LG LS240HE, LS090HE, LS120CE, LS240CE, LS120HE User Manual

...

LG

LG

Room Air Conditioner

OWNER'S MANUAL Prior to installation, this air-conditioning unit must be submitted for approval by

the utility service which provides electricity

(EN 61000-2, EN 61000-3 Norm).

IMPORTANT

Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner.

Please retain this owner's manual for future reference after reading it thoroughly.

ESPAÑOL FRANÇAIS ENGLISH

##############

Room Air Conditioner Owner’s Manual

 

TABLE OF CONTENTS

Safety Precautions.........................

3

Prior to Operation ..........................

9

Introduction ..................................

10

Electrical Safety ...........................

11

Operating Instructions.................

12

Maintenance and Service ............

26

FOR YOUR RECORDS

Write the model and serial numbers here:

Model #

Serial #

You can find them on a label on the side of each unit.

Dealer's Name

Date Purchased

Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.

READ THIS MANUAL

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.

You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of

Troubleshooting Tips first, you may not need to call for service at all.

PRECAUTION

Contact the authorized service technician for repair or maintenance of this unit.

Contact the installer for installation of this unit.

The air conditioner is not intended for use by young children or invalids without supervision.

Young children should be supervised to ensure that they do not play with the air conditioner.

When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts.

Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only.

2 Room Air Conditioner

Safety Precautions

Safety Precautions

To prevent the injury of the user or other people and property damage, the following instructions must be followed.

Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to properties only.

■ The meanings of the symbols used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

Installation

Do not use damaged power cords, plugs, or a loose socket.

There is risk of fire or electric shock.

For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.

There is risk of fire or electric shock.

Always use the power plug and socket with the ground terminal.

• There is risk of electric shock.

Install the panel and the

Do not modify or extend the

Do not install, remove, or re-

cover of control box securely.

power cord.

install the unit by yourself

 

 

(customer).

• There is risk of fire or electric

• There is risk of fire or electric

• There is risk of fire, electric shock,

shock.

shock.

explosion or injury.

ENGLISH

Owner’s Manual 3

Safety Precautions

Be cautious when unpacking

For installation, always

and installing the product.

contact the dealer or an

 

Authorized Service Center.

Do not install the product on a defective installation stand.

• Shape edges could cause injury.

• There is risk of fire, electric shock,

• It may cause injury, accident, or

Be especially careful of the sharp

explosion, or injury.

damage to the product.

edges.

 

 

Be sure the installation area does not deteriorate with age.

Install the indoor unit on the wall where the height from the floors more then 8ft(2.4m)

Do not handle the pipe by yourself(Costomer)

If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.

• There are sharp moving parts that

• High-Pressure refrigent may cause

could cause personal injury.

personal injury.

8ft(2.4m)

Operation

Use a dedicated outlet for this

Grasp the plug to remove the

appliance.

cord from the outlet. Do not

 

touch it with wet hands.

• There is risk of fire or electric

• There is risk of fire or electric

shock.

shock.

Do not allow water to run into electric part.

There is risk of fire, failure of the product, and/or electric shock.

4 Room Air Conditioner

LG LS240HE, LS090HE, LS120CE, LS240CE, LS120HE User Manual

Safety Precautions

Do not place a heater or other

Do not let the air conditioner

appliances near the power

run for a long time when the

cable.

humidity is very high and a

 

door or a window is left open.

• There is risk of fire, failure of the

• Moisture may condense and wet or

product, and/or electric shock.

damage furnishings.

Do not store of use flammable gas or combustibles near the air conditioner.

There is risk of fire or product failure.

ENGLISH

Do not use the product in a tightly closed space for a long time.

Oxygen deficiency could occur.

Some ventilation by opening window is necessary for the fresh air

Stop operation and close any window in storm or hurricane before the hurricane arrives.

There is risk of property damage, failure of product, or electric shock.

When flammable gas leaks, turn off the gas and open a window for ventilation before turning the product on. Do not use the telephone or turn switches on or off.

• There is risk of explosion or fire.

Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)

There is risk of physical injury, electric shock, or product.

Wax

Thinner

 

Unplug the unit if strange sounds odors or smoke comes from it.

There is risk of fire, Product faiure, and/or electric shock.

When the product is soaked (flooded or submerged), contact an Authorized Service Center.

• There is risk of electrical shock.

Owner’s Manual 5

Safety Precautions

Ventilate the product from

Unplug the appliance before

When the product is not be

time to time when operating it

performing cleaning or

used for a long time

together with a stove, etc.

maintenance.

disconnect the power supply

 

 

plug or turn off the breaker.

There is risk of fire or electrical shock.

Take care to ensure that nobody could step on or fall onto the outdoor unit.

• There is risk of electric shock.

