Lg Lsn090hsv, Lsn120hsv Installation Guide

ENGLISH
LG
Air Conditioner
INSTALLATION MANUAL
LG
Type : Wall Mounted MODEL : LSN090HSV/LSU090HSV
LSN120HSV/LSU120HSV
http://www.lgservice.com
IMPORTANT
• Please read this instruction manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it thoroughly.
FRANÇAIS ESPAÑOL
2 Air Conditioner
Air Conditioner Installation Manual
CONTENTS
Safety Precautions............................4
Introduction........................................7
Symbols used in this Manual..........7
Installation ..........................................8
Installation Parts ..............................8
Installation Tools...............................8
Installation Map................................9
Select the best Location ..............10
Fixing Installation Plate .................11
Drill a Hole in the Wall...................11
Flaring Work...................................12
Connecting the Piping...................13
Connecting the Cables..................19
Checking the Drainage .................22
Forming the Piping ........................23
Air Purging .....................................24
Test Running..................................26
Installation guide at the seaside ...28
Piping Length and Elevation.........29
Some pieces of type "A" screws
Connecting cable
Installation guide map
Pipes: Gas side
Liquid side
Insulation materials
Additional drain pipe
(Outer diameter ..............15.5mm)
Some pieces of type "B" screws
Some pieces of type "C" screws
Level gauge
Screw driver
Electric drill
Hole core drill(ø70mm)
Horizontal meter
Flaring tool set
Specified torque wrenches
1.8kg.m, 4.2kg.m, 5.5kg.m,
6.6kg.m (different depending on model No.)
Spanner ........................Half union
A glass of water
Hexagonal wrench(4mm)
Gas-leak detector
Vacuum pump
Gauge manifold
Owner's manual
Thermometer
Remote controller holder
Installation
Requirements
Required Parts Required Tools
IMPORTANT! Please read this instruction sheet completely before installing the product.
This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.
CAUTION
: Improper installation, adjustment, alteration, service or maintenance can void the warranty.
The weight of the condensing unit requires caution and proper handling procedures when lifting or moving to avoid personal injury. Use care to avoid contact with sharp or pointed edges.
Safety Precautions
Always wear safety eye wear and work gloves when installing equipment.
Never assume electrical power is disconnected. Check with meter and equipment.
Keep hands out of fan areas when power is connected to equipment.
R-410A causes frostbite burns.
R-410A is toxic when burned.
NOTE TO INSTALLING DEALER: The Owners Instructions and Warranty are to be given to the owner
or prominently displayed near the indoor Furnace/Air Handler Unit.
When wiring:
Electrical shock can cause severe personal injury or death. Only a qualified, experienced electrician should attempt to wire this system.
Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.
Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these
instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.
Ground the unit following local electrical codes.
Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.
When transporting:
Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your finger.
When installing...
... in a wall: Make sure the wall is strong enough to hold the unit's weight.
It may be necessary to construct a strong wood or metal frame to provide added support.
... in a room: Properly insulate any tubing run inside a room to prevent "sweating" that can cause
dripping and water damage to wall and floors.
... in moist or uneven locatinons: Use a raised concrete pad or concrete blocks provide a solid,
level foundation for the outdoor unit. This prevents water damage and abnormal vibration.
... in an area with high winds: Securely anchor the outdoor unit down with bolts and a metal
frame. Provide a suitable air baffle.
... in a snowy area(for Heat Pump Model): Install the outdoor unit on a raised platform that is
higher than drifting snow. Provide snow vents.
When connecting refrigerant tubing
Keep all tubing runs as short as possible.
Use the flare method for connecting tubing.
Check carefully for leaks before starting the test run.
When servicing
Turn the power OFF at the main power box(mains) before opening the unit to check or repair electrical parts and wiring.
Keep your fingers and clothing away from any moving parts.
Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have
been left inside the unit being serviced.
WARNING
WARNING
Refer to local code for all wiring size.
Installation or repairs made by unqualified persons can result in hazards to you and others. Installation MUST conform with local building codes or, in the absence of local codes, with the National Electrical Code NFPA 70/ANSI C1-1993 or current edition and Canadian Electrical Code Part1 CSA C.22.1.
The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.
Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.
Wall Mounted Mini-Split System
Single Zone
INSTALLATION INSTRUCTIONS
Installation Manual 3
ENGLISH
4 Air Conditioner
Safety Precautions
To prevent the injury of the user or other people and property damage, the following instructions must be followed.
Be sure to read before installing the air conditioner.
Be sure to observe the cautions specified here as they include important items related to safety.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
The meanings of the symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Installation
Be sure not to do.
Be sure to follow the instruction.
Safety Precautions
Always perform grounding.
Otherwise, it may cause electrical shock.
Dont use a power cord, a plug or a loose socket which is damaged.
Otherwise, it may cause a fire or electrical shock.
For installation of the product, always contact the service center or a professional installation agency.
Otherwise, it may cause a fire, electrical shock, explosion or injury.
Securely attach the electrical cover to indoor and pipe cover to outdoor unit.
If the electrical part cover to indoor unit and pipe cover to outdoor unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc.
Always install an air leakage breaker and a dedicated switching board.
No installation may cause a fire and electrical shock.
Do not keep or use flammable gases or combustibles near the air conditioner.
Otherwise, it may cause a fire or the failure of product.
Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time.
It may cause injury or an accident.
Do not disassemble or repair the product randomly.
It will cause a fire or electrical shock.
Installation Manual 5
ENGLISH
Safety Precautions
Do not install the product at a place that there is concern of falling down.
Otherwise, it may result in personal injury.
Use caution when unpacking and installing.
Sharp edges may cause injury.
Take the power plug out if necessary, holding the head of the plug and do not touch it with wet hands.
Otherwise, it may cause a fire or electrical shock.
Do not use the power cord near the heating tools.
Otherwise, it may cause a fire and electrical shock.
Do not open the inlet of the indoor/outdoor unit during operation.
Otherwise, it may cause electrical shock and failure.
Do not allow water to run into electrical parts.
Otherwise, it may cause the failure of machine or electrical shock.
Hold the plug by the head when taking it out.
It may cause electric shock and damage.
Never touch the metal parts of the unit when removing the filter.
They are sharp and may cause injury.
Do not share the outlet with other appliances.
It will cause an electric shock or a fire due to heat generation.
Do not use the damaged power cord.
Otherwise, it may cause a fire or electrical shock.
Do not modify or extend the power cord randomly.
Otherwise, it may cause a fire or electrical shock.
Take care so that the power cord may not be pulled during operation.
Otherwise, it may cause a fire or electrical shock.
Unplug the unit if strange sounds, smell, or smoke comes from it.
Otherwise, it may cause electrical shock or a fire.
Keep the flames away.
Otherwise, it may cause a fire.
Do not step on the indoor/outdoor unit and do not put anything on it.
It may cause an injury through dropping of the unit or falling down.
Do not place a heavy object on the power cord.
Otherwise, it may cause a fire or electrical shock.
When the product is submerged into water, always contact the service center.
Otherwise, it may cause a fire or electrical shock.
Take care so that children may not step on the outdoor unit.
Otherwise, children may be seriously injured due to falling down.
Operation
6 Air Conditioner
Safety Precautions
Installation
Install the drain hose to ensure that drain can be securely done.
Otherwise, it may cause water leakage.
Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors.
Otherwise, it may cause dispute with the neighbors.
Always inspect gas leakage after the installation and repair of product.
Otherwise, it may cause the failure of product.
Keep level parallel in installing the product.
Otherwise, it may cause vibration or water leakage.
Avoid excessive cooling and perform ventilation sometimes.
Otherwise, it may do harm to your health.
Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.
The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.
Do not use an appliance for special purposes such as preserving animals vegetables, precision machine, or art articles.
Otherwise, it may damage your properties.
Do not place obstacles around the flow inlet or outlet.
Otherwise, it may cause the failure of appliance or an accident.
Operation
Installation Manual 7
ENGLISH
The figure of product can be different according to the type of model.
Introduction
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the air conditioner.
This symbol indicates special notes.
NOTICE
Introduction
Symbols used in this Manual
8 Air Conditioner
Type "A" screw
Type "C" screwType "B" screw
The feature can be changed according to a type of model.
Remote control holder
Installation plate
Figure FigureName
Screw driver
Electric drill
Measuring tape, Knife
Hole core drill
Spanner
Torque wrench
Multi-meter
Hexagonal wrench
Ammeter
Gas-leak detector
Thermometer,
Level
Flaring tool set
Name
Installation
Installation Parts
Installation Tools
Installation
Read carefully, and then follow step by step.
Installation Manual 9
ENGLISH
Installation
Installation Map
Connecting cable (Optional Parts)
Vinyl tape (Wide)
Apply after carrying out a drainage test.
To carry out the drainage test, remove the air filters and pour water into the heat exchanger.
Saddle
Gas side piping (Optional Parts) Liquid side piping (Optional Parts) Additional drain pipe
Vinyl tape (Narrow) Drain Hose
Installation plate Sleeve Bushing-Sleeve
Putty(Gum Type Sealant)
Bend the pipe as closely on the wall as possible, but be careful that it doesn't break.
You should purchase the installation parts.
NOTICE
- The feature can be changed according a type of model.
10 Air Conditioner
Installation
Indoor unit
1. There should not be any heat or steam near the unit.
2. Select a place where there are no obstacles around of the unit.
3. Make sure that condensation drainage can be conveniently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the left (or right) of the unit is more than 10cm(3.9in). The unit should be installed as high as possible on the wall, allowing a minimum of 20cm(7.9in) from ceiling.
6. Use a metal detector to locate studs to prevent unnecessary damage to the wall.
Select the best Location
More than 20cm(7.9in)
More than
10cm(3.9in)
More than
2.4m(8ft)
More than 10cm(3.9in)
Install the indoor unit on the wall where the height from the floor is more than 2.4m(8ft).
Outdoor unit
1. If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.
2. Ensure that the space around the back and sides is more than 30cm(11.8in). The space in front of the unit should be more than 70cm(27.6in) of space.
3. Do not place animals and plants in the path of the warm air.
4. Take the weight of the air conditioner into account and select a place where noise and vibration are minimum.
5. Select a place where the warm air and noise from the air conditioner do not disturb neighbors.
More than
30cm(11.8in)
More than
30cm(11.8in)
Sunroof
Fence or
obstacles
More than
70cm(27.6in)
More than
60cm(23.6in)
Loading...
+ 21 hidden pages