LG LZ-H100GBA2 INSTALLATION INSTRUCTIONS

www.lg.com
Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly.
[
Representative] LG Electronics Inc. EU Representative : LG Electronics European
Shared Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu,
Changwon-si, Gyeongsangnam-do, KOREA
INSTALLATION MANUAL
AIR CONDITIONER
VENTILATOR
Original instruction
P/NO : MFL67855502
ITALIANO
ESPAÑOL
FRANÇAIS
DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
ENGLISH
2 Ventilator
Ventilator Installation Manual
TABLE OF CONTENTS
Safety Precautions...............3
Introduction ..........................8
Symbols used in this
Manual.................................8
Feature Dimension
Diagram...............................8
Installation ..........................13
Installation Map .................13
Installation of Main Body ...16
Connection of Duct............16
Method to Connect
Power Cord .......................18
How to connect Remote
Controller(Accessory) .......19
Name and Function of
Remote Controller .............19
Installation instruction........20
Group control.....................22
Installer Setting -How to enter
installer setting mode ........24
How to connect Central
Controller(Accessory) .......26
Trial Operation....................27
Method to Operate and Select Air Volume –Ventilation Single Operation
............................27
Method to Operate and Select Air Volume – Interlinked Operation with Ventilation
. ...28
In case of finding a problem
at a trial operation..............29
Model Designation.............30
Airborne Noise Emission ...30
• Screws
• Nuts
• Ceiling Fixing Bolt(M10~12)
• Washer
• Aluminium Tape
• Screws
• Screw Driver
• Spanner
• Cutter
• Cutter
• Screw Driver
Installation
Requirements
Required Parts Required Tools
Safety Precautions
Installation Manual 3
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed. n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
n Meanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
Be sure not to do.
Be sure to follow the instruction.
WARNING
n Installation
Do not use a defec­tive or underrated circuit breaker. Use this appliance on a dedicated circuit.
• There is risk of fire or electric shock.
For electrical work, con­tact the dealer, seller, a qualified electrician, or an Authorized Service Center.
• Do not disassemble or repair the product. There is risk of fire or electric shock.
Always ground the product.
• There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
• There is risk of fire or electric shock.
Always install a dedi­cated circuit and breaker.
• Improper wiring or installation may cause fire or electric shock
Use the correctly rated breaker or fuse.
• There is risk of fire or electric shock.
ENGLISH
Safety Precautions
4 Ventilator
For installation, always contact the dealer or an Authorized Service Center.
• There is risk of fire, electric shock, explo­sion, or injury.
Do not install the product on a defec­tive installation stand.
• It may cause injury, accident, or damage to the product.
Do not let the product run for a long time when the humidity is very high and a door or a window is left open.
• Moisture may condense and wet or damage fur­niture.
For re-installation of the installed product, always contact the deal­er or an Authorized Service Center.
• There is risk of fire, electric shock, explo­sion or injury.
Do not open the maintenance cover of the main body during operation.
• Otherwise, it may cause electrical shock.
Use the outdoor air suction hole with the net installed to ensure that birds could not come in.
• Remove estrange things like the bird’s nest. Otherwise, it may cause scarcity of indoor oxygen.
Do not modify or extend the power cable.
• There is risk of fire or electric shock.
Do not install, remove, or re-install the unit by yourself (customer).
• There is risk of fire, electric shock, explo­sion, or injury.
Be cautious when unpacking and installing the prod­uct.
• Sharp edges could cause injury.
Safety Precautions
Installation Manual 5
ENGLISH
Install the air intake where polluted air can not be directly sucked in.
• It may cause various accidents, including suf­focation, due to the suc­tion of harmful gasses(CO, etc.)
Do not install this product in a refriger­ated warehouse, heated swimming pool or other location where the tempera­ture and humidity are significantly differ­ent.
• There is risk of electrical shock, malfunctioning.
Install this product in an environment where the tempera­ture ranges from – 10°C to +45°C and the relative humidity is less than 80%. It condensation is expected to form, heat up the fresh out­side air using a duct heater etc.
Install this product in and environments where the outside air intake meets the fol­lowing conditions: temperature range is between –15°C and +40°C and the rela­tive humidity is 80% or less.
Use the designated electrical wires for the terminal board connections, and connect the wires securely so that they will not become dis­connected. (Failure to ensure proper connections may cause fire.)
When passing metal ducts through wood­en buildings clad with metal laths, wire laths or metal, these ducts must be installed in such a way that they will not make electrical con­tact with the metal laths, wire laths or metal sheets. (Power leakage can cause ignition)
6 Ventilator
Be cautious that water could not enter the product.
• There is risk of fire, electric shock, or product damage.
