Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly.
Ceilling Concealed Duct
Original instruction [
Representative
] LG Electronics Inc. EU Representative : LG Electronics European Shared
Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu,
Changwon-si, Gyeongsangnam-do, KOREA
For more information, Refer to the CD or LG Web site (www.lg.com).
INSTALLATION MANUAL
AIR CONDITIONER
P/NO : MFL67855507
ITALIANO
ESPAÑOL
FRANÇAIS DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
ENGLISH
2
Single A Air Conditioner Installation Manual
CONTENTS
Safety Precautions ..............................................................................................3
Installation Places ...............................................................................................7
The indoor unit installation ................................................................................8
Remote Controller Installation .........................................................................14
Optional Operation ............................................................................................16
How to Set E.S.P? .............................................................................................23
Self-diagnosis Function....................................................................................25
Dip Switch Setting .............................................................................................25
Safety Precautions
Installation Manual 3
ENGLISH
To prevent the injury of the user or other people and property damage, the following instructions must be followed.
n Be sure to read before installing the air conditioner. n Be sure to observe the cautions specified here as they include important items related to safety. n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
n The meanings of the symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Be sure not to do.
Be sure to follow the instruction.
Safety Precautions
n Installation
Always perform grounding.
• Otherwise, it may cause electrical shock.
Don’t use a power cord, a plug or a loose socket which is dam­aged.
• Otherwise, it may cause a fire or electrical shock.
For installation of the product, always con­tact the service center or a professional instal­lation agency.
• Otherwise, it may cause a fire, electrical shock, explosion or injury.
Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.
• If the electrical part cover of the indoor unit and the service panel of the out­door unit are not at­tached securely, it could result in a fire or electric shock due to dust, water, etc.
Always install an air leakage breaker and a dedicated switching board.
• No installation may cause a fire and electri­cal shock.
Do not keep or use flammable gases or combustibles near the air conditioner.
• Otherwise, it may cause a fire or the failure of product.
4
Safety Precautions
Do not share the outlet with other appliances.
• It will cause an electric shock or a fire due to heat generation.
Do not use the dam­aged power cord.
• Otherwise, it may cause a fire or electrical shock.
Do not modify or ex­tend the power cord randomly.
• Otherwise, it may cause a fire or electrical shock.
Take care so that the power cord may not be pulled during opera­tion.
• Otherwise, it may cause a fire or electrical shock.
Unplug the unit if strange sounds, smell, or smoke comes from it.
• Otherwise, it may cause electrical shock or a fire.
Keep the flames away.
• Otherwise, it may cause a fire.
n Operation
Use caution when unpacking and installing.
• Sharp edges may cause injury.
Ensure that an installa­tion frame of the out­door unit is not damaged due to use for a long time.
• It may cause injury or an accident.
Do not disassemble or repair the product ran­domly.
• It will cause a fire or electrical shock.
Do not install the prod­uct at a place that there is concern of falling down.
• Otherwise, it may result in personal injury.
Take the power plug out if necessary, hold­ing the head of the plug and do not touch it with wet hands.
• Otherwise, it may cause a fire or electrical shock.
Do not use the power cord near the heating tools.
• Otherwise, it may cause a fire and electrical shock.
Do not open the suc­tion inlet of the in­door/outdoor unit during operation.
• Otherwise, it may electri­cal shock and failure.
Installation Manual 5
Safety Precautions
ENGLISH
Do not allow water to run into electrical parts.
• Otherwise, it may cause the failure of machine or electrical shock.
Hold the plug by the head when taking it out.
• It may cause electric shock and damage.
Never touch the metal parts of the unit when removing the filter.
• They are sharp and may cause injury.
Do not step on the in­door/outdoor unit and do not put anything on it.
• It may cause an injury through dropping of the unit or falling down.
Do not place a heavy object on the power cord.
• Otherwise, it may cause a fire or electrical shock.
