OWNER’S MANUAL
Dome Camera
Please read this manual carefully before operating your set and retain it for future reference.
MODELS
LT913 Series
LT713 Series
P/NO : MFL66281601
LT913-B.CNLDLLI_MFL66281601_ENG.indd 1 |
8/6/10 3:59 PM |
2 Safety Information
1 SafetyInformation
1
Safety Information
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
This lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to
the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
FCC WARNING: This equipment may generate or use radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made.
REGULATORY INFORMATION: FCC Part 15
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
•A suitable conduit entries, knock-outs or glands shall be provided in the cable entries of this product in the end user.
•Caution: Danger of explosion if battery is incorrectly replaced. Replaced only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
•Holes in metal, through which insulated wires pass, shall have smooth well rounded surfaces or shall be provided with brushings.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
LT913-B.CNLDLLI_MFL66281601_ENG.indd 2 |
8/6/10 3:59 PM |
Safety Information
Warning: Do not install this equipment in a confined space such as a bookcase or similar unit.
Warning: Wiring methods shall be in accordance with the National Electric Code, ANSI/NFPA 70.
Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Warning: To reduce a risk of fire or electric shock, do not expose this product to rain or moisture.
Caution: This installation should be made by a qu alified service person and should conform to all local codes.
Caution: To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.
Caution: The apparatus should not be exposed to water (dripping or splashing) and no objects filled with liquids, such as vases, should be placed on the apparatus.
Caution:
This product employs a Laser System. To ensure proper use of this product, please read this owner’s manual carefully and retain it for future reference. Should the unit require maintenance, contact an authorized service center. Performing controls, adjustments, or carrying out
procedures other than those specified herein may result in hazardous radiation exposure. To prevent direct exposure to laser beam, do not try to open the enclosure. Visible laser radiation when open. DO NOT STARE INTO BEAM.
To disconnect power from mains, pull out the mains cord plug. When installing the product, ensure that the plug is easily accessible.
LG Electronics hereby declares that this/ these product(s) is/are in compliance with the essential requirements and other relevant provisions of Directive 2004/108/ EC, 2006/95/EC, and 2009/125/EC.
European representative :
LG Electronics Service Europe B.V. Veluwezoom 15, 1327
AE Almere. The Netherlands (Tel : +31-(0)36-547-8888)
Disposal of your old appliance
1.When this crossed-out wheeled bin symbol is attached to a product it means the product is covered by the European Directive 2002/96/EC.
2.All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities.
3.The correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health.
4.For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product.
EEECompliance with Directive. (for Turkey only)
3
1 SafetyInformation
LT913-B.CNLDLLI_MFL66281601_ENG.indd 3 |
8/6/10 3:59 PM |
4
1 SafetyInformation
Safety Information
IMPORTANT SAFETY INSTRUCTIONS
1.Read these instructions.
2.Keep these instructions.
3.Heed all warnings.
4.Follow all instructions.
5.Do not use this apparatus near water.
6.Clean only with dry cloth.
7.Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9.Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10.Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11.Only use attachments/accessories specified by the manufacturer.
12.Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when
moving the cart/apparatus combination to avoid injury from tip-over.
14.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Safety Precautions
•Do not attempt to disassemble the camera
To prevent electric shock, do not remove screws or covers. There are no user serviceable parts inside. Ask a qualified service personnel for servicing.
•Avoid the camera with direct sunlight
Do not aim the camera at bright objects.Whether the camera is in use or not, never face it with direct sunlight or other extremely bright objects. Otherwise blooming or smear may be caused.
•Handle the camera with care
Do not abuse the camera. Avoid striking, shaking, etc. The camera could be damaged by improper handling or storage.
•Do not use strong solvents or detergents
Use a dry cloth to the camera when it is dirty. If it is hard to remove the dirt on the camera, use a mild detergent and wipe it gently.
•Do not install this camera upside down
This camera is designed for mounting on the ceiling or wall.If you install this camera upside down, for example, mounted on the floor, it may cause malfunction.
