LG MT06AH INSTALLATION INSTRUCTIONS

www.lg.com
INSTALLATION MANUAL
AIR CONDITIONER
P/NO : MFL67855405
Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly.
[
Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V.
Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[
Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si,
Gyeongsangnam-do, KOREA
For more information, Refer to the CD or LG Web site (www.lg.com).
CEILING CASSETTE Original instruction
ENGLISH
ITALIANO
ESPAÑOL FRANÇAIS
DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
2 Multi-Type Air Conditioner
Multi Type Air Conditioner Installation Manual
CONTENTS
Safety Precautions
..........................................................................................
3
Installation of Indoor
.......................................................................................
6
Test running
..................................................................................................
19
Optional Operation
........................................................................................
21
OUT-LINE OF INSTALLATION
1) Selection of the best location ......................6
2) Ceiling opening dimensions and hanging
bolt location(unit: mm).................................8
3) The Indoor Unit Installation .........................9
4) Remote Controller Installation ....................9
5) Wiring Connection.....................................12
ELECTRICAL WIRING..............................13
6) Connecting Pipes to the Indoor Unit .........14
PIPING CONNECTION.............................15
7) Installation of Decorative Panel.................16
8) Indoor Unit Drain Piping............................18
HEAT INSULATION...................................19
1) PRECAUTIONS IN TEST RUN.................19
CHECK THE FOLLOWING ITEMS WHEN INSTALLATION IS COMPLETE
..................19
2) Connection of power supply......................20
3) Evaluation of the performance ..................20
1) Test Run Mode..........................................21
2) Setting Address of Central Control............22
3) Thermistor ................................................23
4) Ceiling Height Selection............................24
5) Group Setting............................................25
6) Dry Contact Mode Setting.........................26
7) Celsius / Fahrenheit Switching..................27
8) Optional Function Setting..........................28
Installer Setting Code Table ..........................29
Safety Precautions
Installation Manual 3
ENGLISH
To prevent injury to the user or other people and property damage, the following instructions must be followed.
n
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
n Meanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
WARNING
Be sure not to do.
Be sure to follow the instruction.
Safety Precautions
n Installation
Do not use a defective or underrated circuit breaker. Use this appli­ance on a dedicated circuit.
• There is risk of fire or electric shock.
For electrical work, con­tact the dealer, seller, a qualified electrician, or an Authorized Service Center.
• Do not disassemble or repair the product. There is risk of fire or electric shock.
Always ground the product.
• There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
• There is risk of fire or electric shock.
Always install a dedi­cated circuit and break­er.
• Improper wiring or installation may cause fire or electric shock
Use the correctly rated breaker or fuse.
• There is risk of fire or electric shock.
4 Multi-Type Air Conditioner
Safety Precautions
Do not modify or extend the power cable.
• There is risk of fire or electric shock.
Be cautious when unpacking and installing the product.
Sharp edges could cause injury. Be especially care­ful of the case edges and the fins on the condenser and evaporator.
For installation, always contact the dealer or an Authorized Service Center.
• There is risk of fire, electric shock, explo­sion, or injury.
Do not install the prod­uct on a defective installation stand.
• It may cause injury, accident, or damage to the product.
Be sure the installation area does not deterio­rate with age.
If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
Do not let the air condi­tioner run for a long time when the humidity is very high and a door or a window is left open.
• Moisture may condense and wet or damage fur­niture.
Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge. Do not compress air or oxygen and do not use flammable gases. Otherwise, it may cause fire or explosion.
• There is risk of fire or failure of product.
n Operation
Do not store or use flammable gas or combustibles near the product.
• There is risk of fire or failure of product.
Safety Precautions
Installation Manual 5
ENGLISH
CAUTION
n Installation
Always check for gas (refrigerant) leakage after installation or repair of product.
• Low refrigerant levels may cause failure of product.
Install the drain hose to ensure that water is drained away properly.
• A bad connection may cause water leakage.
Keep level even when installing the product.
• To avoid vibration or water leakage.
Do not install the prod­uct where the noise or hot air from the outdoor unit could damage the neighborhoods.
• It may cause a problem for your neighbors.
Use two or more people to lift and transport the product.
• Avoid personal injury.
Do not install the prod­uct where it will be exposed to sea wind (salt spray) directly.
• It may cause corrosion on the product. Corrosion, particularly on the condenser and evap­orator fins, could cause product malfunction or inefficient operation.
