SPECIFICATIONS for LG HERMETIC COMPRESSOR (Preliminary)
R407C
N K 1 1 4 P 1PH, 220/240V – 50Hz
Application Range
Compressor Cooling Natural Eva. Temp. Range -10℃ ~ 12℃ 14℉ ~ 54℉ Condensing Temp. 65℃ max. 149℉ max. Return Gas Temp. 35℃ max. 95℉ max. Discharge gas Temp. 115℃ max. 239℉ max. Motor Wire Temp. 130℃ max. 266℉ max.
Rated Performance
Capacity 5,850/5,950 Btu/h 1,714/1,744 Watts Motor Input 557/578 W Current 3.0/2.8 A EER 10.5/10.3 Btu/W.h 3.08/3.02 W/W
Compressor Data
Design Rolling Piston Typed Rotary Displacement 11.4 cc/rev 0.69 in Oil / Oil Charge FVC 68D / 330 cc Weight 11.4 Kg 25.1 lb
Motor Data
Motor Type 2 Pole Induction (PSC) Voltage Range 198 V to 264 V Locked Rotor Amps. 15 Amps.
3
/rev
DIS. I.D 8.06
±1.5
35
240
275
7.5
Detail of ⓐ
15.9
0.150
Φ118.5
Standard Dimensions
±3
93
Φ 50.8
2.3
Detail of ⓑ
SUC. I.D 9.7
200
45.9
10.0
0.5
245.9
0.150
120
R
±5
C
S
90
3 - Φ19.1
Electrical Components
Running Capacitor 25 ㎌ 370 VAC Overload Protector MRA 12012-12026 (Texas Instruments )
Capacity Test Conditions
Evaporating Temp. 7.2℃ 45℉ Condensing Temp. 54.4℃ 130℉ Return Gas Temp. 35.0℃ 95℉ Liquid Temp. 46.1℃ 115℉ Ambient Temp. 35.0℃ 95℉
Specifications are subject to change without notice. Normal Performance value ±5%.
Compressor Mounting Wiring Diagram
Bolt, Stud
Nut, Hexagon
Comp. Tri-plate
Grommet
Unit Base
35
19.1
O.L.P
Washer, Plain
28 mm
(1.10 inch)
Line
Running Capacitor
C.S.R mark is embossed on a Cover Terminal