13.Unplug this apparatus during lightning storms or when unused for long periods of time.
•Do not use the camera in such places as shown below. The lens may become cloudy due to condensation if the camera is used under the following conditions.
››Rapid temperature fluctuation by switching an air conditioner on and off.
››Rapid temperature fluctuation due to frequent door opening and closing.
››Use in an environment where eyeglasses become foggy.
››Use in a room filled with cigarette smoke or dust. If the lens becomes cloudy due to condensation,
LT913-B.CNLDLLI_MFL66281601_ENG.indd 4 |
8/6/10 3:59 PM |
Safety Information
remove the dome cover and wipe all moist surfaces with a soft cloth.
•Before operating, please check proper temperature, humidity and power source ratings.
Use the camera under conditions where temperature is from -10 °C to 50 °C and humidity is below 80 %. The input power source is AC 24 V.
•Consumables
Parts having contacts such as the lens-drive motors, cooling fan built inside the camera are subject to wear with time. About replacement and maintenance of such parts, please ask the nearest service center.
Camera Installation Location
Discuss the installation location for the camera with your retailer, and select a place that is strong enough
for the installation.
About Static Electricity Removal
Before installing the camera, touch a metal case or other metallic parts with your hand to remove static electricity from your body.
Do not install in areas subjected to high amounts of humidity or dust.
Doing so may cause internal components to damage more easily or malfunction.
Do not wire cables near power lines.
Tightening the Screws
Screws should be tightened sufficiently in accordance with the materials and structure of the installation location. After tightening the screws, visually inspect them to make sure there is no unevenness and that each screw is tight.
•Install the camera on a ceiling (concrete, etc.) at a location that is sufficiently strong to support it.
•Install the camera body on the foundation section of the building or sections having sufficient bearing strength.
Never install or use the camera in the following locations
•Do not install it in areas exposed to direct sunlight or rain.
•Do not install the camera near the air outlet of an air conditioner.
•Near a swimming pool or other areas where chemicals are used.
•Food preparation areas and other locations where there are large amounts of steam vapor and oil, in flammable atmospheres, other special environments.
•Areas where radiation, X-rays, strong electric waves, or magnetism is generated.
•At sea, in coastal areas, or in areas where corrosive gas is being generated.
•Areas outside of the allowable ambient operating temperature range.
5
1 SafetyInformation
LT913-B.CNLDLLI_MFL66281601_ENG.indd 5 |
8/6/10 3:59 PM |
6 Contents
Contents
16Connecting RS-485 device
17Connecting power source
17Protocol and baud rate settings
18Camera ID Setting
21 |
Removing the Protection Tape |
1 |
|
22 |
Mounting the camera |
|
|
22 |
Surface mount (optional) |
||
Safety Information |
23 |
Ceiling mount (optional) |
||
|
|
25 |
Wall mount (optional) |
|
4 |
IMPORTANT SAFETY INSTRUCTIONS |
27 |
Pendant mount (Optional) |
|
4 |
Safety Precautions |
4 |
|
|
|
|
|
||
2 |
|
|
Operation |
|
|
|
|
||
Preparation |
30 |
Setup Menu Overview |
||
|
|
|||
8 |
Introduction |
34 |
Menu navigation |
|
8 |
Features |
34 |
Accessing the camera setup menu |
|
9 |
Accessories |
34 |
General operation |
|
|
|
|||
10 |
Part Names and Functions |
35 |
Camera menu settings |
|
|
|
3
Installation
12 Connections
12 Precautions
12Basic Connection Overview
13Connecting Display device
13 |
ALARM input connection |
15ALARM output connections
16Connecting LKD1000 controller
35 |
Focus setting |
35Exposure settings
36White Balance setting
37Day/Night setting
373D-DNR setting
38Color setting
38 |
Sharpness setting |
38 PAN/TILT Settings
38Preset setting
39Group tour setting
40Pattern setting
