be changed to “Disconnected”. Also this Tag will perform a whole channel scan
every five minutes.
.
Copyrightⓒ. 2018. All Rights Reserved.
5. Returning a Tag to be factory settings
2016.10.20 14:34:59
대외비 2급
353,003
☜
To make a Tag to be factory reset status, perform the following steps :
1.Put remote controller near center of Tag display
2.Press and hold „Reset‟ button until Red LED off (about 0.5 seconds)
3.If Tag was received „Reset‟ command from remote controller, Tag goes back to factory
settings and Tag‟s display will be changed to“Ready”
4.After step.3, Tag goes to deep sleep mode and doesn‟t communicate with gateway
until receiving „Keep Alive‟ or „Registration‟ data from remote controller
case1) If Tag was received “Keep Alive” or “Registration” command from remote
controller, this Tag will perform a whole channel scan.
case2) If Tag was received “Reset” or “Release” command from remote controller,
Tag‟s display will be changed to “Ready” again
Copyrightⓒ. 2018. All Rights Reserved.
6. Tag status
Symbol Mode Image
Deep Sleep Mode
Connected with Gateway
대외비 2급
Disconnected with Gateway
Battery discharge
(the battery needs to be replaced)
Image download Failure(“Busy”)
Copyrightⓒ. 2018. All Rights Reserved.
Regulation Information
Trade name:
Manufacturer: LG Innotek Co., Ltd.
(Jangduk-dong) 26, Hanamsandan 5beon-ro, Gwangsan-gu, Gwangju, 62229, Korea
Model name: REBL-MZ29E
Operating frequency: 2405 MHz ~ 2480 MHz for Zigbee, 13.56 MHz for NFC (Receiving only)
Maximum transmit power: 10 dBm for Zigbee
Can be contacted via website: www.lginnotek.com
FCC Compliance Statement (for products subject to Part 15)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
Caution: Any changes or modifications to the equipment not expressly approved by the party responsible for
compliance could void user’s authority to operate the equipment. This appliance and its antenna must not be
co-located or operation in conjunction with any other antenna or transmitter.
A minimum separation distance of 20 cm must be maintained between the antenna and the person for this
appliance to satisfy the RF exposure requirement.
CE RF Radiation Exposure Statement
Caution: This equipment complies with European RF radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of 20 centimeters
between the radiator and your body. This transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.
Caution
Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the
instructions.
EU Representative
LG Innotek Co., Ltd. Am Limespark 2 (Innovapark) 65843 Sulzbach am Taunus, Germany
적합성 평가 정보
적합성평가를 받은 자의 상호명 : 엘지이노텍 (주)
기자재 명칭 : 특정소출력 무선기기(무선데이터통신시스템용 무선기기)
모델명 : REBL-MZ29E
제조자 및 제조국가 : 엘지이노텍 (주) / 한국
제조연월 : 제품에 별도 표기
인증번호 : R-C-LGW-REBL-MZ29E