LG M09AK User Manual

P/NO : MFL67641304
OWNER’S MANUAL
Please read this manual carefully before operating your set and retain it for future reference.
TYPE : WALL MOUNTED
AIR CONDITIONER
ENGLISH
ITALIANO ESPAÑOL
FRANÇAIS
DEUTSCH
ΕΛΛΗΝΙΚΆ
PORTUGUÊS
NEDERLANDS
POLSKI
MAGYAR
1,MFL67641304,영어 2016. 12. 21. 오후 3:50 페이지 1
2
TIPS FOR SAVING ENERGY
ENGLISH
TIPS FOR SAVING ENERGY
Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below:
• Do not cool excessively indoors. This may be harmful for your health and may consume more electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air con­ditioner is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
1,MFL67641304,영어 2016. 12. 21. 오후 3:50 페이지 2
IMPORTANT SAFETY INSTRUCTIONS
3
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product
WARNING
It can result in serious injury or death when the directions are ignored
CAUTION
It can result in minor injury or product damage when the directions are ignored
WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• Appliance shall be installed in accordance with national wiring regulations.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
• The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment mal­function, property damage, personal injury and/or death.
• When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts.
Installation
• Use a standard circuit breaker and fuse conforming with the rating of the air conditioner. Fail­ure to do so may result in electric shock or product failure.
• Contact an authorized service center when you install or relocate the air conditioner. Failure to do so may result in serious injury or product failure.
• Always use a power plug and socket with a ground terminal.Failure to do so may result in electric shock or product failure
• Install the panel and the cover of the control box safely. Failure to do so may result in explo­sion or fire.
• Install a dedicated electric outlet and circuit breaker before you use the air conditioner. Failure to do so may result in electric shock or product failure.
• Use a standard circuit breaker and fuse conforming with the rating of the air conditioner. Fail­ure to do so may result in electric shock or product failure.
• Do not modify or extend the power cable. If the power cable or cord has scratches or skin peeled off or deteriorated then it must be replaced. It may result in fire or electric shock.
• Be cautious when you unpack or install the air conditioner. Failure to do so may result in seri­ous injury or product failure.
• Do not install the air conditioner on an unstable surface or where there may be a danger of it falling. It may result in death, serious injury, or product failure.
• Use inflammable gas (nitrogen) to inspect leak and to purge air, using compressed air or flam­mable gas may cause fire or explosion.
!
!
!
1,MFL67641304,영어 2016. 12. 21. 오후 3:50 페이지 3
4
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
Operation
• Do not let the air conditioner run for a long time when the humidity is very high or when a door or window has been left open. Failure to do so may result in product failure.
• Make sure that the power cord is not pulled or damaged while the air conditioner is operating. Fail­ure to do so may result in fire, electric shock, or product failure.
• Do not place any objects on the power cord. It may result in electric shock or product failure.
• Do not turn on or off the air conditioner by plugging in or unplugging the power plug. It may result in fire or electric shock.
• Do not touch, operate or repair the air conditioner with wet hands. It may result in electric shock or product failure.
• Do not place a heater or other heating appliances near the power cable. It may result in fire, electric shock, or product failure.
• Do not allow water to run into the air conditioner. It may result in explosion or fire.
• Do not leave flammable substances such as gasoline, benzene and thinner near the air conditioner. It may result in explosion or fire.
• Do not use the air conditioner for an extended period of time in a small place without ventilation. Ventilate the place regularly. Failure to do so may result in explosion or fire.
• When there is a gas leak, ventilate sufficiently before using the air conditioner again. Failure to do so may result in explosion or fire.
• Unplug the power plug if there is a noise, smell or smoke coming from the air conditioner. Failure to do so may result in explosion or fire.
• Stop operating and close the window in strom or hurricane.If possible remove the product from the window before hurricane arrives
• Do not touch the electrostatic filter after opening the front grille. Failure to do so may result in elec­tric shock or product failure.
• Contact an authorized service center when the air conditioner is submerged into water due to flood­ing. Failure to do so may result in explosion or fire.
• Be cautious water could not enter the product
• Make sure to ventilate sufficiently when this air conditioner and a heating appliance such as a heater are used simultaneously. Failure to do so may result in fire, serious injury, or product failure.
• Turn the main power off and unplug the power plug when you clean or repair the air conditioner. Failure to do so may result in death, serious injury, or product failure.
• Unplug the power plug when the air conditioner is not used for an extended period of time. Failure to do so may result in product failure.
• Do not place any objects on the air conditioner. It may result in product failure.
• For inner cleaning, contact an Authorized Service Center or a dealer. Do not use harsh detergent that causes corrosion or damage on the unit. Harsh detergent may also cause failure of product, fire, or electronic shock.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
1,MFL67641304,영어 2016. 12. 21. 오후 3:50 페이지 4
IMPORTANT SAFETY INSTRUCTIONS
CAUTION
Installation
• Make sure to check if there is a refrigerant leak after you install or repair the air conditioner. Failure to do so may result in product failure.
