2. Do shortage check neighboring pins of FPC* connector
3. Check soldering condition of defect pin
4. Scan the pattern connected to defect pin with Microscpoe
2/88
PCB Pattern Short
*FPC : Flat Pin Connector
LG Electronics / DND / QA Gr.
Symptom
Cause
Countermeasure
PCB
G
Red & Green pin of
left lower 4th FPC
short
Defect Point : Short on the PCB just above
connector
1. Cause : Short by solder bridge
- Can not observe with naked eye
- When connector open, pattern is
OK
Check Point
1. Check the contact status with connector(foreign material, soldering condition)
2. Replace X Board and check again.(If OK, X-Board is defected)
R
Change X-Board
3. By tracing defected line, check the contact condition of FPC and other connectors, IC output stage and PCB pattern.
4. If no problem, check the connector lead board.
3/88
LG Electronics / DND / QA Gr.
Symptom Cause
Countermeasure
Pattern Short by connector miss insert
Bottom Right 6th FPC R/B Short
Check Point
1. Check the contact status with connector(foreign material, soldering condition)
2. Replace X Board and check again.(If OK, X-Board is defected)
3. By tracing defected line, check the contact condition of FPC and other connectors, IC output stage and PCB pattern.
4. If no problem, check the connector lead board.
Re-insert the Connector
4/88
LG Electronics / DND / QA Gr.
SHORT
Symptom Cause
Foreign Material(Iron powder)
in the Connector
Gap
Countermeasure
X-Board Tape Rework
Insulation tape
ADD Electrode short at R,G,B Raster
or White Screen(Different color display)
▶ Apply silicon on the Connector lead
←Pay attention to a capillary symptom
↓
Check Point
1. Trace defected line
2. Check the condition of FPC and connector on the X-Board, IC Output stage and Electrode line.
5/88
LG Electronics / DND / QA Gr.
Symptom Cause
OPEN
1. Outbreak during heat run
2. ADD Electrode open at one color Raster
or White screen(No discharge)
Keep horizontal, or
can be defected
Interfere with mechanical
structure when Module
assembling
Cold soldering at
Connector
▶ Use Connector fixing iron plate
⇒ Keep the contact point horizontal
when interfere with mechanical parts
Countermeasure
FPC connector Rework
Check Point
1. Trace defected line and check the condition of FPC and connector on X-Board, IC Output stage and
Electrode line.
6/88
LG Electronics / DND / QA Gr.
Symptom Cause
Countermeasure
ADD Pattern
Connected minutely and open slowly as time passes
ADD open
Check Point
1. Replace X Board and check again(Still problem, change the Panel)
2. Check the connection status of Panel side.
3. Check the connection condition of connector of Panel side and the FPC at upper ACF.
→ If it is OK, check Panel pad
Replace the Panel
7/88
LG Electronics / DND / QA Gr.
CountermeasureSymptom & Cause
~
ADD Electrode open
at Green Raster
~
16pin
1,3,15,17,19pin
Resistance AResistance B
1.2Ω6.0Ω
1.0 ~1.2Ω2.2~2.4Ω
Panel Electrode
ACF
Open Electrode(16)
1. ADD pattern of
PAD siden open
2. Width : 10 um
Resistance B
FPC
Electrode
Resistance A
Check Point
1. Check the connection condition - Press the connector and reconnect
2. Check the soldering condition of Connector lead
3. Replace X Board and check again; Panel connector side or Circuit connector side
→ Board defect, in case of one line, check the output stage of Drive IC(Cold soldering/Pattern)
If problems in input stage, several lines display
Replace the Panel
* The difference of ADD open
and Short ?
ADD open : Black vertical
bar at Raster
ADD short : Different color
vertical bar at
Raster
8/88
LG Electronics / DND / QA Gr.
Symptom Cause
Control board
Countermeasure
Con 2
X-board
Solder bridge
< Raster >
Con 1
< White >
ADD short at raster screen and ADD open at
white screen appear at some area after 20
minute HeatRun.
Check Point
1. Check the 5V(Logic voltage) input to DC-DC → If it is lower than 5V, it makes similar problem
2. Check X Board(Open or Short circuit)
3. Check the connection condition(conncetion status, foreign material at connector, etc)
4. Check the drive IC at X Board(If defected, change the Board)
5. Confirm the connection of the connector
Change Control Board
9/88
LG Electronics / DND / QA Gr.
Symptom Cause
Countermeasure
Change X-BOARD
X-DRV IC
CLKLE
PCB pattern short
Check Point
Driver clock line at X Driver Board is designed to operate in A and B group
▶ Short circuit at clock line of Drive IC
▶ If problem at input stage, several lines are defected at one point
▶ Replace the X Board of defected point
10/88
R264
R258
SN74ACT541
Short
U1
LG Electronics / DND / QA Gr.
SymptomCause
<X-board>
Countermeasure
connector
▶ PCB pattern is connected minutely
→ Foreign material when photo resisting
Check Point
1. Check the connection condition of the Connector.
2. Check the cold soldering.
Electrode
Pattern
Chip
Resistors
4X16
= 64 data
1
(SN755851PJ)
64
line1
line2
line3
line4
X driver
chip
16 clock
M
o
d
u
l
e
Change
X Board
11/88
LG Electronics / DND / QA Gr.