LT913-B.CNLDLLI_MFL66281601_ENG.indd 6 |
8/6/10 3:59 PM |
41 |
Auto Pan setting |
41Privacy Mask setting
42Special setting
44 |
OSD Settings |
44 |
User title setting |
44 |
ZOOM MAG setting |
44FUNCTION setting
45DOME ID setting
45 LANGUAGE Setting
45 ALARM Setting
45Alarm In setting
46Alarm Out setting
46 RESET Setting
46 Information
46 Initialization
46 |
Factory reset |
5
Appendix
47 Specifications
47LT913N/P series
48LT913NI/PI series
50LT713N/P series
51LT713NI/PI series
Contents 7
1
2
3
4
5
LT913-B.CNLDLLI_MFL66281601_ENG.indd 7 |
8/6/10 3:59 PM |
8 Preparation
|
|
|
|
|
|
2 |
|
||
|
|
Preparation |
|
|
2 |
Introduction |
|||
<![if ! IE]> <![endif]>Preparation |
||||
The dome cameras are designed for installation in an |
||||
|
indoor or outdoor video surveillance system. |
|||
|
The camera incorporates the digital signal processor, pan/ |
|||
|
tilt mechanism, zoom lens and RS-485 communication |
|||
|
interface in a compact outdoor enclosure. |
Features
•High Sensitivity Support
The camera provides the high quality picture with 4.5 mm EX-view HAD CCD.
•Preset Position
Preset position is the function to register camera monitoring positions (preset positions). By using LKD1000 controller, you can register presets with position number. Maximum 128 Preset Positions are available. By entering the position numbers, you can move cameras to the preset positions. The moving speed and holding time are adjustable.
•Preset Tour
Preset Tour is the function to go through all the registered camera monitoring positions (preset positions). During the working PRESET TOUR, The FOCUS could not be operated properly under -10 °C (for LT713 series only)
•Group Tour
Maximum 9 group tours are able to compose the group of preset, pattern, auto pan that the operator can program to be linked together in a sequence.
•Pattern recording function
A routine of manual operations can be stored and reproduced repeatedly. The Pan, Tilt and Zoom controls are available for pattern recording.
NOTE
The available total time of pattern differs depending on camera’s operation. When the pattern recording is full, the pattern recording will automatically stop.
•Privacy Mask
Privacy zone feature enables users to veil unwanted zones. This setting is used for masking unwanted zones, hiding them from display on the monitor screen. Up to 8 zones can be registered.
•Auto Pan
The camera has an Auto Pan function that enables to keep surveillance on every detail occurring around the specific area, which is preset to watch in advance. The camera can pan among the maximum 8 points you will set. The moving speed and holding time are adjustable.
•Auto Flip
When the camera is operated to tilt through the 90°, it can be watched the opposite side of the locations by Auto Flip of a 180° horizontally.
•Optical Zoom
-- LT913 series: The optical zoom range is 1x to 37x. -- LT713 series: The optical zoom range is 1x to 27x.
•Digital Zoom
Digital zoom enhances the systems zoom range to 12 times beyond the optical zoom limit.
Total system zoom range is below.
-- LT913 series: 37x (1x digital zoom) to 444x (12x digital zoom)
-- LT713 series: 27x (1x digital zoom) to 324x (12x digital zoom)
•Alarm In function (4 channels)
Alarm input signals are supplied from external devices through the ALARM IN connector to activate ‘go to preset’ function.
•Alarm Out function (2 channels)
LT913-B.CNLDLLI_MFL66281601_ENG.indd 8 |
8/6/10 3:59 PM |
When alarm inputs are supplied via the alarm input connector on the camera, the camera sends output signals via the alarm output connector on the camera.
•Controls by General Controller
This camera can be controlled by RS-485. Especially the camera has an excellent cost-saving effect because it can be controlled by the general RX point of contact signal.
•Connects with the maximum 256 cameras
This camera can be utilized after being connected with maximum 256 cameras. Therefore, it is capable of performing an excellent job in the large buildings or department stores.
