LG ZRUN050LSS0 User Manual

MFL69171217
Rev.03_081920
Copyright © 2019 - 2020 LG Electronics Inc. All Rights Reserved.
OWNER’S & INSTALLATION MANUAL
AIR CONDITIONER
Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly.
Original instruction
[Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands [Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA Customer information centre AUSTRALIA : 1300 54 2273 / NEW ZEALAND : 0800 54 2273
This manual is the simplified version of original manual. You can obtain the original manual from website.
MALTI
PORTUGUÊS
ENGLISH
SLOVENČINA
SLOVENŠČINA
LATVIEŠU VALODA
LIETUVIŲ KALBA
GAEILGE
ITALIANO
MAGYAR
БЪЛГАРСKИ
ESPAÑOL
FRANÇAIS
SRPSKI
HRVATSKI
DEUTSCH
ΕΛΛΗΝΙΚΆ
SVENSKA
МАКЕДОНСКИ
SHQIP
BOSANSKI
ČEŠTINA
NORSK
NEDERLANDS
SUOMI
POLSKI
DANSK
LIMBA ROMÂNĂ
EESTI KEEL
2
ENGLISH
Airborne Noise Emission
The A-weighted sound pressure emitted by this product is below 70 dB.
The noise level can vary depending on the site.
The figures quoted are emission level and are not necessarily safe working levels.
Whilst there is a correlation between the emission and exposure levels, this cannot be used reliably to determine whether or not further precautions are required.
Factor that influence the actual level of exposure of the workforce include the characteristics of the work room and the other sources of noise, i.e. the number of equipment and other adjacent processes and the length of time for which an operator exposed to the noise. Also, the permissible exposure level can vary from country to country.
This information, however, will enable the user of the equipment to make a better evaluation of the hazard and risk.
Limiting concentration
Limiting concentration is the limit of Freon gas concentration where immediate measures can be taken without hurting human body when refrigerant leaks in the air. The limiting concentration shall be described in the unit of kg/m3(Freon gas weight per unit air volume) for facilitating calculation.
Limiting concentration: 0.44 kg/m3(R410A)
Total amount of replenished refrigerant
Refrigerant concentration(kg/m3) =
in refrigerant facility (kg)
Capacity of smallest room
where indoor unit is installed (m3)
Model Designation
Product information
• Product Name : Air conditioner
• Model Name :
Product Sales Name Model Factory Name
ZRab***cde#z series
a = U (Air cooled system), W (Water cooled system) b = N (Heat pump), B (Heat recovery), V (Cooling only),
M ( Heat recovery & Heat pump) c = L (3Phase model), G (Single phase Model) d = T (Top discharge), R(Right discharge),
L (Left discharge), A(Basic), S(Side discharge) e = S (Basic function),
E (Additional function related to performance) or Blank
B (HS Model) *** = Numeric; (Cooling capacity) # = Numeric; (Series No) z=
A:PFC model, B:Active Filter model(Only use Multi V mini model)
- Additional Information : serial number is refer to the barcode on the product.
- Max Allowable pressure High side : 4.2 MPa / Low Side : 2.4 MPa (Refrigerant : R410A)
- Max Allowable pressure High side : 4.32 MPa / Low Side : 2.4 MPa (Refrigerant : R32)
- Max Allowable water temperature High side : 45 °C / Low side : 10 °C (ARWb***cde#z serises)
3
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product.
WARNING
!
It can result in serious injury or death when the directions are ignored.
CAUTION
!
It can result in minor injury or product damage when the directions are ignored.
WARNING
!
• Installation, repairs or breakdown made by unqualified persons can result in hazards to you and others.
• The information contained in the manual is intended for use by a qualified service technician familiar with
safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment malfunction,
property damage, personal injury and/or death.
Installation
• Have all electric work done by a licensed electrician according to "Electric Facility Engineering Standard"
and "Interior Wire Regulations" and the instructions given in this manual and always use a special circuit.
- If the power source capacity is inadequate or electric work is performed improperly, electric shock or fire may result.
• Ask the dealer or an authorized technician to install the air conditioner.
- Improper installation by the user may result in water leakage, electric shock, or fire.
• Always ground the product.
- There is risk of fire or electric shock.
• Always install a dedicated circuit and breaker.
- Improper wiring or installation may cause fire or electric shock.
