Installation

Required Parts

Requirements

Safety Precautions............................

3

Introduction........................................

8

Symbols used in this Manual..........

8

Features ...........................................

8

Installation ..........................................

9

Installation Tools...............................

9

Installation of Indoor, Outdoor

 

Unit ................................................

10

Air purging......................................

22

Test running.................................

24

Optional operation .....................

26

Installation guide at the seaside ...

29

Connecting cable

Pipes: Gas side Liquid side

Hanging Bolt

(W 3/8 or M10 length 650mm)

Insulated drain hose

Additional Drain hose (Inner Dia.............32mm)

Required Tools

Horizontal meter

Screw driver

Electric drill

Hole core drill (ø70mm)

Flaring Tools set

Torque Wrenches

Hexagonal Wrench (4mm, 5mm)

Gas-leak detector

Owner’s Manual

Installation Manual

Thermometer

2 Ceiling Cassette Air Conditioner

 

 

 

 

Safety Precautions

 

 

 

 

 

 

 

 

 

Safety Precautions

 

To prevent injury to the user

damage, the following instructions

must be followed.

 

■ Incorrect operation due

harm or damage. The seriousness

is classified by the following

 

 

 

 

This

of death or serious injury.

 

 

 

 

 

 

 

 

 

 

 

This

of injury or damage.

 

 

 

■ Meanings of symbols used

below.

not to do.

the instruction.

Installation

Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.

There is risk of fire or electric shock.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For electrical work, contact

Always ground the product.

the dealer, seller, a qualified

 

 

 

 

electrician, or an Authorized

 

 

 

 

Service Center.

 

 

 

 

• Do not disassemble or repair the

• There is risk of fire or electric

product. There is risk of fire or

shock.

electric shock.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install the panel and the cover

Always install a dedicated

Use the correctly rated breaker

of control box securely.

circuit and breaker.

or fuse.

There is risk of fire or electric shock.

Improper wiring or installation may cause fire or electric shock

There is risk of fire or electric shock.

Installation Manual 3

LG LTNH368DLE1 Installation Manual

Safety Precautions

Do not modify or extend the power cable.

Do not install, remove, or re-

Be cautious when unpacking

install the unit by yourself

and installing the product.

(customer).

 

There is risk of fire or electric shock.

There is risk of fire, electric shock, explosion, or injury.

Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator.

For installation, always contact the dealer or an Authorized Service Center.

There is risk of fire, electric shock, explosion, or injury.

Do not install the product on a defective installation stand.

It may cause injury, accident, or damage to the product.

Be sure the installation area does not deteriorate with age.

If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.

Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge. Do not compress air or Oxygen and Do not use Flammable gases. Otherwise, it may cause fire or explosion.

• There is the risk of death, injury, fire or explosion.

Operation

Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.

Moisture may condense and wet or damage furniture.

Do not plug or unplug the power supply plug during operation.

There is risk of fire or electric shock.

Take care to ensure that power cable could not be pulled out or damaged during operation.

There is risk of fire or electric shock.

Do not touch(operate) the product with wet hands.

There is risk of fire or electrical shock.

Do not place anything on the power cable.

There is risk of fire or electric shock.

Do not place a heater or other appliances near the power cable.

There is risk of fire and electric shock.

4 Ceiling Cassette Air Conditioner

Safety Precautions

Do not allow water to run into electric parts.

It may cause There is risk of fire, failure of the product, or electric

shock.

Do not store or use flammable gas or combustibles near the product.

There is risk of fire or failure of product.

Gasolin

Do not use the product in a tightly closed space for a long time.

• Oxygen deficiency could occur.

When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on.

Do not use the telephone or turn switches on or off.

There is risk of explosion or fire

Do not open the inlet grill of the product during operation.

(Do not touch the electrostatic filter, if the unit is so equipped.)

There is risk of physical injury, electric shock, or product failure.

If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect the power supply cable.

There is risk of electric shock or fire.

When the product is soaked (flooded or submerged), contact an Authorized Service Center.

There is risk of fire or electric shock.

Stop operation and close the window in storm or hurricane. If possible, remove the product from the window before the hurricane arrives.

There is risk of property damage, failure of product, or electric shock.

Be cautious that water could not enter the product.

There is risk of fire, electric shock, or product damage.

Ventilate the product from time to time when operating it together with a stove, etc.

• There is risk of fire or electric shock.

Turn the main power off when cleaning or maintaining the product.

• There is risk of electric shock.