•Day & Night Function
This camera can be selected Color or Black & White. You can set Color in the daytime and Black & White at night due to the low illumination. (Filter Conversion type)
•DSS (Digital Slow Shutter) function
It is possible to highly sensitive surveillance because of DSS(Digital Slow Shutter) function.
•WDR (Wide Dynamic Range) function
The camera can be best condition to watch easily inside or outside in the strong back light.
•Power Supply
This camera must always be operated a AC 24 V. Certified/Listed, class 2 power supply only.
Accessories
For LT913NI/PI series
RJ-45 Adapter cable
For LT913N/P series
Camera main cable
RJ-45 adapter cable
Wrench
Preparation 9
2
<![if ! IE]><![endif]>Preparation
LT913-B.CNLDLLI_MFL66281601_ENG.indd 9 |
8/6/10 3:59 PM |
10 Preparation
2
<![if ! IE]><![endif]>Preparation
Part Names and Functions
LT913/713NI/PI series for Indoor
A
B
C
D
E
F
G
H
I
J
K
A BNC connector cover cap
BVideo output BNC connector
Supplies analog video signal (composite) to the connected device.
CData Port A (RJ-45)
RS-485 data communication and input data port for alarm (relay) signal.
DData Port B (RJ-45)
Output data port for alarm (relay) signal.
EThis port is not used.
FThis port is not used.
GPower input jack
Connects to a AC 24 V power supply using proper cables.
HThis port is not used.
ILocking screw
Tighten this screw to fixing the Ceiling Mount Assembly with camera body.
J Dome Cover open button.
KDome Cover
LT913-B.CNLDLLI_MFL66281601_ENG.indd 10 |
8/6/10 3:59 PM |
Preparation 11
LT913/713N/P series for Outdoor
A
B
C
D
E
F
A BNC connector cover cap
BVideo output BNC connector
Supplies analog video signal (composite) to the connected device.
CData Port A (RJ-45)
RS-485 data communication and input data port for alarm (relay) signal.
DData Port B (RJ-45)
Output data port for alarm (relay) signal.
EPower input jack
Connects to a AC 24 V power supply using proper cables.
FDome Cover
2
<![if ! IE]><![endif]>Preparation
LT913-B.CNLDLLI_MFL66281601_ENG.indd 11 |
8/6/10 3:59 PM |
12 Installation
3
<![if ! IE]><![endif]>Installation
3 Installation
Connections
Precautions
•The following steps of installation and connection work should be done by qualified service personnel or system installers and should conform to all local codes.
•Before you install and connect the camera, check and prepare the required peripheral devices and cables.
•Before you connect the camera, turn off all devices to be connected, such as this camera and DVR.
•Do not touch the dome cover’s window.
Basic Connection Overview
LT913/713NI/PI series (for Indoor) |
LT913/713N/P series (for outdoor) |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LT913-B.CNLDLLI_MFL66281601_ENG.indd 12 |
8/6/10 3:59 PM |
Installation 13
Connecting Display device
The video signal connection between the camera and the monitor.
Display device connection |
ALARM input connection
You can connect up to 4 alarm sensors to the camera. Each alarm sensor should be connected with Alarm IN COM. You can adjust the signal state to NO (normally open) or NC (normally closed) through the setup menu.
1.Connect the RJ-45 Adapter cable to the PORT A (RJ-45) cable of the camera.
2.Connect the alarm device to the RJ-45 Adapter cable. When connecting lines, check and connect the color lines of the each device correctly. Refer to the below tables for color line information.
CAUTION
Do not connect one alarm sensor to the several camera’s alarm input connector.