• There is risk of product damage or

 

failure, or unintended operation.

 

 

 

 

 

 

 

 

 

 

 

 

Installation

Always check for gas(refrigerant) leakage after installation or repair of product.

• There could result in personal

• Low refrigerant levels may cause

injury and product damage.

product failure.

Install the drain hose to

Keep level even when

ensure that water is drained

installing the product.

away properly.

 

• A bad connection may cause

• To avoid vibration or water

water leakage.

leakage.

90˚

6 Room Air Conditioner

Safety Precautions

Use two or more people to lift and transport the air conditioner.

• Avoid personal injury.

Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.

There is risk of damage or loss of property.

Do not touch the metal parts of the product when removing the air filter. They are very sharp!

• There is risk of personal injury.

Operation

Do not install the product where it will be exposed to sea wind (salt spray) directly.

It may cause corrosion in the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.

Do not block the inlet or outlet of air flow.

Do not direct airflow at room occupants.

• This could damage your health.

Use a soft cloth to clean.

Do not use harsh detergents, solvents, etc.

• It may cause product failure.

• There is risk of fire, electric shock

 

or damage to the plastic parts of

 

the product.

Do not step on or put anything on the product. (outdoor unit)

There is risk of personal injury and failure of product.

Always insert the filter securely. Clean the filter every two weeks or more often if necessary.

A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.

ENGLISH

Owner’s Manual 7

Safety Precautions

Do not drink the water drained from the unit.

It is not sanitary and could cause serious health issues.

Use a firm stool or ladder when cleaning or maintaining the air conditioner.

Be careful and avoid personal injury.

Replace all the batteries in the remote.

• There is risk of fire or explosion.

Disuse

Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.

• They may burn or explode.

If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.

The chemicals in batteries could cause burns or other health hazards.

Prior to operation

Prior To Operation

PreparingForOperation

1.Contact an installation specialist for installation.

2.Plug in the power plug properly.

3.Use a dedicated circuit.

4.Do not use an extension cord.

5.Do not start/stop operation by plugging/unplugging the power cord.

6.If the cord/plug is damaged, ony replace it with an authorized replacement part.

Usage

1.Being exposed to direct airflow for a long time may be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for a long time.

2.Ventilate the room when the air conditioner is used with other heating devices. Otherwise the oxygen supply may be inadequate.

3.Do not use this air conditioner for non-specified special purpose (e.g. preserving precision devices, food, pets, plants, or art objects). Such use may damage your properties.

Cleaning And Maintenance

1.Do not touch the metal parts of the unit when removing the filter. Injury can occur.

2.Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to electric shock.

3.When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit power is accidently turned on while the interior of the unit is being cleaned.

Service

For repair and maintenance, contact your authorized service dealer.

ENGLISH

Owner’s Manual 9

Introduction

Introduction

SymbolsUsedInThis Manual

This symbol alerts you to the risk of electric shock.

This symbol alerts you to hazards that may cause harm to the air conditioner.

NOTICE This symbol indicates special notes.

Features

This appliance should be installed in accordance with national wiring regulations. This guide acts as a guide to help to explain product features.

Indoor

Air Inlet

Air Filter

Front Panel

Signal Receptor

Outdoor

(Side)

Air intake vents

Piping

Air outlet vents

10 Room Air Conditioner

Electrical Safety

Electrical Safety

• This appliance must be properly grounded.

To minimize the risk of electric shock, you must alway plug into a grounded oulet

Do not cut or remove the grounding prong from the power plug.

Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.

If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and circuit checked by a qualified electrician.

ENGLISH

Owner’s Manual 11

Operating Instruction

Operating Instruction

How ToInsertTheBatteries

Remove the battery cover by pulling it according to the arrow direction.

Insert new batteries making sure that the (+) and (-) of battery are installed correctly.

Reattach the cover by sliding it back into position.

NOTICE Use 2 AAA(1.5volt) batteries.

Do not use rechargeable batteries.

StorageAndTips ForUsingTheRemoteControler

The remote controler may be stored by mounting it on a wall.

To operate the room air conditioner, aim the remote control at the signal receptor.

Signal Receptor

Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.)

Operation Indication Lamps

OUT

DOOR

On/Off

: Lights up during the system operation, error

 

code and auto restart setting.

Sleep mode

: Lights up during sleep mode auto operation.

Plasma

: The function illustrates its dynamic mode by

 

using a multiple lighting system.

Timer

: Lights up during timer operation.

Defrost mode : Lights up during defrost mode or *hot start operation (Heat pump model only)

Outdoor unit : Lights up during outdoor unit operation. operation (Cooling model only)

Power Display : Indicates the setting temperature and operation mode.

