LG PRCTSL1 INSTALLATION INSTRUCTIONS

Page 1
LG LGMV 4.0
Installation Manual
LG
Model : PRCTSL1
IMPORTANT
• Please read this Installation Manual carefully and thoroughly before installing and operating your room air conditioner.
• Please retain this Installation Manual for future reference after reading it thoroughly.
Visit us at : http://www.lgservice.com
Page 2
2 LGMV 4.0
LGMV 4.0
TABLE OF CONTENTS
LGMV 4.0 Overview
............................................................................
3
Parts
....................................................................................................
4
Programs in CD
...................................................................................
4
Installation
...........................................................................................
5
1. Hard Lock Program Installation ..............................................................................5
2. Installation of Main LGMV Program........................................................................8
3. Port Set-up ............................................................................................................11
4. Setting the Initial Dialog Box.................................................................................19
5. Explanation about Integrated LGMV 4.0 display screen .....................................21
Page 3
LGMV 4.0 Overview
Installation Manual 3
LGMV 4.0 Overview
Heat Pump
Existing monitoring program only for 10 HP
10HP
Development completed
New tool 20HP
New tool 30HP
New tool 40HP
Developing
Heat
Recovery
Development completed
20HP
30HP
40HP
Developing
Necessary to develop the monitoring
program for each product
Issuing Integrated LGMV 4.0
Page 4
Parts
4 LGMV 4.0
+
LGMV 4.0 CD
(Program + Install manual)
HARD LOCK Key
Parts
Programs in CD
• Parts of LGMV
* NOTE : Recommended PC Specification to install LGMV Main program
• CPU : Over Pentium IV 1.6GHz
• Main Memory : Over 256MB
• Operating System : Windows NT/ 2000/ XP/ 2003 (include Microsoft Java VM)
• Hard Disk : More than 600MB when operating
• Web browser : Over Internet Explore 5.0
1. Check below files listed in CD
2. Description of file in CD
: LGMV 4.0 Installation Manual
: Hard Lock Program(LGMV 4.0 Security Program)
: LGMV 4.0 Main Software Installation file
Page 5
Installation
Installation Manual 5
Installation
1. Hard Lock Program Installation
(1) 2 files appear when the hdd32 folder is opened
(2) Execute hdd32.exe file. The following window pops up.
- Follow the below mentioned procedure
Select U.S.English and then click 'OK' button
Page 6
Installation
6 LGMV 4.0
Click 'Next' button
Click Next button
Page 7
Installation
Installation Manual 7
Click 'Finish' button to complete the installation of Hard Lock program
(3) Insert Hard Lock Key in PC Parallel Port
* NOTE : If you don't insert Hard Lock Key before LGMV main program execution,
below error message will appear.
Hard Lock Key
Page 8
Installation
8 LGMV 4.0
2. Installation of Main LGMV Program
(1) Select LGMV_TOTAL4.0
(2) Execute LGMV_TOTAL4.0.msi file. The following window pops up.
- Follow the below mentioned procedure
Click 'Next' button
Page 9
Installation
Installation Manual 9
Click 'Next' button
Click 'Next' button
Page 10
Installation
10 LGMV 4.0
Click 'Close' button to complete the LGMV_TOTAL4.0
Page 11
Installation
Installation Manual 11
3. Port set-up
LGMV 4.0 Program will be operated correctly when it is connected COM1
Serial port : COM1 port only
In case that there is not RS232 Serial port in your notebook, use USB port of your PC. Refer to '(2) Setting the USB port as the serial port' on page 14.
(1) Check COM1 port
PRCTFE0 : Additional purchase
To check COM1 port, follow the below Procedure
Select 'Start' -> 'System' -> 'Control Panel' then you can see and choose the 'System' icon in 'Control Panel'
System Overview In case of RS 232 Serial PORT In PC
PRCTFE0 connection should be done as the above picture and it would be connected to the main PCB connector of outdoor unit.
Page 12
Installation
12 LGMV 4.0
Select 'Hardware' in 'System Properties' window
Select 'Device manager' and then 'Device Manager' window appears.
