LG LZ-H0156BA0, LZ-H0502BA0, LZ-H0256BA0, LZ-H0506BA0, LZ-H0806BA0 Service Manual

...
LG
Ventilation System
SERVICE MANUAL
LG
CAUTION
website http://www.lgservice.com
• BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
• ONLY FOR AUTHORIZED SERVICE PERSONNEL.
MODELS: LZ-H0106BA0
LZ-H0156BA0 LZ-H0256BA0 LZ-H0506BA0 LZ-H0502BA0 LZ-H0806BA0 LZ-H0802BA0
LZ-H1006BA0 LZ-H1002BA0 LZ-H1506BA0 LZ-H1502BA0 LZ-H2006BA0 LZ-H2002BA0
2 Ventilation System
Ventilation System Service Manual
TABLE OF CONTENTS
Safety Precautions..................................................................................................3
Standards for Model ..............................................................................................6
Product Standards .................................................................................................7
Descriptions for operation and functions .........................................................14
How to disassemble ............................................................................................17
Disassemble Diagram(Deal Drawing) and SVC Parts List ...............................22
Wiring Diagram ....................................................................................................32
Control Part Detailed Drawing ............................................................................36
Descriptions for Control Circuit .........................................................................38
Troubleshooting ...................................................................................................40
Feature Dimensions Diagram ..............................................................................47
Accessaries / Option ...........................................................................................52
Safety Precautions
Service Manual 3
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
For Installation
Be sure not to do.
Be sure to follow the instruction.
For electric working(wiring work), contact Service Center or agency you purchased the product.
• If you disassemble of repair arbitrarily, it may cause fire or electric shock.
Install in a place capable of the product's weight.
• If the product is installed in a place incapable of its weight, it may cause an accident by its dropping.
Do not arbitrarily disassemble, repair, or modify the product.
• It may cause fire or electric shock.
Be sure to undertake grounding work.
• If you do not undertake grounding work, it may cause electric shock.
Use an netted inlet for external air to prevent birds from entering.
• Remove any clogs such as bird nest. It may cause an oxygen deficiency in a room.
Install the air intake where polluted air can not be directly sucked in.
• It may cause various accidents, including suffocation, due to the suction of harmful gasses(CO, etc.)
service center
solid surface
More than
1m apart
Safety Precautions
4 Ventilation System
Wire with prescribed wire and fix firmly to prevent it from being pulled out by external impact.
Improper wiring and fixing may cause fire.
Install in accordance with installation manual.
Improper installation may cause fire and electric shock.
Electric works should be undertook by an expert in accordance with installation manual and the indicated circuit diagram.
Improper use of wires and electric may cause fire and electric shock.
Be sure to install covers for inspection and control box.
If not, water and dust infiltrating into the product may cause fire and electric shock.
Be sure to install electric leakage circuit breakers(ELB) and exclusive switch(switch for electrics).
If not, it may cause fire and electric shock.
Do not keep flammable materials or volatile gas near the product.
It may cause fire and breakdown.
Be sure to keep the product out of water.
It may cause electric shock and breakdown.
Use a fuse in standardized capacity.(Use a standardized capacity fuse)
It may cause fire and electric shock.
When unpacking, keep the product from scratches and sharp materials(object).
If not, it may cause physical damage.
Keep out of inflammable.
It may cause fire.
For the flooded product, contact Service Center.
Do not use damaged electric leakage circuit breaker or switch.
It may cause fire and electric shock.
For use
cord clamp
Technical standards
for electric work
Maintenance Cover
Control Box Cover
service center
Safety Precautions
Service Manual 5
Do not touch electric leakage circuit breaker or switch with wet hands.
It may cause electric shock.
Install the product in an insulated space.
If the product is installed outside of insulating layer(surface), it may cause a dew formation inside main body, electric shock, and dropping of condensed water.
Do not install in oily place such as kitchen and factory.
It may cause breakdown due to oils stained to filter or electric heat exchanger.
Do not install in humid place such as bathroom.
It may cause electric shock and breakdown.
Switch the power off during cleaning.
It may cause fire and electric shock.
Do not connect grounding line to window frame (chassis) and tap.
It has a danger of electric shock.
Do not carry the product alone.
Otherwise, it may cause physical damage.
Do not use for special purposes and places including animals and plants, sensitive equipment, and art pieces.
Otherwise, it may cause physical damage.