Alarm input connection |
|
|
|
|
A |
|
3 |
|
B |
|
|
|
|
<![if ! IE]> <![endif]>Installation |
|
|
C |
|
|
|
D |
Alarm devicee |
|
|
E |
|
|
|
|
|
|
|
F |
Alarm devicee |
|
|
|
|
|
|
|
Alarm devicee |
|
|
G |
|
|
|
|
Alarm devicee |
|
|
H |
|
|
A |
cable |
ORT |
|
RJ-45 Adapter cable |
Port A |
|
RJ-45 Adapter cable
No |
Description |
Color |
|
|
|
A |
RS-485 + |
White |
|
|
|
B |
RS-485 - |
Orange |
|
|
|
C |
NC |
Black |
|
|
|
D |
ALARM IN COM |
Red |
|
|
|
E |
ALARM IN 1 |
Green |
|
|
|
F |
ALARM IN 2 |
Yellow |
|
|
|
G |
ALARM IN 3 |
Blue |
|
|
|
H |
ALARM IN 4 |
Brown |
|
|
|
LT913-B.CNLDLLI_MFL66281601_ENG.indd 13 |
8/6/10 3:59 PM |
14 Installation
3
<![if ! IE]><![endif]>Installation
PORT A of the LT913/713NI/PI series
Description |
Color |
|
|
RS-485 + |
Red/White |
|
|
RS-485 - |
Black/White |
|
|
NC |
|
|
|
ALARM IN COM |
Red |
|
|
ALARM IN 1 |
White |
|
|
ALARM IN 2 |
Light Green |
|
|
ALARM IN 3 |
Yellow |
|
|
ALARM IN 4 |
Pink |
|
|
|
|
PORT A of the LT913/713N/P series |
|
|
|
Description |
Color |
|
|
RS-485 + |
Green |
|
|
RS-485 - |
Blue |
|
|
NC |
|
|
|
ALARM IN COM |
Yellow |
|
|
ALARM IN 1 |
Pink |
|
|
ALARM IN 2 |
Gray |
|
|
ALARM IN 3 |
White |
|
|
ALARM IN 4 |
Violet |
|
|
Alarm Input function
This speed dome camera has a terminal that can sense the alarm signals.
If the alarm sensor that has installed in a door, window, safe etc. sense a touch or shock, the alarm sensor send the alarm signal to the camera and the camera will observe the sensed position.
Change the observe position to a sensor that senses a touch or shock then return to the position that previously observed. (Set the Duration Time of Alarm Input function to “3 to 255”.)
Function status |
Mode |
|
|
|
|
While observe a |
Change the observe position to the |
|
alarmed position then return to the |
||
specific position. |
||
position that previously observed. |
||
|
||
|
|
|
While operating |
Stop preset touring and change the |
|
observe position to the alarmed |
||
Preset Tour |
||
position then restart the preset |
||
function. |
||
touring again. |
||
|
||
|
|
|
|
Stop auto panning and change the |
|
While operating |
observe position to the alarmed |
|
Auto Pan function. |
position then restart the auto |
|
|
panning again. |
|
|
|
|
|
Stop operating pattern function |
|
While operating |
and change the observe position |
|
to the alarmed position during the |
||
Pattern function. |
||
dwell time then restart the pattern |
||
|
||
|
function again. |
|
|
|
|
|
After Alarm has been cleared and |
|
in case of HOME |
finished the dwell time, it moves to |
|
POSITION is ON. |
the HOME POSITION and spend the |
|
|
dwell time at that position. |
|
|
|
NOTE
During the dwell time for alarm, you can not control the controller.
LT913-B.CNLDLLI_MFL66281601_ENG.indd 14 |
8/6/10 3:59 PM |
|
|
|
Installation |
|
|
|
|
|
|
ALARM output connections |
|
|
|
|
G |
ALARM OUT [NC2] |
Blue |
||
Connect the alarm device to the alarm output data port. |
|
|
|
|
H |
NC |
Brown |
||
Alarm signal output at an event occurrence. You can set the |
||||
|
|
|
||
Alarm Output to the normal open or normal close mode. |
|
|
|
1.Connect the RJ-45 Adapter cable to the PORT B (RJ-45) cable of the camera.
2.Connect the alarm device to the RJ-45 Adapter cable. When connecting lines, check and connect the color lines of the each device correctly. Refer to the below tables for color line information.