When the product is submerged into water, always contact the ser­vice center.
• Otherwise, it may cause a fire or electrical shock.
Take care so that children may not step on the outdoor unit.
• Otherwise, children may be seriously injured due to falling down.
6
Safety Precautions
n Installation
Install the drain hose to ensure that drain can be securely done.
• Otherwise, it may cause water leakage.
Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neigh­bors.
• Otherwise, it may cause dispute with the neigh­bors.
Always inspect gas leakage after the instal­lation and repair of product.
• Otherwise, it may cause the failure of product.
n Operation
Avoid excessive cool­ing and perform venti­lation sometimes.
• Otherwise, it may do harm to your health.
Use a soft cloth to clean. Do not use wax, thinner, or a strong de­tergent.
• The appearance of the air conditioner may dete­riorate, change color, or develop surface flaws.
Do not use an appli­ance for special pur­poses such as preserving animals vegetables, precision machine, or art articles.
• Otherwise, it may dam­age your properties.
Do not place obstacles around the flow inlet or outlet.
• Otherwise, it may cause the failure of appliance or an accident.
Keep level parallel in installing the product.
• Otherwise, it may cause vibration or water leakage.
Installation Places
Installation Manual 7
ENGLISH
Installation Places
Indoor unit
• The place shall easily bear a load exceeding four times the indoor unit’s weight.
The place shall be able to inspect the unit as the figure.
• The place where the unit shall be leveled.
• The place shall allow easy water drainage.(Suitable dimension “H” is necessary to get a slope to drain as figure.)
The place shall easily connect with the outdoor unit.
• The place where the unit is not affected by an electrical noise.
The place where air circulation in the room will be good .
• There should not be any heat source or steam near the unit
Top view
(unit: mm)
Front view
Inspection hole
(600 x 600)
Control box
Front
1000
H
8
The indoor unit installation
The indoor unit installation
CASE 1
POSITION OF SUSPENSION BOLT
CASE 2
POSITION OF CONSOLE BOLT
(Unit:mm)
Installation of Unit
Install the unit above the ceiling correctly.
A B C D E F (G) H I J
18/24 K
932 882 355 46 450 30 87 750 163 260
30/36 K
1232 1182 355 45.5 450 30 87 830 186 298
42/48/60 K
1290 1230 447 56 590 30 120 1006 294 380
Dimension
Capacity
• Apply a joint-canvas between the unit and duct to absorb unnecessary vibration.
• Apply a filter Accessory at air return hole.
• Install the unit leaning to a drainage hole side as a figure for easy water drainage.
• A place where the unit will be leveled and that can support the weight of the unit.
• A place where the unit can withstand its vibration.
• A place where service can be easily performed.
I
J
Joint canvas Main duct
filter
body
Drainage hole
A B
EF
CD
(G)
H
Air Intake Port
Intake Duct
Canvas Duct
Ceiling Board
Indoor Unit
Ceiling Board
Inspection Port
M10 Nut M10 SP. washer M10 washer
M10 washer M10 SP. washer M10 Nut
Discharge Flexible Duct
Air Discharge Port
X 4 X 4 X 4
X 4 X 4 X 4
Ceiling
(Local supply)
(Local supply)
The indoor unit installation
Installation Manual 9
ENGLISH
CAUTION:
Tighten the nut and bolt
top revent unit falling.
• Select and mark the position for fixing bolts.
• Drill the hole for set anchor on the face of ceiling.
• Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the ceiling.
• Mount the suspension bolts to the set anchor firmly.
• Secure the installation plates onto the suspension bolts (adjust level roughly) using nuts, washers and spring washers.
• Local supply
Set anchorPlate washer - M10Spring washer - M10Nut - W3/8 or M10Suspension bolt - W3/8 or M10
Old building New building
1 Set anchor 2 Plate washer 3 Spring washer 4 Nut
5 Suspension bolts
Loading...
+ 18 hidden pages