• For re-installation of the installed product, always contact a dealer or an Authorized Service Center.
- There is risk of fire, electric shock, explosion, or injury.
• Do not install, remove, or re-install the unit by yourself (customer).
- There is risk of fire, electric shock, explosion, or injury.
• Do not store or use flammable gas or combustibles near the air conditioner.
- There is risk of fire or failure of product.
• Use the correctly rated breaker or fuse.
- There is risk of fire or electric shock.
• Prepare for strong wind or earthquake and install the unit at the specified place.
- Improper installation may cause the unit to topple and result in injury.
• Do not install the product on a non-parallel or defective installation stand.
- It may cause injury, accident, or damage to the product.
• Use a vacuum pump or Inert(nitrogen) gas when doing leakage test or air purge. Do not compress air or Oxygen and do not use Flammable gases. Otherwise, it may cause fire or explosion.
- There is the risk of death, injury, fire or explosion.
• When installing and moving the air conditioner to another site, do not charge it with a different refrigerant from the refrigerant specified on the unit.
- If a different refrigerant or air is mixed with the original refrigerant, the refrigerant cycle may malfunction
and the unit may be damaged.
• Do not reconstruct to change the settings of the protection devices.
- If the pressure switch, thermal switch, or other protection device is shorted and operated forcibly, or
parts other than those specified by LGE are used, fire or explosion may result.
• Ventilate before operating air conditioner when gas leaked out.
- It may cause explosion, fire, and burn.
• Securely install the cover of control box and the panel.
- If the cover and panel are not installed securely, dust or water may enter the outdoor unit and fire or electric shock may result.
4
ENGLISH
• If the air conditioner is installed in a small room, measures must be taken to prevent the
Operation
• Do not damage or use an unspecified power cord.
• Use a dedicated outlet for this appliance.
• Be cautious that water could not enter the product.
• Do not touch the power switch with wet hands.
• When the product is soaked (flooded or submerged), contact an Authorized Service Center.
• Be cautious not to touch the sharp edges when installing.
• Take care to ensure that nobody could step on or fall onto the outdoor unit.
• Do not open the inlet grille of the product during operation. (Do not touch the electrostatic filter, if the unit
• Take care to ensure that power cable could not be pulled out or damaged during operation. There is risk
refrigerant concentration from exceeding the safety limit when the refrigerant leaks.
- Consult the dealer regarding the appropriate measures to prevent the safety limit from being exceeded. Should the refrigerant leak and cause the safety limit to be exceeded, hazards due to lack of oxygen in the room could result.
- There is risk of fire, electric shock, explosion, or injury.
- There is risk of fire or electrical shock.
- There is risk of fire, electric shock, or product damage.
- There is risk of fire, electric shock, explosion, or injury.
- There is risk of fire or electric shock.
- It may cause injury.
- This could result in personal injury and product damage.
is so equipped.)
- There is risk of physical injury, electric shock, or product failure.
of fire or electric shock.
CAUTION
!
Installation
• If anyone other than a licensed Professional installs, repairs, or alters LG Electronics Air Conditioning Products, the warranty is voided.
- All costs associated with repair are then the full responsibility of the owner.
• Always check for gas (refrigerant) leakage after installation or repair of product.
- Low refrigerant levels may cause failure of product.
• Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods.
- It may cause a problem for your neighbors.
• Keep level even when installing the product.
- To avoid vibration or water leakage.
• Do not install the unit where combustible gas may leak.
- If the gas leaks and accumulates around the unit, an explosion may result.
• Use power cables of sufficient current carrying capacity and rating.
- Cables that are too small may leak, generate heat, and cause a fire.
• Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.
- There is risk of damage or loss of property.
• Keep the unit away from children. The heat exchanger is very sharp.
- It can cause the injury, such as cutting the finger. Also the damaged fin may result in degradation of
capacity.
• When installing the unit in a hospital, communication station, or similar place, provide sufficient protection against noise.
-
The inverter equipment, private power generator, high-frequency medical equipment, or radio communication equipment may cause the air conditioner to operate erroneously, or fail to operate. On the other hand, the air conditioner may affect such equipment by creating noise that disturbs medical treatment or image broadcasting.
• Do not install the product where it is exposed to sea wind (salt spray) directly.
- It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins,
could cause product malfunction or inefficient operation.
• This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
Loading...
+ 7 hidden pages