LG LZ-H035GBA4, LZ-H050GBA4, LZ-H150GBA4, LZ-H080GBA4, LZ-H200GBA4 Installation Manual

...
www.lg.com
Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly.
VENTILATOR
Original instruction
Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared
Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-
gu, Changwon-si, Gyeongsangnam-do, KOREA
For more information, Refer to the CD or LG Web site (www.lg.com).
INSTALLATION MANUAL
AIR CONDITIONER
P/NO : MFL67855526
ITALIANO
ESPAÑOL
FRANÇAIS
DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
ENGLISH
2 Ventilator
Ventilator installation manual
TABLE OF CONTENTS
• Screws
• Nuts
• Ceiling fixing bolt(M10~12)
• Washer
• Screw driver
• Spanner
Installation
requirements
Required parts Required tools
Safety precautions...............3
Introduction ..........................7
Symbols used in this
manual.................................7
Feature dimension
diagram ...............................7
Installation ..........................11
Installation map..................11
Installation of main body....13
Connection of duct ............13
Method to connect power
cord ...................................15
How to connect remote con-
troller(accessory)...............16
Group control.....................17
Installer setting -How to enter
installer setting mode ........18
Test running .......................20
Method to operate and select air volume – Interlinked oper-
ation with ventilation. .........20
Method to operate and select air volume – Ventilation single
operation ...........................21
In case of finding a problem
at a test running.................22
Airborne noise emission ....22
Available accessories........22
Safety precautions
Installation manual 3
Safety precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
Meanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
Be sure not to do.
Be sure to follow the instruction.
WARNING
Installation
Do not use a defective or underrated circuit breaker. Use this appli­ance on a dedicated circuit.
• There is risk of fire or electric shock.
For electrical work, contact the dealer, seller, a qualified elec­trician, or an author­ized service center.
• Do not disassemble or repair the product. There is risk of fire or electric shock.
Always ground the product.
• There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
• There is risk of fire or electric shock.
Always install a dedi­cated circuit and breaker.
• Improper wiring or instal­lation may cause fire or electric shock
Use the correctly rated breaker or fuse.
• There is risk of fire or electric shock.
ENGLISH
Safety precautions
4 Ventilator
Do not modify or extend the power cable.
• There is risk of fire or electric shock.
Do not install, remove, or re-install the unit by yourself (customer).
• There is risk of fire, elec­tric shock, explosion, or injury.
Be cautious when unpacking and installing the product.
• Sharp edges could cause injury.
For installation, always contact the dealer or an author­ized service center.
• There is risk of fire, elec­tric shock, explosion, or injury.
Do not install the prod­uct on a defective installation stand.
• It may cause injury, acci­dent, or damage to the product.
Do not let the product run for a long time when the humidity is very high and a door or a window is left open.
• Moisture may condense and wet or damage furni­ture.
For re-installation of the installed product, always contact the dealer or an author­ized service center.
• There is risk of fire, elec­tric shock, explosion or injury.
Do not open the main­tenance cover of the main body during operation.
• Otherwise, it may cause electrical shock.
Use the outdoor air suction hole with the net installed to ensure that birds could not come in.
• Remove estrange things like the bird’s nest. Otherwise, it may cause scarcity of indoor oxygen.
Install the air intake where polluted air can not be directly sucked in.
• It may cause various accidents, including suffo­cation, due to the suction of harmful gasses(CO, etc.)
Do not install this product in a refrigerat­ed warehouse, heated swimming pool or other location where the temperature and humidity are signifi­cantly different.
• There is risk of electrical shock, malfunctioning.
Install this product in an environment where the temperature ranges from –10°C to +45°C and the relative humidi­ty is less than 80%. It condensation is expected to form, heat up the fresh outside air using a duct heater etc.
Safety precautions
Installation manual 5
ENGLISH
Install this product in and environments where the outside air intake meets the fol­lowing conditions: temperature range is between –15°C and +40°C and the relative humidity is 80% or less.
Use the designated electrical wires for the terminal board con­nections, and connect the wires securely so that they will not become disconnected. (Failure to ensure proper connections may cause fire.)
When passing metal ducts through wooden buildings clad with metal laths, wire laths or metal, these ducts must be installed in such a way that they will not make electrical contact with the metal laths, wire laths or metal sheets. (Power leakage can cause ignition)
When the product is soaked (flooded or submerged), contact an authorized service center.
• There is risk of fire or eletric shock.
Don't touch a dedicat­ed circuit or breaker with wet hands.
• There is risk of electric shock.
When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker.
• There is risk of product damage or failure, or unintended operation.
When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on.
• Do not use the telephone or turn switches on or off. There is risk of explosion or fire.
Be cautious that water could not enter the product.
• There is risk of fire, elec­tric shock, or product damage.
Turn the breaker off when cleaning or maintaining the prod­uct.
• There is risk of electric shock.
Operation
The outside ducts must be tilted at a gradient (1/30 or more) down toward the outdoor area from the ventilator unit, and properly insulated. (The entry of rain water may cause power leaks, fire or damage to household property.)
Glove should be worn when doing the installation work. (There is risk of injury.)
Don't connect the ground wire to the window frame or water cock.
• There is risk of electric shock.
Do not install the prod­uct at a smoky and oily place like kitchen or factory.
• Otherwise. oil may adhere to the filter or heating exchanger and cause trouble.
Install the product in an insulated space from outdoor air.
In case of installing the product outside of the insulated layer, dewing occurs inside of the main body in winter.And it caus­es electrical shock or falling of condensed water.
Installation
CAUTION
Keep level even when installing the product.
• To avoid vibration or water leakage.
Use two or more peo­ple to lift and transport the product.
• Avoid personal injury.
Do not install the prod­uct where it will be exposed to sea wind (salt spray) directly.
• It may cause corrosion on the product. Corrosion, particularly on the con­denser and evaporator fins, could cause product malfunction or inefficient operation.
Use a soft cloth to clean. Do not use harsh detergents, wax or thinner, etc.
• Otherwise, color or sur­face of the oroduct mav deteriorate.
Clean the filter and the heat exchanger regu­larly and use the gloves for cleaning.
• Adhering to a mass of dust may cause the dete­rioration of air volume.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer venti­lator, not a precision refrigeration system.
• There is risk of damage or loss of property.
Operation
Do not block the inlet or outlet of air flow.
• It may cause product failure.
Do not step on or put anyting on the product.
• There is risk of personal injury and fail­ure of product.
Safety precautions
6 Ventilator
Introduction
Installation manual 7
ENGLISH
Feature dimension diagram
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that could cause harm to the product.
This symbol indicates special notes.
NOTICE
Blower for exhausting air
Blower for supplying air
Control box
Maintenance cover
Suspension fixture
Total heat exchanger
Air filter
F
RA (Return Air)
SA (Supply Air )
OA
(Outdoor Air)
EA
(Exhaust Air)
Model : LZ-H025GBA4 / LZ-H035GBA4
Model
1 014 988 273 939 1 025 135 200 194 252 96 590 198 44
A B C D E F G H J K L kg
LZ-H025GBA4 LZ-H035GBA4
Figure Duct pitch WeightPitch of suspension fixture Duct connection flange
Nominal
diameter
h
It necessary to secure sufficient space for maintenance more than the dimensions described in the product service.
Symbols used in this manual
Introduction
Unit : mm
Loading...