- 3 -
Functions
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
Soft Dry Operation Mode
Sleep Mode Auto Control
Auto Air Control by CHAOS Logic
Airflow Direction Control
AUTO Wind
Deice(defrost) control(Heating)
Hot-start Control(Heating)
• Room temperature sensor(THERMISTOR).
• Maintains the room temperature in accordance with the Setting Temp.
• Indoor fan is delayed for 5 seconds at the starting.
• Restarting is inhibited for approx. 3 minutes.
• High, Med, Low, Chaos or Auto
• Intermittent operation of fan at low speed
• The louver can be set at the desired position or swing up
and down, right and left (not on all models) automatically.
• The fan speed is automatically switched from high to low speed.
• Both the indoor and outdoor fan stops
during deicing.
• Hot start after deice ends.
• The indoor fan stops until the
evaporator piping temperature will be
reached at 28°C.
• The fan is switched to low(Cooling), med(Heating) speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
• The fan is switched to intermittent or irregular operation.
• The fan speed is automatically switched from high to low speed.
--- Lights up in Operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Deice Mode or Hot Start Mode (only Heating Model)
--- Lights during in compressor running (for Cooling Model)
OUT
DOOR