OWNER’S MANUAL
AIR CONDITIONER
DANSK SUOMI NORSK
Please read this manual carefully before operating your set and retain it for future reference.
TYPE : WINDOW
MODELS LW1816HR LW2416HR
P/NO : MFL69392003 |
www.lg.com |
Safety Precautions |
|
Before Operation |
7 |
Introduction |
|
Electrical Safety |
|
Installation |
|
Operating Instructions |
16 |
Maintenance and Service |
20 |
Do not store flammables like
gasoline benzene thinner etc. near the air conditioner
No correlation between fan |
Unplug the unit when not |
usage and oxygen depletion. |
using it for a long time. |
Hold the plug by the head |
When gas leaks, open the |
not the cable when taking |
window for ventilation before |
it out. |
operating the unit. |
Never touch the metal parts of the unit when removing the filter.
For inner cleaning, contact an Authorized Service Center or a dealer.
Do not use harsh detergent that causes corrosion or damage on the unit. Harsh detergent may also cause failure of product, fire, or electric shock.
Install the product so the exhaust and noise Follow installation
instructions
exactly. are not aimed directly at the neighbors.
Be considerate.
Do not use this appliance for special purposes such as cooling pets foods precision machinery or objects of art
Instead of running air conditioning constantly,open a window
for fresh air occasionally.
You will feel better.
If the liquid from the battery gets onto your skin or clothers wash it
well with clean water. Do
not use the remote if the battery has leaked.
y
If you eat the liquid from the battery,brush your teeth and see doctor.Do not use the
remote if the battery has leaked.
y
2.No correlation between fan usage and oxygen depletion.
3.
Introduction
Introduction
Symbols
Used
in
this
Manual
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that could cause harm to the air conditioner.
NOTICE This symbol indicates special notes.
Features
This appliance should be installed in accordance with the National Electric Code.
|
Vertical Air Deflector |
|
|
(Horizontal Louver) |
|
|
|
Horizontal Air Deflector |
|
|
(Vertical Louver) |
|
|
Air Discharge |
Cabinet |
Air Intake (Inlet Grille) |
|
Front Grille |
Air Filter |
Remote Controller |
|
|
|
|
|
Brace |
Condenser
Base Pan
Compressor
Electric Heater
Power Cord
Control Board
Evaporator
8 Room Air Conditioner
RESET |
TEST
USE OF EXTENSION CORDS
RISK OF FIRE could cause serious injury or death DO NOT use an extension cord with this window air conditioner
DO NOT use surge protectors or multi-outlet adapters with this window air conditioner
should be
Avoid shock hazard. This unit cannot be user-serviced. Do NOT open the tamper-resistant sealed portion.
All warranties and performance will be voided. This unit is not intended to be used as an ON/OFF switch.
|
|
|
|
|
|
Installation |
|
|
|
|
Foam strip |
Foam-PE |
|
|
|
|
|
|
(Plain-Back) |
(Adhesive-Backed) |
|
||
Left frame |
|
|
|
|
|
|
|
curtain |
|
|
|
|
Drain joint pipe |
|
|
|
|
|
|
|
|
||
Frame guide(2) |
|
|
|
|
|
|
|
Window locking |
|
|
|
|
|
|
|
bracket |
|
|
|
|
|
|
|
|
|
|
|
|
|
Right frame |
|
Sill bracket(2) |
|
|
|
|
|
curtain |
|
|
Support bracket(2) |
|
|
|
|
||
Type A (11) |
Type B (7) |
Type C (5) |
Type D (2) |
Carriage Bolt (2) |
Lock Nut |
(4) |
Phillips head screwdriver
Scissors or knife
Flat - blade screwdriver
Adjustable
Wrench
11
Installation
Window Requirements
NOTICE
All supporting parts should be secured to firm wood, masonry, or metal.
1.This unit is designed for installation in standard double hung windows with actual opening widths from 29" to 41".
The top and bottom window sashes must open sufficiently to allow a clear vertical opening of 18" from the bottom of the upper sash to the window stool.
2.The stool offset (height between the stool and sill) must be less than 1 1/4".
29 |
41 |
18 |
|
Preparation Of Chassis
Shipping screws
1. Remove 4 screws which fasten the cabinet at both sides and at the back. (Keep the screws for Iater use.)
2. |
pan |
3.
adhesive backed
Adhesive backed
4. frame guides
12 Room Air Conditioner
5. frame curtain
upper guide
frame guides.
6. 10 Type A screws.
Upper guide
Right Guide Panel
Left Guide panel
Screws
(Type A)
Frame guide
1.Open the window. Mark a line on the center of the window stool.
Loosely attach the sill bracket to the support bracket using the carriage bolt and the lock nut.
2.Attach the sill bracket to the window sill using the screws (Type B).
Carefully place the cabinet on the window stool and align the center mark on the bottom front with the center hole marked window stool.
Sill |
|
|
Bracket |
Support |
|
Carriage |
Bracket |
|
Lock nut |
||
Bolt |
Screw (Type B)
Sill bracket
3.Using the screw (Type D) and the lock nut, attach the support bracket to the cabinet track hole. Use the first track hole after the sill bracket on the outer edge of the window sill. Tighten the carriage bolt and the lock nut. Be sure the cabinet slants outward.
4.Pull the bottom window sash down behind the top retainer bar until they meet.
Do not drill a hole in the bottom pan. The unit is designed to operate with approximately 1/2" of water in bottom pan.
Cabinet
Track hole
Support
Bracket
Carriage bolt and lock nut
Top retainer bar
Machine screw (Type D) and lock nut
Outer edge of window sill
Window stool Front angle
13
Installation
NOTICE
1.Do not pull the window sash down so tightly that the movement of frame curtain is restricted. Attach the cabinet to the window stool by driving the screws (Type B) through the cabinet into window stool.
2.The cabinet should be installed with a very slight tilt downward toward the outside.
3.Pull each frame curtain fully to each window sash track, and pull the bottom window sash down behind the top retainer bar until it meets.
4.Attach each frame curtain the window sash by using screws (Type C).
Sash track
Front Angle
Screw(Type B)
5. Slide the unit into the cabinet.
For security purpose, reinstall screws
removed from cabinet at cabinet's sides. See page 13.
6.Cut the foam-strip Not adhesive backed to the proper length and insert between the
upper window sash and the lower window sash.
|
Power Cord |
Screw |
Screw (Type A) |
Foam-Strip
Not adhesive backed |
Window locking
7. bracket
Attach the Window locking bracket with a screw (Type C).
14 Room Air Conditioner
8.Before installing the front grille, pull out the vent control lever located above the unit control knobs, as shown.
9.Attach the front grille to the cabinet by inserting the tabs the grille into the slots on the front the cabinet. Push the grille in until it snaps into place.
Guide the lever carefully through the grille as you push it in.
10.Lift the inlet grille and secure it with a Type A screw through the front grille.
15