LG LZ-H015GBA2, LZ-H050GBA2, LZ-H080GBA2, LZ-H025GBA2, LZ-H035GBA2 Service Manual

...
Ventilation System Air Conditioner
SVC MANUAL(Exploded View)
MODEL : LZ-H015GBA2 LZ-H025GBA2 LZ-H035GBA2 LZ-H050GBA2
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
http://biz.lgservice.com
LZ-H080GBA2 LZ-H100GBA2 LZ-H150GBA2 LZ-H200GBA2
- 2 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Ventilation System Service Manual
TABLE OF CONTENTS
Safety Precautions..................................................................................................3
Standards for Model ..............................................................................................6
Product Standards .................................................................................................7
Descriptions for operation and functions ..........................................................11
How to disassemble ............................................................................................14
Disassembly Diagram (Deal Drawing) ................................................................18
Wiring Diagram ....................................................................................................23
Control Part Detailed Drawing ............................................................................27
Descriptions for Control Circuit .........................................................................29
Troubleshooting ...................................................................................................31
Feature Dimensions Diagram ..............................................................................38
Accessaries / Option ...........................................................................................43
Safety Precautions
- 3 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
For Installation
Be sure not to do.
Be sure to follow the instruction.
For electric working(wiring work), contact Service Center or agency you purchased the product.
• If you disassemble of repair arbitrarily, it may cause fire or electric shock.
Install in a place capable of the product's weight.
• If the product is installed in a place incapable of its weight, it may cause an accident by its dropping.
Do not arbitrarily disassemble, repair, or modify the product.
• It may cause fire or electric shock.
Be sure to undertake grounding work.
• If you do not undertake grounding work, it may cause electric shock.
Use an netted inlet for external air to prevent birds from entering.
• Remove any clogs such as bird nest. It may cause an oxygen deficiency in a room.
Install the air intake where polluted air can not be directly sucked in.
• It may cause various accidents, including suffocation, due to the suction of harmful gasses(CO, etc.)
service center
solid surface
More than
1m apart
Safety Precautions
- 4 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Wire with prescribed wire and fix firmly to prevent it from being pulled out by external impact.
• Improper wiring and fixing may cause fire.
Install in accordance with installation manual.
• Improper installation may cause fire and electric shock.
Electric works should be undertook by an expert in accordance with installation manual and the indicated circuit diagram.
• Improper use of wires and electric may cause fire and electric shock.
Be sure to install covers for inspection and control box.
• If not, water and dust infiltrating into the product may cause fire and electric shock.
Be sure to install electric leakage circuit breakers(ELB) and exclusive switch(switch for electrics).
• If not, it may cause fire and electric shock.
Do not keep flammable materials or volatile gas near the product.
• It may cause fire and breakdown.
Be sure to keep the product out of water.
• It may cause electric shock and breakdown.
Use a fuse in standardized capacity.(Use a standardized capacity fuse)
• It may cause fire and electric shock.
When unpacking, keep the product from scratches and sharp materials(object).
• If not, it may cause physical damage.
Keep out of inflammable.
• It may cause fire.
For the flooded product, contact Service Center.
Do not use damaged electric leakage circuit breaker or switch.
• It may cause fire and electric shock.
For use
cord clamp
Technical standards
for electric work
Maintenance Cover
Control Box Cover
service center
Safety Precautions
- 5 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Do not touch electric leakage circuit breaker or switch with wet hands.
• It may cause electric shock.
Install the product in an insulated space.
If the product is installed outside of insulating layer(surface), it may cause a dew formation inside main body, electric shock, and dropping of condensed water.
Do not install in oily place such as kitchen and factory.
• It may cause breakdown due to oils stained to filter or electric heat exchanger.
Do not install in humid place such as bathroom.
• It may cause electric shock and breakdown.
Switch the power off during cleaning.
• It may cause fire and electric shock.
Do not connect grounding line to window frame (chassis) and tap.
• It has a danger of electric shock.
Do not carry the product alone.
• Otherwise, it may cause physical damage.
Do not use for special purposes and places including animals and plants, sensitive equipment, and art pieces.
• Otherwise, it may cause physical damage.
Do not use strong detergent such as wax or thinner in case of cleaning, instead use soft cloth.