Turn the breaker off when clean­ing or maintaining the product.
• There is risk of electric shock.
The outside ducts must be tilted at a gradient (1/30 or more) down toward the outdoor area from the ventilator unit, and properly insu­lated. (The entry of rain water may cause power leaks, fire or damage to household property.)
Glove should be worn when doing the installation work. (There is risk of injury.)
Avoid fire equipment
• There is risk of fire.
When the product is soaked (flooded or submerged), contact an Authorized Service Center.
• There is risk of fire or eletric shock.
Don't touch a dedicat­ed circuit or breaker with wet hands.
• There is risk of electric shock.
n Operation
When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker.
• There is risk of product damage or failure, or unintended operation.
Do not store or use flammable gas or combustibles near the product.
• There is risk of fire or failure of product.
When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on.
• Do not use the tele­phone or turn switches on or off. There is risk of explo­sion or fire
Safety Precautions
Installation Manual 7
ENGLISH
Don't connect the ground wire to the window frame or water cock.
• There is risk of electric shock.
Do not install the product at a smoky and oily place like kitchen or factory.
• Otherwise. oil may adhere to the filter or heating exchanger and cause trouble.
Install the product in an insulated space from outdoor air.
In case of installing the prod­uct outside of the insulated layer, dewing occurs inside of the main body in winter.And it causes electrical shock or falling of condensed water.
n Installation
CAUTION
Keep level even when installing the product.
• To avoid vibration or water leakage.
Use two or more peo­ple to lift and trans­port the product.
• Avoid personal injury.
Do not install the prod­uct where it will be exposed to sea wind (salt spray) directly.
It may cause corrosion on the product. Corrosion, par­ticularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.
Use a soft cloth to clean. Do not use harsh detergents, wax or thinner, etc.
• Otherwise, color or sur­face of the oroduct mav deteriorate.
Clean the filter and the heat exchanger regu­larly and use the gloves for cleaning.
Adhering to a mass of dust may cause the dete­rioration of air volume.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer ventilator, not a precision refrigeration system.
• There is risk of damage or loss of property.
n Operation
Do not block the inlet or outlet of air flow.
• It may cause product failure.
Do not step on or put anyting on the product.
• There is risk of personal injury and failure of product.
Safety Precautions
Introduction
8 Ventilator
A J
G
H
K L
B
E
C
F
D
Suspension Fixture
Blower for Supply Air
Blower for Exhaust
(Exhaust Air) (Supply Air)
(Return Air)
(Outdoor Air)
Air
SA
RA
EA
OA
Feature Dimension Diagram
Model
605 570 185 525 603 40 100 97 184 90 394 100 22
A B C D E F G H J K L kg
LZ-H015GBA2
Figure Duct Pitch Weight
Pitch of Suspension
Fixture
Duct Connection Flange
Nominal
Diameter
Model : LZ-H015GBA2
Unit : mm
h
It necessary to secure sufficient space for maintenance more than the dimensions described in the product service.
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that could cause harm to the product.
This symbol indicates special notes.
Symbols used in this Manual
Introduction
NOTICE
Introduction
Installation Manual 9
Model : LZ-H025GBA2 / LZ-H035GBA2
Model
750 680 250 850 657 711 40 150 146 155 50 502 89.2 32
A B C D E F G H J K L M kg
LZ-H025GBA2
LZ-H035GBA2
Figure Duct Pitch Weight
Pitch of Suspension
Fixture
Duct Connection Flange
Nominal
Diameter
Unit : mm
h
It necessary to secure sufficient space for maintenance more than the dimensions described in the product service.
ENGLISH
A K
Suspension Fixture
Blower for Supply Air
J
H
EA
(Exhaust Air)
Blower for Exhaust Air
Maintenance Cover
OA
(Outdoor Air)
M
L
B
E D
F
SA
(Supply Air)
RA
(Return Air)
Air Filter
Control Box
Total Heat Exchanger
G
C
Introduction
10 Ventilator
Model : LZ-H050GBA2
Model
1014 988 273 939 1025 135 200 194 252 96 590 198 44
A B C D E F G H J K L kg
LZ-H050GBA2
Figure Duct Pitch Weight
Pitch of Suspension
Fixture
Duct Connection Flange
Nominal
Diameter
Unit : mm
h
It necessary to secure sufficient space for maintenance more than the dimensions described in the product service.
EA
(Exhaust Air)
OA
(Outdoor Air)
Blower for Exhausting Air
Suspension Fixture
RA (Return Air)
SA (Supply Air )
Blower for Supplying Air
Air Filter
Control box
Maintenance Cover
Total Heat Exchanger
F