Installation Manual 5

When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker.

There is risk of product damage or failure, or unintended operation.

Take care to ensure that nobody could step on or fall onto the outdoor unit.

This could result in personal injury and product damage.

Installation

Always check for gas (refrigerant) leakage after installation or repair of product.

Low refrigerant levels may cause failure of product.

 

 

 

 

 

 

Install the drain hose to

Keep level even when

ensure that water is drained

installing the product.

away properly.

 

• A bad connection may cause

• To avoid vibration or water

water leakage.

leakage.

90˚

Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods.

Use two or more people to lift and transport the product.

Do not install the product where it will be exposed to sea wind (salt spray) directly.

• It may cause a problem for your

• Avoid personal injury.

• It may cause corrosion on the product.

neighbors.

 

 

 

Corrosion, particularly on the condenser

 

 

 

 

 

and evaporator fins, could cause product

 

 

 

 

 

malfunction or inefficient operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation

Do not expose the skin directly to cool air for long periods of time.

(Don't sit in the draft.)

• This could harm to your health.

Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.

• There is risk of damage or loss of property.

6 Ceiling Cassette Air Conditioner

Do not block the inlet or outlet of air flow.

• It may cause product failure.

Do not step on or put anyting on the product. (outdoor units)

There is risk of personal injury and failure of product.

Do not drink the water drained from the product.

Use a soft cloth not use harsh solvents, etc.

There is risk of shock, or parts of the

Always insert the filter securely. Clean the filter every two weeks or more often if necessary.

A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.

Use a firm stool or ladder when cleaning or maintaining the product.

• It is not sanitary and could cause

• Be careful and avoid personal

serious health issues.

injury.

Do not insert hands or other objects through the air inlet or outlet while the product is operated.

There are sharp and moving parts that could cause personal injury.

Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries.

• There is risk of fire or explosion

Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.

• They may burn or explode.

If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.

The chemicals in batteries could cause burns or other health hazards.

Introduction

Introduction

SymbolsusedinthisManual

This symbol alerts you to the risk of electric shock.

This symbol alerts you to hazards that may cause harm to the air conditioner.

NOTICE This symbol indicates special notes.

Features

Heat Pump Model

Anti-bacteria

Signal Receptor

Air

Intake

Cooling Model

Air Outlet

 

 

Remote

 

Controller

 

Signal Receptor

8 Ceiling Cassette Air Conditioner

Installation

Installation

InstallationTools

Figure

Name

Figure

Name

 

Screw driver

 

Ohmmeter

Electric drill

Hexagonal wrench

Measuring tape, Knife

Ammeter

Hole core drill

Gas-leak detector

Spanner

Thermometer,

Horizontal meter

 

Torque wrench

Flaring tool set

Installation Manual 9

Installation

InstallationofIndoor,OutdoorUnit

Selection of the best location

1)Indoor unit

There should not be any heat source or steam near the unit.

There should not be any obstacles to prevent the air circulation.

A place where air circulation in the room will be good.

A place where drainage can be easily obtained.

A place where noise prevention is taken into consideration.

Do not install the unit near the door way.

Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.

The indoor unit must keep the maintenance space.

Ceiling

 

 

 

<![if ! IE]>

<![endif]>more

Ceiling Board

Ceiling Board

 

 

 

<![if ! IE]>

<![endif]>or

 

 

 

 

 

<![if ! IE]>

<![endif]>30

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>less

50 or

 

<![if ! IE]>

<![endif]>or more

 

 

50 or

<![if ! IE]>

<![endif]>30 or

more

<![if ! IE]>

<![endif]>100

<![if ! IE]>

<![endif]>250

<![if ! IE]>

<![endif]>less

more

 

 

 

 

 

<![if ! IE]>

<![endif]>Above

<![if ! IE]>

<![endif]>400 or

 

Unit:cm

 

 

 

 

 

 

 

 

 

 

Floor

 

 

2) Outdoor unit

More

 

Sunroof

• If an awning is built over the unit to prevent

 

30cm

 

direct sunlight or rain exposure, be careful that

 

 

 

 

 

heat radiation from the condenser is not

 

 

More than

restricted.

 

 

Fence

 

30cm

• There should not be any animals or plants

or

 

which could be affected by hot air discharged.

 

 

 

• Ensure the spaces indicated by arrows from

obstacles

More than 50cm

the wall, ceiling, fence or other obstacles.

 

 

 

 

More than 70cm

 

 

 

10 Ceiling Cassette Air Conditioner