Then select 'Ports(COM & LPT)' in 'Device manager' window
Page 13
Installation
Installation Manual 13
Select 'Communication Port', click right button of your mouse,
and choose 'Properties' as shown above
Select 'Port Settings' in 'Communication Port' window and click 'Advanced' button.
Page 14
Installation
14 LGMV 4.0
Check 'COM1' port and click 'OK' Button
(2) Setting the USB port as the serial port
* NOTE : Purchase 'USB to 232 Serial Converter' by yourself.(Local sourcing)
PRCTFE0 : Additional purchase
System Overview in case of using USB-Serial converter in PC
PRCTFE0 connection should be done as shown above and it would be connected to main PCB connector of the outdoor unit.
Page 15
Installation
Installation Manual 15
- Insert the USB-Serial converter into the USB port.
You can see the below window and setup the program. Follow the below mentioned procedure.
Click 'Next' button at 'Welcome to the Found New Hardware Wizard'.
Select 'Search for a suitable driver for my device' and then click 'Next.'
Page 16
Installation
16 LGMV 4.0
Select 'CD-ROM drive,' insert the installation CD, and then click 'Next.'
Page 17
Installation
Installation Manual 17
Select the registration information by selecting 'My computer' at the desktop and then click the
right button of the mouse.
Select the device manager from the hardware of the registration information and select 'USB to Serial Converter' at the port as shown at the below figure
Page 18
Installation
18 LGMV 4.0
Select 'USB to Serial Converter' and click right button of your mouse and choose 'Properties'.
Select 'Port Settings' in 'Communication Port' window and click 'Advanced' button.
Check 'COM1' port then click 'OK' Button
Page 19
Installation
Installation Manual 19
(2) Select 'Air conditioner' type, 'The combination of outdoor unit' , 'Refrigerant
type' then click 'OK' button
4. Setting the Initial Dialog Box
(1) The initial dialog box appears every time by clicking the short cut button of
LGMV on the desktop.
Page 20
Installation
20 LGMV 4.0
< LGMV Main monitoring >
(3) Explanation about the initial dialog box
'Air conditioner Type'
Heat Pump(OLD) : Air conditioner using the conventional jig protocol
1 Outdoor unit combination (Old Tool,New Tool, SPACE)2 Outdoor units combination (No Communication signal type)
Heat Pump(NEW) : Air conditioner using the integrated jig protocol
1 Outdoor Unit Combination (New Tool, SPACE), 3 Outdoor units combination
Heat Recovery(OLD) : Heat Recovery type Air conditioner using the convention
jig protocol
Heat Recovery(NEW) : Heat Recovery type Air conditioner using the integrated jig
protocol
'The combination of ODUs'
Select according to the combination of the Outdoor units(Master,Slave)SPACE model is separately handled
'Refrigerant Type'
Pressure reference table depends on the refrigerant type(R22, R410,R407C)
Page 21
Installation
Installation Manual 21
(4) System Graph
(2) Storage status window
(3) Important information of Outdoor unit
(5) Operating status window
(6) Outdoor unit / Error information window
(7) Indoor unit's information window
(1) Menu bar
5. Explanation about Integrated LGMV 4.0 display screen
You can see the abbreviation list, meaning of error number from help in the menu bar.
Page 22
Installation
22 LGMV 4.0
* NOTE : LGMV_TOTAL4.0 will be operated correctly when the PC COM port is set COM1
If below Error Message Pop-up the window then check the followings.
1) The serial cable is connected properly or not
2) Check the PC COM port is set to COM1 or not
(1) MENU BAR
You can change the items set at the initial dialog box to the other items at the menu bar. You can set it again.
Heat Pump
It is same as selecting the Air conditioner type at the initial dialog box and toutdoor combination .
Heat Recovery
It is same as selecting the Air conditioner type at the initial dialog box and outdoor combination .
Refrigerant
You can select the refrigerant type(R22, R410,R407C) again.
Page 23
Installation Manual 23
Installation
Cycle View Mode
It displays cycle diagram on the basis of current MultiV data
Page 24
24 LGMV 4.0
Installation
Numerical value disappears when changing Odu to Sub (inv onst)
Select either the outdoor unit and the indoor unit.