Symptom Cause
Resistance between 186 pin of U3 and
7 pin of U300 is 62 Ω
Normal condition : 2Ω
Countermeasure
Because of foreign material in Via hole
at U300 side
Via hole
U300
DRAM
7pin PIN
Vertical bar in every 20mm
U3
ALTERA Chip
186pin PIN
Control board
Check Point
1. Measure the resistance of Via holes between U3 and U300 at Control Board and compare with
that of normal.(Normal : 2~3 Ω)
2. Resistance increases as temperature rises.
Change Control Board
12/88
LG Electronics / DND / QA Gr.
SymptomCause
- Open circuit between pin 7 of U200 and pin 7
of U7
- Resistance between two pins varies from
19 ohm ~ 45Kohm
Countermeasure
Replace Control Board
Check Point
1. Observe the symptom during Heat-Run at 45 degree.
2. Check the resistance of VIA holes of suspect ICs
13/88
LG Electronics / DND / QA Gr.
Symptom Cause
- When Power On, Fan operates but No OSD
displays
- LED(D3) of Control Board doesn’t operate
D1D3
D1D3
FPGA
FPGA
D4
D4
CONTROL BOARD
PROM(U40)
PROM(U40)
Countermeasure
1. Because Control data on PROM(U40) doesn’t download
to FPGA, it can’t generate control signal to X,Y and Z
Board.
2. Defected ALTERA.
•Replace Control Board
•Replace PROM
* For normal operation, PROM program should be
downloaded to FPGA, and each PROM has corr espondent FPGA. See left picture.
Check Point
1. Check D1, D3 & D4 on Control Board
- D1 : ON with 5V
- D3 : ON when PROM finishes program download from ALTERA chip
- D4 : ON when signal is applied
14/88
LG Electronics / DND / QA Gr.
Symptom Cause
Control Board
Touch point(Marked)
Countermeasure
Replace Controller board
No signal or at PC mode, dark red raster displays.
This is darker than normal Red signal.
Check Point
- TV VSC board
- Board connector(50 pin) contact point
- Control board of Module
▶ Neighboring Pins of U1(FPGA)
touch
15/88
LG Electronics / DND / QA Gr.
Symptoms Cause
1. CN1 on Vs Board cold soldering
2. Spark marks between CN1 and Vs Board
-> It makes them open
Countermeasure
Replace DC-DC 2 board
Soldering Direction
CN1
Vs board
Solder land
1. No Raster(ST-BY LED On)
2. Spark noise(Tik-Tik)
3. No Vs, Vsetup & Vsc
Check Point
1. Check Vs, Va with multimeter(No Vs output)
2. Separate SMPS Board and VSC Board and check all voltage output stage
3. Check FET, TR, Diode and Resistor(especially Cement Resistor)
4. Observe PCB Pattern and soldering condition with naked eyes
Soldering point
Solder
Soldering Direction
16/88
LG Electronics / DND / QA Gr.
40 ~ 42 Inch
42 Inch
42” PDP Flicker and
42” PDP Flicker and
No Raster Troubleshooting
No Raster Troubleshooting
P6
P4
Guide
Guide
cause : bad connection between
Y-Board
# 1, 2 drive board Connector pin
Rework should
be done
Y-Board
17
Y-Driver Board
LG Electronics / DND / QA Gr.
②
P 6
①
①
②
amplified
②
②
① : outside Leg
② : inside Leg
•P 6, P 4 both are the first pin, when
wiring, it should be done as picture
shown.
(bend the wire to Y-Driver B/D not
to Y-B/D . If not there can be noise)
•Don’t be confused with Pin number
•Improved since Dec,2001.
①
P 4
①
②
①
amplified
①
②
18
LG Electronics / DND / QA Gr.
②
①
①
②
②
①
Be sure not to misconnect the line.
See the picture precisely and then connect jump wire at the exact point
19
①
②
LG Electronics / DND / QA Gr.
Intermittent no-image/image error while watching
CANVAS
X
The screen is intermittently disappeared . LED is green
cause : bad connection between Y-Board and #1, 2 pin of
Y-Drive Board Connector
CANVAS
X
screen is distorted weiderly (happened 2 a day)
CANVAS
X
troubleshooting : connect bad linking between Y-Board &
Y-Drive with jump wire (all 4 parts)
see working instruction(revised since Dec,2001.
1)
20
normal
LG Electronics / DND / QA Gr.
No Power
CANVAS
X
No Power
( in ST-BY mode, but no LED)
Check the power supply & main power S/W on
CANVAS
X
normal
Check EMI board fuse (check the rated capacity )
Be sure to use rated fuse.
21
Fuse 15 A
LG Electronics / DND / QA Gr.
No Raster
CANVAS
X
when Power’s on, after 2 ~ 3 sec, it’s off
( LED changing green into red )
CHECK : remove STB and operate monitor individually.
(check STB defect or Monitor defect )
CANVAS
X
normal
When using ANALOG STB, check STB only
MN-42PZ10 only STB : RN-BA11
Remove each Board’s power supply connector and check the power is off.
When the power is not off,replace the related board.
22
LG Electronics / DND / QA Gr.
CANVAS
X
CANVAS
X
No Picture
no picture (LED’s green)
Core checkpoint : remove STB and operate monitor individually.
(check whether STB’s a defect or monitor’s one)
With monitor defect, check VSC and then Controller Board.