• It ruins external appearance due to discoloration or scratches on the product.
Clean filter and heat exchanger regularly with your gloves on.
• With a large quantity of dust in the product, the effect of ventilation may be reduced. (it may not well ventilated)
In case of gas leakage, open the window to change air(ventilate) before using remote controller.
• It may cause explosion and fire.
For Installation
For use
solid surface
grounding line
Standards for Model
- 6 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Standards for Model
Product Type
B: duct type hidden in ceiling T: cassette type for ceiling W: for window
Electrical Rating
G: 220-240 V, 50Hz, 1Ø / 220 V 60 HZ, 1Ø
Function
A : Basic L : Nano Plasma + Clean(Wall mounted) C : Plasma(Ceiling Cassette) G : Low Static Moter
Serial No.
Marking in a developed order.
Ventilation Capacity(Ventilating Ability)
Excluding the first digit of ventilating capacity per hour 50:500CMH
Heat Exchange Mode
H: Total heat(including humidity) T: Sensible heat(temperature only)
Product classification
LZ : ventilation
LZ-H050GBA2
Product Standards
- 7 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Product Standards
Item(format) Unit LZ-H015GBA2
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220 - 240, 50 - 60
Total heat ventilation
Super High High Low
0.84 0.76 0.45
100 90 55
150 150 100
130 100 50
75 75 79
62 62 69
55 55 59
32 31 22
Non-woven fabric filter
22
605(W) X 570(D) X 185(H)
Item(format) Unit LZ-H025GBA2
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220 - 240, 50 - 60
Total heat ventilation
Super High High Low
1.04 0.97 0.70
110 105 75
250 250 150
150 130 110
80 80 85
70 70 78
64 64 68
32 28 21
Non-woven fabric filter
32
750(W) X 680(D) X 250(H)
Product Standards
- 8 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Item(format) Unit LZ-H035GBA2
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220 - 240, 50 - 60
Total heat ventilation
Super High High Low
1.73 1.58 0.77
200 180 80
350 350 210
170 150 100
83 83 87
80 80 85
78 78 83
33 28 23
Non-woven fabric filter
32
750(W) X 680(D) X 250(H)
Item(format) Unit LZ-H050GBA2
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220 - 240, 50 - 60
Total heat ventilation
Super High High Low
1.92 1.58 0.79
230 220 85
500 500 320
150 100 50
75 75 79
72 72 77
70 70 75
34 32 25
Non-woven fabric filter
44
988(W) X 1014(D) X 273(H)
Product Standards
- 9 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Item(format) Unit LZ-H080GBA2
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220 - 240, 50 - 60
Total heat ventilation
Super High High Low
2.77 2.16 1.44
360 270 165
800 800 660
200 110 60
79 79 82
70 70 75
65 65 70
36 34 30
Non-woven fabric filter
60
1062(W) X 1140(D) X 365(H)
Item(format) Unit LZ-H100GBA2
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220 - 240, 50 - 60
Total heat ventilation
Super High High Low
3.41 2.91 1.76
470 385 210
1000 1000 800
160 90 50
75 75 78
66 66 71
61 61 66
37 35 31
Non-woven fabric filter
60
1062(W) X 1140(D) X 365(H)
Item(format) Unit LZ-H150GBA2
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220 - 240, 50 - 60
Total heat ventilation
Super High High Low
5.60 5.40 2.90
720 540 340
1500 1500 1200
200 110 60
79 79 82
70 70 75
65 65 70
39 37 33
Non-woven fabric filter
140
1313(W) X 1140(D) X 738(H)
Item(format) Unit LZ-H200GBA2
Power Ø,V,Hz
Ventilation Mode -
Wind velocity -
Electric current A
Electricity consumption W
Airflow m3/h
External static press Pa
Temperature efficiency %
Enthalpy efficiency
Heating %
Cooling %
Noise dB(A)
Air Filter -
Weight kg
Dimensions mm
1, 220 - 240, 50 - 60
Total heat ventilation
Super High High Low
6.80 5.90 3.60
930 770 420
2000 2000 1600
160 90 50
75 75 78
66 66 71
61 61 66
39 37 33
Non-woven fabric filter
140
1313(W) X 1140(D) X 738(H)
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
- 10 -
Product Standards
Descriptions for operation and functions
- 11 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Descriptions for operation and functions
Main Body
1
2
5 6
4
3
Models: LZ-H015GBA2
1. Blower for Air Supply
A blower for sucking outside air.