<Indoor Unit>
- Indicates red color while in heating and sky-blue color while in cooling mode.
- Indicates the room temperate and fan condition of indoor unit.
Pipe layout color of cycle changes in accordance with characteristics of each cycle when converting
to the cooling/heating
Possible to select indoor/outdoor unit using 'Select Odu' and 'Select Idu Gr' from the lower part.
Page 25
Installation Manual 25
Installation
Indoor unit Control Mode
Select IDU CONTROL from OPTION in the menu bar.
Indicates the current condition of the current indoor unit (cooling/heating and on/off)
On/Off status changes as you press each buttons.
Transmits the current changed details to indoor unit if only you press the 'Execution' button
Select the operation mode and indoor unit after control panel is ready.
If you want to change the operation mode, choose the opposite mode after confirming that control
panel is ready.
The IDU CONTROL only shows IDUs which are displayed in main of LGMV.
Page 26
26 LGMV 4.0
Installation
8 indoor units connected to the current outdoor unit are all off
8 indoor units connected to the current outdoor unit are operating in heating mode
8 indoor units connected to the current outdoor unit are partially operating in cooling mode
(5 indoor unit are on)
30 indoor units connected to the current outdoor unit are partially operating in heating mode (22 indoor unit are on)
OFF
Heating On
Cooling On
LGMV Indoor unit ON/OFF Function
Page 27
Installation Manual 27
Installation
Help
When you select the Help, you can see and select 3 functions
(1) Abbreviation : It displays the list of abbreviations used in LGMV main display window
Page 28
28 LGMV 4.0
Installation
(2) Error Number : It displays the table of error number and what they mean
Page 29
Installation Manual 29
Installation
(3) Alternativeness (Troubleshooting) : When an error occurs, if you select Alternativeness,
a window for error solution is displayed. You can select the error number to see the error details and its troubleshoot methods.
Page 30
30 LGMV 4.0
(2) Storage status window
It displays the air conditioner type, the protocol type, and the number of the units for the outdoor units selected at the initial dialog box of the menu bar.
When you save the data, it displays the total storage time, the number of the indoor units, the file saving location and the file name.
(3) Important information about Outdoor unit window
In order to recognize the important information about the outdoor unit, it displays compressor & fan Hz information, outdoor unit LEV information and over-cooling LEV information. M : Master, S1 : Slave1, S2 : Slave2, S3 : Slave3, LEV : Linear Expansion Valve, L : Left, R : Right PLS : Pulse
Installation
Information at the normal condition
Information at storing
*NOTE : This function does not support in the PRCTSM1, PRCTSL1 S/W
Page 31
Installation Manual 31
Installation
(4) System Graph window
- You can select the unit if you want to see its data in graph.
- You can select display time in the graph.
Graph displayed when selecting Indoor unit
Page 32
32 LGMV 4.0
Installation
Operating information displayed
Selection bar
(5) Operating status window
You can see the operating status and the control status of outdoor unit. You can see the operating status for Slave2/Slave3 by using the selection bar.
Page 33
Installation Manual 33
Installation
(6) Outdoor unit/Error information window
* Note : 200/220/300 data displayed for Outdoor unit information are meaningless.
You can get the simple error information when an error occurs by using the right scroll bar.
Selection bar
Page 34
34 LGMV 4.0
Installation
Automatically activated when controlling the number of indoor units
activated when it is the Heat recovery type
(7) Indoor unit/Distributor information window
Connectable Indroor unit capacities depend on Outdoor unit composition.(Max. 40 indoor unit)
Selection button Displayed information
Indoor unit group1 Indoor unit 1~16
Indoor unit group2 Indoor unit 17~ Indoor unit 32
Indoor unit group3 Indoor unit 33~ Indoor unit 40
Distributor group 1 Distributor 1~5
Distributor group 2 Distributor 6~10
Page 35
P/No.: 3828A20820H
After reading this manual, keep it in a place easily accessible to the user for future reference.
Printed in Korea
Loading...