Alarm Out connection |
|
A |
Alarmdevicee |
B |
|
C |
Alarmdevice |
|
|
D |
|
E |
Alarmdevicee |
F |
|
G |
Alarmdevice |
|
|
H |
|
RJ--45AdAdaptercablecable |
PortORT B |
RJ-45 Adapter cable
No |
Description |
Color |
|
|
|
A |
ALARM OUT [NO1] |
White |
|
|
|
B |
ALARM OUT [COM1] |
Orange |
|
|
|
C |
ALARM OUT [NC1] |
Black |
|
|
|
D |
NC |
Red |
|
|
|
E |
ALARM OUT [NO2] |
Green |
|
|
|
F |
ALARM OUT [COM2] |
Yellow |
|
|
|
PORT B of the LT913/713NI/PI series
Description |
Color |
|
|
ALARM OUT [NC1] |
Blue |
|
|
ALARM OUT [COM1] |
Violet |
|
|
ALARM OUT [NO1] |
Brown |
|
|
NC |
|
|
|
ALARM OUT [NC2] |
Gray |
|
|
ALARM OUT [COM2] |
Orange |
|
|
ALARM OUT [NO2] |
Black |
|
|
NC |
|
|
|
|
|
PORT B of the LT913/713/N/P series |
|
|
|
Description |
Color |
|
|
ALARM OUT [NO1] |
White Blue |
|
|
ALARM OUT [COM1] |
Beige |
|
|
ALARM OUT [NC1] |
Black |
|
|
NC |
|
|
|
ALARM OUT [NO2] |
Brown |
|
|
ALARM OUT [COM2] |
Red |
|
|
ALARM OUT [NC2] |
Orange |
|
|
NC |
|
|
|
15
3
<![if ! IE]><![endif]>Installation
LT913-B.CNLDLLI_MFL66281601_ENG.indd 15 |
8/6/10 3:59 PM |
16
3
<![if ! IE]><![endif]>Installation
Installation
Connecting LKD1000 controller
1.Connect the RJ-45 Adapter cable to the PORT A (RJ-45) cable of the camera.
2.Connect the LKD1000 controller to the RJ-45 Adapter cable. (Refer to the manuals of the LKD1000 controller for more details.).
LKD1000 connection
TX+
TX-
E
F
G
H
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RJRJ-45-45AAdaptercable |
|
PortORTAA |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
RJ-45 Adapter cable |
|
|
|
||||
|
|
|
|
|
|||
No |
Description |
|
|
Color |
|||
|
|
|
|
|
|
|
|
A |
|
|
RS-485 + |
|
|
White |
|
|
|
|
|
|
|
|
|
B |
|
|
RS-485 - |
|
|
Orange |
|
|
|
|
|
|
|
|
|
Connecting RS-485 device
Use the cable that is described below for RS-485 site communication.
•Shielded, twisted pair cable
•Low impedance
•Wire gauge size is thicker than AWG #22 (0.33 mm2).
RS-485 connection
RS--485 device
E
F
G
H
RJRJ-45- Adapterdaptercablle PortORTAA
1.Connect the RJ-45 adapter cable to the PORT A (RJ-45) cable of the camera.
2.Connect the RS-485 device to the RJ-45 Adapter cable. When connecting lines, connect the “Orange color line” of the RJ-45 Adapter cable to “RX -” of the RS-485 unit and “White color line” of the RJ-45 Adapter cable to “RX +” of the RS-485 unit correctly.
RJ-45 Adapter cable
No |
Description |
Color |
|
|
|
A |
RS-485 + |
White |
|
|
|
B |
RS-485 - |
Orange |
|
|
|
PORT A of the LT913/713NI/PI series
Description |
Color |
|
|
RS-485 + |
Red/White |
|
|
RS-485 - |
Black/White |
|
|
|
|
PORT A of the LT913/713N/P series |
|
|
|
Description |
Color |
|
|
RS-485 + |
Green |
|
|
RS-485 - |
Blue |
|
|
LT913-B.CNLDLLI_MFL66281601_ENG.indd 16 |
8/6/10 3:59 PM |