Do not use strong detergent such as wax or thinner in case of cleaning, instead use soft cloth.
It ruins external appearance due to discoloration or scratches on the product.
Clean filter and heat exchanger regularly with your gloves on.
With a large quantity of dust in the product, the effect of ventilation may be reduced. (it may not well ventilated)
In case of gas leakage, open the window to change air(ventilate) before using remote controller.
It may cause explosion and fire.
For Installation
For use
solid surface
grounding line
Standards for Model
6 Ventilation System
Standards for Model
Product Type
B: duct type hidden in ceiling T: cassette type for ceiling W: for window
Electrical Rating
6 : 1Ø, 220-240V, 50Hz
Function
A : Basic L : Nano Plasma + Clean(Wall mounted) C : Plasma(Ceiling Cassette) G : Low Static Moter
Serial No.
Marking in a developed order.
Serial No.
Marking in a developed order.
Grade
S:Standard D: Deluxe
Additional Functions
B: Base Model M : possible to connect Multi V
Product Name
ZCON(Controller)
Ventilation Capacity(Ventilating Ability)
Excluding the first digit of ventilating capacity per hour 50:500CMH
Heat Exchange Mode
H: Total heat(including humidity) T: Sensible heat(temperature only)
Product classification
LZ : ventilation
LZ-H0506BA0
Product Standards
Service Manual 7
Product Standards
Item(format) Unit LZ-H0106BA0
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220-240, 50
Total heat ventilation
Super High High Low
0.32 0.3 0.28
68 60 50
100 100 70
40 35 30
78 78 80
68 68 70
58 58 60
28 26 20
Non-woven fabric filter
24
590(W) x 590(D) x 204(H)
Item(format) Unit LZ-H0156BA0
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220-240, 50
Total heat ventilation
Super High High Low
0.36 0.36 0.35
83 80 78
150 150 90
70 55 45
75 75 79
62 62 69
55 55 59
32 30 22
Non-woven fabric filter
24
590(W) x 590(D) x 204(H)
Product Standards
8 Ventilation System
Item(format) Unit LZ-H0256BA0
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220-240, 50
Total heat ventilation
Super High High Low
0.55 0.5 0.34
130 115 80
250 250 150
65 50 40
80 80 85
70 70 78
64 64 68
32 28 21
Non-woven fabric filter
27
596(W) x 640(D) x 320(H)
Item(format) Unit LZ-H0506BA0
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220-240, 50
Total heat ventilation General ventilation
Super High High Low Super High High Low
1.51 1.39 1.06 1.51 1.39 1.06
260 225 200 260 225 200
500 500 320 500 500 320
150 60 28 150 60 28
82 82 86 - - -
79 79 83 - - -
76 76 80 - - -
34 32 25 34 32 25
Non-woven fabric filter
52
988(W) x 1,014(D) x 273(H)
Product Standards
Service Manual 9
Item(format) Unit LZ-H0502BA0
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220, 60
Total heat ventilation General ventilation
Super High High Low Super High High Low
1.25 1.07 0.9 1.25 1.07 0.9
258 235 195 258 235 195
500 500 320 500 500 320
200 70 28 200 70 28
82 82 86 - - -
79 79 83 - - -
76 76 80 - - -
34 32 25 34 32 25
Non-woven fabric filter
45
988(W) x 1,014(D) x 273(H)
Item(format) Unit LZ-H0806BA0
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220-240, 50
Total heat ventilation General ventilation
Super High High Low Super High High Low
2.8 2.7 2.6 2.8 2.7 2.6
405 360 320 405 360 320
800 800 660 800 800 660
200 110 60 200 110 60
79 79 82 - - -
70 70 75 - - -
65 65 70 - - -
36 34 30 36 34 30
Non-woven fabric filter
67
1,062(W) x 1,140(D) x 365(H)
Product Standards
10 Ventilation System
Item(format) Unit LZ-H0802BA0
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220, 60
Total heat ventilation General ventilation
Extremely strong
Strong
Weak(mild)
Extremely strong
Strong
Weak(mild)
3.1 3.0 2.5 3.1 3.0 2.5
585 555 470 585 555 470
800 800 660 800 800 660