• Install the drain hose properly for smooth drainage of condensed water. Failure to do so may result in product failure.
• Keep level even when installing the product.
• Install the air conditioner where the noise from the outdoor unit or the exhaust gas will not incon­venience the neighbors. Failure to do so may result in conflict between neighbors.
• When transporting the equipment, there should be at least 2 or more people, or a forklift. It may re­sult in serious injury.
• Do not install the air conditioner where it will be exposed to sea wind (salt spray) directly. It may re­sult in product failure.
Operation
• Do not expose people, animals or plants to the cold or hot wind from the air conditioner. It may re­sult in serious injury.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a con-
sumer air conditioner, not a precision refrigeration system. It may result in death, fire or electric shock.
• Do not block the inlet or outlet of air flow. It may result in explosion or product failure.
• Do not use strong cleaning agents or solvents when you clean the air conditioner, or spray water. Use a smooth cloth. It may result in serious injury or product failure.
• Never touch the metal parts of the air conditioner when you remove the air filter. It may result in se­rious injury or product failure.
• Do not place any objects on the air conditioner. It may result in product failure.
• Always insert the filter securely after cleaning. Clean the filter every two weeks or more often if necessary.
• Do not insert hands or other objects through the air inlet or outlet while the air conditioner is operat­ing. It may result in electric shock.
• Do not drink the water drained from the air conditioner. It may result in serious health complications.
• Use a sturdy stool or ladder when you clean, maintain or repair the air conditioner at a height. Failure to do so may result in serious injury or product failure.
• Do not mix the batteries for the remote control with other types of batteries or mix new batteries with used batteries. Failure to do so may result in product failure.
Do not recharge or disassemble the batteries. Failure to do so may result in explosion, fire or serious injury.
• Stop using the remote control if there is a battery fluid leak. If your cloth or skin is exposed to the battery fluid from a leak, wash it off with clean water. Failure to do so may result in serious injury.
• If you swallow the battery fluid from a leak, wash out the inside of your mouth thoroughly and then consult a doctor. Failure to do so may result in serious health complications.
• Do not open or close the front panel by force during the front panel moving.
• Should open front panel after lift down front panel slowly when the product is operating.
!
5
ENGLISH
1,MFL67641304,영어 2016. 12. 21. 오후 3:50 페이지 5
TABLE OF CONTENTS
2
TIPS FOR SAVING ENERGY
3 IMPORTANT SAFETY
INSTRUCTIONS
7 BEFORE USE
7 Components
7 Operation ranges
8 Health care
9 Using remote control
10 - Inserting batteries
10 - Installing remote control holder
11 BASIC FUNCTIONS
11 Cooling your room
11 Heating your room
11 Removing humidity
12 Airing your room
12 Adjusting fan speed
12 Adjusting air flow direction
12 Setting timer
12 - Setting current time
13 - Turning on air conditioner
automatically at a set time
13 - Turning off air conditioner
automatically at a set time
13 - Canceling timer setting
13 - Setting sleep mode
14 ADVANCED FUNCTIONS
14 Changing room temperature quickly
14 Indoor air purification
15 Plasma purification operation
15 Auto operation
16 Auto changeover operation
16 °C/°F Conversion
16 Energy Control mode
17 Silent mode
17 Display screen brightness
18 Operating air conditioner without the re-
mote control
19 Restarting air conditioner
automatically
20 MAINTENANCE
22 Cleaning air filter
22 Cleaning 3M Multi protection filter
23 TROUBLESHOOTING
23 Self-diagnosis function
23 Before requesting service
TABLE OF CONTENTS
6
ENGLISH
1,MFL67641304,영어 2016. 12. 21. 오후 3:50 페이지 6
BEFORE USE
Components
Outdoor unit
NOTE
!
• The number of operation lamps and their locations may vary, depending on the model of the air conditioner.
7
BEFORE USE
ENGLISH
Indoor unit
* The feature can be changed according to a type of model.
* The feature can be changed according to a type of model.
Operation ranges
The table below indicates the temperature ranges the air conditioner can be operated within.
Mode Indoor temperature outdoor temperature Cooling 18°C~32°C -10°C~48°C Heating 16°C~30°C -15°C~24°C
1,MFL67641304,영어 2016. 12. 21. 오후 3:50 페이지 7
Front Panel
3M Multi protection filter
Air Filter
Air outlet
Air deflector (vertical louver & Horizontal vane)
On/Off button Signal receiver
Operation lamp
Plasmaster Ionizer
Air inlet vents
Air outlet vents
Coolant piping Drain hose
Connection
Base plate
wire
8
BEFORE USE
ENGLISH
3M Multi protection filter
<3M Multi
protection filter>
<Plasmaster Ionizer>
1 By providing maximum space with mini-
mum material, 3M Multi protection filter is the most efficient design which creates maximum filtration space while being sta­ble and balanced in structure.
