LG NL-7005 BN, NL-7000 AC User Manual

Vlijtstraat 40 Postbus 127 NL-7005 BN Doetinchem NL-7000 AC H.R. te Arnhem nr: 09087869 Tel: (+31) 314 376 876 E-mail: info@lagard.nl Internet: http://www.lagard.nl BTW nr: NL 8038.72.987.B01 Fax: (+31) 314 376 878
LA GARD Locks BV
Kantooradres: Postadres:
OPERATING INSTRUCTIONS LG 39E Multi User Combogard /Swingbolt
Keypad 3035, 3710, 3750 or 3750K with reading contact Lock 39E
LED
3035 3710
3750 3750K
Generally
Each pressing of a key is confirmed by a signal (an acoustic signal and a LED flash). A valid code is followed by a double signal, an invalid code by a triple signal. After an interval of more than 10-seconds, the already entered part of the code is deleted and the entire sequence has to be re-entered.
Code entering: Enter the seven-digit numeric code–or a word with 7 characters a) Operation with parallel code: a double signal is followed. (manager mode) Manager code: 1234567
b) Operation with dual codes: Six-digit numeric codes or words with six characters. (must be programmed) For opening two valid codes must be entered.
Opening: Combogard: Enter the code and (after double signal) turn the
Locking: Combogard: Turn the entry counter-clockwise unto the hold.
I M P O R T A N T Check the lock to be locked.
Wrong try penalty: After four invalid codes, the entry is blocked for about 5
The key pressing is refused with a triple signal.
Change of code: The user can change its code anytime. (always with open door) Enter the code and keep pressed the last number until second
The new code is now valid. If mistakes are made while
Manager code: 123456 and User ID# 654321
entry clockwise within 3 seconds unto the hold. The lock is open and the entry is rotated. Swingbolt: Enter the code and (after double signal) turn the handle within 3 seconds into the OPEN position.
If the lock is not opened within 3 seconds, it is automatically locked again.
The lock is automatically closed and the entry stands straight. (Check this by trying to turn the entry back again) Swingbolt: Turn the handle into the CLOSE position. The lock is automatically locked; check this by trying to turn the handle into “OPEN” position.
minutes. During this period, the lock signals at 10-second intervals. After this time penalty, the entry of every second invalid code initiates a new 5 minutes delay period.
double signal (LED is on), press the “0” and enter the new code (double signal), enter the new code once more for confirmation (double signal).
changing the code or if an interval occurs of more than 10 seconds, the old code remains valid and the entire sequence has to be re-entered. Test the new code several times by open door!
Contact of the audit trail
LG 39E Combogard EN Revise: 1 Datum: 16-02-05
1
Vlijtstraat 40 Postbus 127 NL-7005 BN Doetinchem NL-7000 AC H.R. te Arnhem nr: 09087869 Tel: (+31) 314 376 876 E-mail: info@lagard.nl Internet: http://www.lagard.nl BTW nr: NL 8038.72.987.B01 Fax: (+31) 314 376 878
LA GARD Locks BV
Kantooradres: Postadres:
Silent alarm: (must be programmed)
If feature is active AND optional alarm box or SP-box is connected.
If the last digit is chosen one higher (+1) when entering the code, the lock will open as usual (double signal), but at the same time the alarm box is activated. Example: Combination: 471147 Alarm code: 471148
Time delay for opening:
(Must be programmed)
Time delay override: (Must be programmed)
If feature is active: After entering a valid code (double signal) the delay period starts, the LED flashes red each 2-second interval. At the end of the delay period the Open window starts, the LED flashes each second and the lock beeps every 2 seconds. To open the lock, a valid code has to be entered during the Open window. If the Open window expires without the lock being opened, then the lock is secured again with the Time delay. Delete current delay time: press key “0” Extend current delay times: enter valid code. The delay period will start again.
The user ID# 9 (money carrier) can open immediately. At the operation with two codes the ID# 9 is entered as the second code.
Power supply:
When the batteries are running low, the lock will signal for about 3 seconds while being opened. The batteries then have to be changed. Use DURACELL ALKALINE batteries only! The codes are stored in the lock also without power supply.
3710, 3750 and 3750K: Battery compartment is in the bottom of the entry. 3035: Open battery box (inside door) and insert new batteries.
If the batteries have not been changed in time and the tension does not suffice to cancel the lock‘s blocking feature, a new 9V DURACELL ALKALINE battery can be pressed onto the contacts on the entry, until the code has been entered and the entry is rotated. When Time Delay is programmed, use a battery clip (on general sale). Black upper position, red lower position.
When connected to the alarm equipment through the interlock device “SP“ then the power supply is secured from this place.
Safety notice:
Change the manager code immediately
Do not use personal data (birth date) as a code
Keep the code from unauthorised use
LED and acoustic signals:
1 x short signal enter confirmation 2 x short signal valid code entered 3 x short signal wrong code, not accepted 6 x short signal remote disable, blocked by the alarm
equipment LED signal each 10sec. 1 flashing blocking time after a wrong tries LED signal each 2sec. Time delay before opening is running Alternate LED and acoustic signals Time window for opening is running
A series of triple signals, ca. 3seconds: Low battery Still possible ca. 10 openings. According to the battery capacity there may be also less signals
therefore the battery change should be made also in case of double signals
Use 9V DURACELL ALKALINE batteries only!
LG 39E Combogard EN Revise: 1 Datum: 16-02-05
2
Loading...
+ 1 hidden pages