200 110 60 200 110 60
79 79 82 - - -
70 70 75 - - -
65 65 70 - - -
36 34 30 36 34 30
Non-woven fabric filter
67
1,062(W) x 1,140(D) x 365(H)
Item(format) Unit LZ-H1006BA0
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220-240, 50
Total heat ventilation General ventilation
Extremely strong
Strong
Weak(mild)
Extremely strong
Strong
Weak(mild)
3.0 2.9 2.6 2.8 2.7 2.4
560 540 470 560 540 470
1,000 1,000 800 1,000 1,000 800
160 90 50 200 110 60
75 75 78 - - -
66 66 71 - - -
61 61 66 - - -
37 35 31 37 35 31
Non-woven fabric filter
67
1,062(W) x 1.140(D) x 365(H)
Product Standards
Service Manual 11
Item(format) Unit LZ-H1002BA0
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220, 60
Total heat ventilation General ventilation
Extremely strong
Strong
Weak(mild)
Extremely strong
Strong
Weak(mild)
3.5 3.4 2.9 3.5 3.4 2.9
675 655 560 675 655 560
1,000 1,000 800 1,000 1,000 800
200 110 60 200 110 60
75 75 78 - - -
66 66 71 - - -
61 61 66 - - -
37 35 31 37 35 31
Non-woven fabric filter
67
1,062(W) x 1,140(D) x 365(H)
Item(format) Unit LZ-H1506BA0
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220-240, 50
Total heat ventilation General ventilation
Extremely strong
Strong
Weak(mild)
Extremely strong
Strong
Weak(mild)
5.6 5.4 5.2 5.6 5.4 5.2
950 925 795 950 925 795
1,500 1,500 1,200 1,500 1,500 1,200
200 110 60 200 110 60
79 79 82 - - -
70 70 75 - - -
65 65 70 - - -
39 37 33 39 37 33
Non-woven fabric filter
146
1,313(W) x 1,140(D) x 737(H)
Product Standards
12 Ventilation System
Item(format) Unit LZ-H2006BA0
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220-240, 50
Total heat ventilation General ventilation
Super High High Low Super High High Low
6.0 5.8 5.2 5.6 5.4 4.8
1,020 970 860 1,020 970 860
2,000 2,000 1,600 2,000 2,000 1,600
160 90 50 200 110 60
75 75 78 - - -
66 66 71 - - -
61 61 66 - - -
42 38 33 42 38 33
Non-woven fabric filter
146
1,313(W) x 1,140(D) x 737(H)
Item(format) Unit LZ-H1502BA0
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220, 60
Total heat ventilation General ventilation
Super High High Low Super High High Low
6.2 6.0 5.0 6.2 6.0 5.0
1,190 1,151 960 1,190 1,151 960
1,500 1,500 1,280 1,500 1,500 1,280
200 110 70 200 110 70
79 79 82 - - -
70 70 75 - - -
65 65 70 - - -
39 37 33 39 37 33
Non-woven fabric filter
146
1,313(W) x 1,140(D) x 737(H)
Product Standards
Service Manual 13
Item(format) Unit LZ-H2002BA0
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220, 60
Total heat ventilation General ventilation
Super High High Low Super High High Low
7.0 6.8 5.8 7.0 6.8 5.8
1,344 1,306 1,122 1,344 1,306 1,122
2,000 2,000 1,600 2,000 2,000 1,600
200 110 70 200 110 70
75 75 78 - - -
66 66 71 - - -
61 61 66 - - -
42 38 33 42 38 33
Non-woven fabric filter
146
1,313(W) x 1,140(D) x 737(H)
Descriptions for operation and functions
14 Ventilation System
Descriptions for operation and functions
Main Body
1
5
6
2
4
3
Models: LZ-H0106BA0 / LZ-H0156BA0
1. Blower for Air Supply
A blower for sucking outside air.
2. Control Box
3. Blower for Exhausting
A blower for draining polluted air outside.
4. Maintenance cover
5. Total Heat Exchanger
Exchanges temperature and moisture between air supply air and exhaust air.
6. Air Filter
Prevents clogging of the Total heat exchanger due to
The figure of Total heat Exchanger can be different by the Product Model.
The figure of Total heat Exchanger can be different by the Product Model.
1
5
4
6
2
3
1. Air Filter
Prevents clogging of the Total heat exchanger due to dust.
2. Total Heat Exchanger
Exchanges temperature and moisture between air supply air and exhaust air.
3. Blower for Exhausting
A blower for draining polluted air outside.
4. Control Box
5. Blower for Air Supply
A blower for sucking outside air.