2. Control Box
3. Blower for Exhausting
A blower for draining polluted air outside.
4. Maintenance cover
5. Total Heat Exchanger
Exchanges temperature and moisture between air supply air and exhaust air.
6. Air Filter
Prevents clogging of the Total heat exchanger due to dust.
The figure of Total heat Exchanger can be different by the Product Model.
Descriptions for operation and functions
- 12 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
1
2
5 6
3
4
Models: LZ-H025GBA2 / LZ-H035GBA2
1. Blower for Air Supply
A blower for sucking outside air.
2. Control Box
3. Blower for Exhausting
A blower for draining polluted air outside.
4. Maintenance cover
5. Total Heat Exchanger
Exchanges temperature and moisture between air supply air and exhaust air.
6. Air Filter
Prevents clogging of the Total heat exchanger due to dust.
The figure of Total heat Exchanger can be different by the Product Model.
1
5
6
7
8
2
3
4
1. Maintenance Cover
2. Air Filter
It prevents dust from clogging in Total Heat Exchanger.
3. Total Heat Exchanger
It changes temperature and humidity between Supplying Air and exhausted air.
4. Blower for Exhausting Air
It is a fan for discharging the contaminated air to outdoor.
5. Control box
6. Blower for Exhausting Air
It is a fan for inhaling exterior air into an indoor space.
7. Damper plate(board)
It converts exchanging mode between total heat ventilation and general ventilation.
8. Total Heat Exchanger holder
It is used in guiding for the installation of Total Heat Exchanger.
Models: LZ-H050GBA2
The figure of Total heat Exchanger can be different by the Product Model.
Descriptions for operation and functions
- 13 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
1
5
6
7
8
2
3
4
Models: LZ-H080GBA2 / LZ-H100GBA2
1. Maintenance Cover
2. Air Filter
It prevents dust from clogging in Total Heat Exchanger.
3. Total Heat Exchanger
It changes temperature and humidity between Supplying Air and exhausted air.
4. Blower for Exhausting Air
It is a fan for discharging the contaminated air to outdoor.
5. Control box
6. Blower for Exhausting Air
It is a fan for inhaling exterior air into an indoor space.
7. Damper plate(board)
It converts exchanging mode between total heat ventilation and general ventilation.
8. Total Heat Exchanger holder
It is used in guiding for the installation of Total Heat Exchanger.
The form of Total Heat Exchanger varies according to models.
The form of Total Heat Exchanger varies according to models.
1
2
3
4
5
6
7
8
Models: LZ-H150GBA2 / LZ-H200GBA2
1. Maintenance Cover
2. Air Filter
It prevents dust from clogging in Total Heat Exchanger.
3. Total Heat Exchanger
It changes temperature and humidity between Supplying Air and exhausted air.
4. Blower for Exhausting Air
It is a fan for discharging the contaminated air to outdoor.
5. Control box
6. Blower for Supplying Air
It is a fan for inhaling exterior air into an indoor space.
7. Damper plate(board)
It converts exchanging mode between total heat ventilation and general ventilation.
8. Total Heat Exchanger holder
It is used in guiding for the installation of Total Heat Exchanger.
- 14 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
How to disassemble
Models: LZ-H015GBA2 / LZ-H025GBA2 / LZ-H035GBA2
How to disassemble
In case of service, operate through inspecting tool(hole) installed on the surface of ceiling. For main part disassembly, follow the instructions below.
Control Box
• Unscrew the control box cover, and disassemble.
Total Heat Exchanger, Filter
• Take the Maintenance Cover off, and take them out. (in case that the Maintenance Cover is screwed up, unscrew it first.)
• Be careful of sharp area when taking the Air Filter out.
• Be careful not to drop the Total Heat Exchanger from the main body when detaching.
Fan
• Take the fan out after taking the Maintenance Cover off. (in case that the Maintenance Cover is screwed up, unscrew it first.)
• Be careful of sharp area when taking the fan out.
Control box cover
Maintenance cover
Total Heat Exchanger
SA Motor
EA Motor
Loading...
+ 31 hidden pages