2 Common odor filter removes ordinary odors
that cause migraine and chronic fatigue.
3 The filter blocks neuraminidase and hemag-
glutinin, which is activated when the virus breaks up from host cell to proliferate.
Plasmaster Ionizer
1
Plasmaster ion particles sterilize the aerial bacteria and other harmful substances.
2 Plasmaster ion sterilize not only the air
going through the air conditioner, but all surrounding harmful substances and even odor.
Health care
1,MFL67641304,영어 2016. 12. 21. 오후 3:50 페이지 8
BEFORE USE
9
ENGLISH
Using the remote control
You can operate the air conditioner more conveniently with the remote control. You will find the buttons for the additional functions bellow the down of the display screen.
Wireless remote control
Display screen
Control panel
* Some functions may not be supported, depending on the
model.
Control
panel
Display
screen
Description
A
K
IONIZER button*: Plasmaster Ionizer sterilize the aerial bacteria and other harmful substances.
l
Sleep mode auto button*: Sets the sleep mode auto operation.
_
Temperature adjustment buttons: Ad­justs the room temperature when cool­ing and heating.
|
- On/Off button: Turns the power on/off.
g
L
Indoor fan speed button: Adjusts the fan speed.
f
AC
DBE
Operation mode selection button*: Se­lects the operation mode. Cooling operation (A) / Auto operation or auto changeover (C) / Dehumidify­ing operation (D) / Heating operation (B) / Air circulation (E)
M
Jet cooling/heating button*: Warms up or cools down the indoor temperature within a short period of time.
DE
IJ
Air flow direction button: Adjusts the air flow direction vertically or horizontally.
k
S
Temperature display button: Displays the room temperature. Also changes unit from °C to °F if pressed for 5 seconds.
mn
Timer button: Sets the current time and the start / end time.
C B
H
I
J
J
Navigation and functions button*: Ad­justs the time and sets the special functions. I Operates SILENT mode / J Oper­ates E/Control mode /
J: Auto clean
silent Mode and E/Control are not avail­able at the same time
G
-
Adjusts the brightness of the indoor unit display
p
-
Set/clear button: Sets or cancels func­tions.
r
-
Reset button: Resets the air condi­tioner settings.
1,MFL67641304,영어 2016. 12. 21. 오후 3:50 페이지 9
10
BEFORE USE
ENGLISH
Inserting batteries
Insert batteries before using the remote control. The battery type used is AAA (1.5 V).
1 Remove the battery cover.
2 Insert the new batteries and make sure
that the + and - terminals of the batteries are installed correctly.
3 Reattach the battery cover.
Installing the remote control holder
Install the holder where there is no direct sun­light to protect the remote control.
1 Choose a safe and easily-accessible place.
2 Fix the holder by fastening the 2 screws
firmly with a screwdriver or using adhered double-sided adhesive tape.
3 Slide the remote control into the holder.
Point the remote control towards the signal receiver at the bottom of the air conditioner to operate it.
NOTE
!
• If the display screen of the remote con­trol starts to fade, replace the batteries.
NOTE
!
• The remote control may operate other electronic devices if pointed towards them. Make sure to point the remote control towards the signal receiver of the air conditioner.
• For proper operation, use a soft cloth to clean the signal transmitter and receiver.
Operating method
1,MFL67641304,영어 2016. 12. 21. 오후 3:50 페이지 10
BASIC FUNCTIONS
11
ENGLISH
BASIC FUNCTIONS
Cooling your room
(Cooling operation)
1 Press | to turn on the power. 2 Press f repeatedly to select the cooling
operation.
- A is displayed on the display screen.
3 Press G or H to set the desired tempera-
ture.
- The temperature range is 18°C(64°F) ~ 30°C(86°F) .
Heating your room
(Heating operation)
1 Press | to turn on the power. 2 Press f repeatedly to select the heating
operation.
- B is displayed on the display screen.
3 Press G or H to set the desired tempera-
ture.
- The temperature range is 16°C(60°F) ~ 30°C(86°F).
Removing humidity
(Dehumidifying operation)
This mode removes excess moisture from an environment with high humidity or in the rainy season, in order to prevent mold from setting in. This mode adjusts the room temperature and the fan speed automatically to maintain the optimal level of humidity.
1 Press | to turn on the power. 2 Press f repeatedly to select the dehu-
midifying operation.
-
D is displayed on the display screen.
NOTE
!
• In this mode you cannot adjust the de­sired temperature, as it is adjusted auto­matically. Also, the desired temperature is not displayed on the display screen.
NOTE
!
• Cooling-only models do not support this function.