6. Maintenance cover
Models: LZ-H0256BA0
Descriptions for operation and functions
Service Manual 15
1
2
3
4
5
6
7
8
Models: LZ-H0506BA0 / LZ-H0502BA0
1. Maintenance Cover
2. Air Filter
It prevents dust from clogging in Total Heat Exchanger.
3. Total Heat Exchanger
It changes temperature and humidity between Supplying Air and exhausted air.
4. Blower for Exhausting Air
It is a fan for discharging the contaminated air to outdoor.
5. Control box
6. Blower for Exhausting Air
It is a fan for inhaling exterior air into an indoor space.
7. Damper plate(board)
It converts exchanging mode between total heat ventilation and general ventilation.
8. Total Heat Exchanger holder
It is used in guiding for the installation of Total Heat Exchanger.
The form of Total Heat Exchanger varies according to models.
The form of Total Heat Exchanger varies according to models.
1
5
6
7
8
2
3
4
Models: LZ-H0806BA0 / LZ-H0802BA0 / LZ-H1002BA0 / LZ-H1006BA0
1. Maintenance Cover
2. Air Filter
It prevents dust from clogging in Total Heat Exchanger.
3. Total Heat Exchanger
It changes temperature and humidity between Supplying Air and exhausted air.
4. Blower for Exhausting Air
It is a fan for discharging the contaminated air to outdoor.
5. Control box
6. Blower for Supplying Air
It is a fan for inhaling exterior air into an indoor space.
7. Damper plate(board)
It converts exchanging mode between total heat ventilation and general ventilation.
8. Total Heat Exchanger holder
It is used in guiding for the installation of Total Heat Exchanger.
Descriptions for operation and functions
16 Ventilation System
1
2
3
4
5
6
7
8
Models: LZ-H1506BA0 / LZ-H1502BA0 / LZ-H2006BA0 / LZ-H2002BA0
(Ventilation System remote controller ZCON-BS2) remote controller is a separate purchase.
1. Maintenance Cover
2. Air Filter
It prevents dust from clogging in Total Heat Exchanger.
3. Total Heat Exchanger
It changes temperature and humidity between Supplying Air and exhausted air.
4. Blower for Exhausting Air
It is a fan for discharging the contaminated air to outdoor.
5. Control box
6. Blower for Supplying Air
It is a fan for inhaling exterior air into an indoor space.
7. Damper plate(board)
It converts exchanging mode between total heat ventilation and general ventilation.
8. Total Heat Exchanger holder
It is used in guiding for the installation of Total Heat Exchanger.
The form of Total Heat Exchanger varies according to models.
Some functions may not work depending on models. (according to models).
LCD remote controller
Program set
Room Temp
HI MED LO
Timer
On Set no. Time
Off
01 03 05 07 09 11 13 15 17 19 21 23
Operation unit
ZONE
1234
AUTO SWING
AUTO
JET
Heater Defrost
Preheat Humidify
Filter Out door
Time
OPERATION SET TEMP FAN SPEED
SUB FUNCTION
Timer
Program
Hour
Cancel
Week Holiday
Set/Clr
PLASMA
RESET
Min
1
2
5
6 7
8
9 10 11 12 13
3
4
When the cover is open,
1. Display Screen
2. Heater Button
3. Button for time setting/ canceling, and weekend
setting/date selecting/ weekend selecting
4. Play/ Stop Button
5. Delaying time Button
6. Quick ventilation Button
7. Ventilating Mode Button
8. Air flow selection Button
9. Humidification Button
10. Power-saving/filter cleaning Button
11. Plasma Button
12. Time Reset Button
How to disassemble
Service Manual 17
Models: LZ-H0106BA0 / LZ-H0156BA0
How to disassemble
In case of service, operate through inspecting tool(hole) installed on the surface of ceiling. For main part disassembly, follow the instructions below.
Control Box
Unscrew the control box cover, and disassemble.
Total Heat Exchanger, Filter
Take the Maintenance Cover off, and take them out. (in case that the Maintenance Cover is screwed up, unscrew it first.)
Be careful of sharp area when taking the Air Filter out.
Be careful not to drop the Total Heat Exchanger from
the main body when detaching.
Fan
Take the fan out after taking the Maintenance Cover off. (in case that the Maintenance Cover is screwed up, unscrew it first.)
Be careful of sharp area when taking the fan out.
control box cover
screw
screw
Maintenance Cover
Loading...
+ 37 hidden pages