6 Multi-Type Air Conditioner
Installation of Indoo
Installation of Indoor
1. Indoor unit
• There should not be any heat source or steam near the unit.
• There should not be any obstacles to pre­vent the air circulation.
• A place where air circulation in the room will be good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.
• The indoor unit must keep the mainte­nance space.
Selection of the best location
Unit:cm
Ceiling
Ceiling Board
Ceiling Board
30 or more
Above 250
330 or less
100
or more
50 or more
50 or more
30 or less
Floor
Unit:cm
Ceiling
Ceiling Board
Ceiling Board
20 or more
Above 250
330 or less
100
or more
50 or more
50 or more
30 or less
Floor
h Please use an annexed sheet or the corru-
gated cardboard on the bottom of packing as installation sheet.
h When using the bottom sheet, please use it
after separating the installation sheet from packing of the product floor by using a knife etc as a picture below.
Annexed sheet
Or
Packing corrugated
cardboard on the
bottom
Installation of Indoor
Installation Manual 7
ENGLISH
• Select and mark the position for fixing bolts and piping hole.
• Decide the position for fixing bolts slightly tilted to the drain direction after considering the direc­tion of drain hose.
• Drill the hole for anchor bolt on the wall.
CAUTION:
This air-conditioner uses a drain pump.
• Horizontly install the unit using a level gauge.
During the installation, care should be taken not to damage electric wires.
Ceiling opening dimensions and hanging bolt location
• The dimensions of the paper model for installing are the same as those of the ceiling opening dimensions.
Ceiling board
Level gauge
Ceiling
1,000 (Ceiling opening)
931.6
893.4 (Hanging bolt)
330 (Hanging bolt)
860
390
60
450 (Ceiling opening)
60
Unit: mm
585~660
517
461
517
585~660
523
570
570
319
Unit: mm
875
787
684
671
875
840
840
Set screw of paper model (4 pieces)
Paper model for installation
Ceiling board
150mm
Adjust the same height
Ceiling board
Ceiling
Flat washer for M10
(accessory)
Keep the length of the bolt
from the bracket to 40mm
Open the ceiling board along the outer edge of the paper model
Flat washer for M10
(accessory)
Hanging bolt
(W3/8 or M10)
Nut (W3/8 or M10)
Nut
(W3/8 or M10) Spring washer
(M10)
Air Conditioner body
Installation of Indoor
The Indoor Unit Installation
8 Multi-Type Air Conditioner
2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in factories, etc.
3. Avoid places where inflammable gas is generated, flows in, is stored or vented.
4. Avoid places where sulfurous acid gas or corrosive gas is generated.
5. Avoid places near high frequency generators.
• Thoroughly study the following installation locations:
1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the turbo fan, the fin of the heat exchanger and the drain pump, resulting in heat exchange reduction, spraying, dispersing of water drops, drain pump malfunction, etc. In these cases, take the following actions:
• Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient
capacity so that it draws oily steam which should not flow into the suction of the air condition­er.
• Make enough distance from a cooking room to install the air conditioner in such a place
where it may not suck in oily steam.
Use the ventilation fan for smoke-collecting hood with sufficient capacity.
Cooking table
Air conditioner
Take enough distance
NOTICE
Hanging bolt
Installation Manual 9
Installation of Indoor
ENGLISH
• The following parts is option.
Hanging Bolt - W 3/8 or M10Nut - W 3/8 or M10Spring Washer - M10Plate Washer - M10
CAUTION:
Tighten the nut and bolt
to prevent unit falling.
• Drill the piping hole on the wall slightly tilted to the outdoor side using a Ø 70 hole-core drill.
*( ) TQ/TR : 31~34mm
TP : 15mm
(W3/8 or M10)
Nut
(W3/8 or M10) Spring washer
(M10)
Keep the length of the bolt
from the bracket to 40mm
Flat washer for M10
(accessory)
Flat washer for M10
(accessory) Nut (W3/8 or M10)
Ceiling board
Adjust the same height
Ceiling
Air Conditioner body
Keep the length of *( )mm between the air conditioner bottom surface and the ceiling surface
Paper model for installation
Ceiling board
Set screw of paper model (4 pieces)
Open the ceiling board along the outer edge of the paper model
90mm
Wall
Indoor Outdoor
5~7mm