Operation indicating lamps

12 Room Air Conditioner

Operating Instruction

RemoteControlOperations

Controls

Signal transmitter

5 1 6

 

 

 

3

4

 

 

 

2

 

CANCEL

10

 

 

7

OFF

SET

9

ON

12

11

 

AUTO CLEAN

8

 

 

17

13

 

 

18

 

 

14

 

 

 

15

 

 

16

Flip-up door (opened)

Operation Mode

Cooling Operation

Auto Operation or Auto Changeover

Healthy Dehumidification Operation

Heating Operation

• Cooling Model(), Heat Pump Model()

1. START/STOP BUTTON

Operation starts when this button is pressed and stops when the button is pressed again.

2. OPERATION MODE SELECTION BUTTON

Used to select the operation mode.

3. ROOM TEMPERATURE SETTING BUTTONS

Used to select the room temperature.

4. INDOOR FAN SPEED SELECTOR

Used to select fan speed in four steps low, medium, high and CHAOS.

5. JET COOL

Used to start or stop the speed cooling.(speed cooling operates super high fan speed in

cooling mode.)

6. CHAOS SWING BUTTON

Used to stop or start louver movement and set the desired up/down airflow direction.

7.ON/OFF TIMER BUTTONS

Used to set the time of starting and stopping operation. (See page 22)

8.TIME SETTING BUTTONS

Used to adjust the time. (See page 22)

9.TIMER SET/CANCEL BUTTON

Used to set the timer when the desired time is obtained and to cancel the Timer operation. (See page 22)

10.SLEEP MODE AUTO BUTTON

Used to set Sleep Mode Auto operation. (See page 22)

11.AIR CIRCULATION BUTTON

Used to circulate the room air without cooling or heating. (See page 23)

12.ROOM TEMPERATURE CHECKING BUTTON

Used to check the room temperature.

13.NEO PLASMA(OPTIONAL)

Used to start or stop the plasmapurification function. (See page 20)

14.HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (OPTIONAL)

Used to set the desired horizontal airflow direction.

15.RESET BUTTON

Used prior to resetting time.

16.2nd F Button

Used prior to using modes printed in blue at the bottom of buttons. (See page 21)

17.AUTO CLEAN (OPTIONAL)

Used to set Auto Clean mode.

18.˚C TO ˚F SWITCHING BUTTON

Used to switch temperature reading from Centigrade to Fahrenheit.

ENGLISH

Owner’s Manual 13

Operating Instruction

Cooling operation

1

Press the Start/Stop button.

The unit will respond with

a beep.

2

Open the door of the remote controller. To select Cooling

Operation, press the Operation Mode Selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

Changeover

Dehumidification

(Heat pump model only)

3

Close the door of the remote controller. Set the temperature

lower than the room temperature. The temperature can be

 

set within a range of 18°C~30°C(64°F~86°F) at intervals of

 

1°C(2°F).

ON

To raise the temperature

 

 

To lower the temperature

4

Set the fan speed again with the door

of the remote controller still closed.

You can select the fan speed in four steps-low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.

Gentle Breeze by the CHAOS logic

For fresher feeling, press the Indoor fan speed selector and set to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.

14 Room Air Conditioner

Auto operation (Optional)

1

Press the Start/Stop button.

The unit will respond with

a beep.

Operating Instruction

ENGLISH

2

Open the door of the remote controller. To select Auto

Operation, press the operation mode selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

 

Dehumidification

(Heat pump model only)

ON

3

The temperature and fan speed are automatically set by the

electronic controls based on the actual room temperature. If

you want to change the set temperature, press the Room Temperature Setting buttons. The cooler or warmer you feel, the more times (up to two times) you should press the button. The set temperature will be changed automatically.

To raise the temperature

To lower the temperature

During Auto Operation

You cannot control the indoor fan speed. It has already been set by the Fuzzy rule.

If the system is not operating as desired, manually switch to another mode. The system will not automatically switch from the cooling mode to the heating mode, or from heating mode to cooling mode, it must be done by manually resetting.

During Auto Operation, pressing the CHAOS swing button makes the horizontal louvers swing up and down automatically. If you want to stop auto-swing, press the CHAOS swing button again.

Owner’s Manual 15

Operating Instruction

Auto changeover operation(Optional)

1

Press the Start/Stop button.

The unit will respond with

a beep.

2

Open the door of the remote controller. To select Auto Changeover

Operation, press the Operation Mode Selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

Changeover

Dehumidification

(Heat pump model only)

Close the door of the remote controller. Set the temperature 3 lower than the room temperature. The temperature can be set within a range of 18°C~30°C(64°F~86°F) at intervals of

1°C(2°F).

To raise the temperature

ON

 

To lower the temperature

4

Set the fan speed again with the door

of the remote controller still closed.

You can select the fan speed in four steps-low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.

During Auto Changeover Operation

The air conditioner changes the operation mode automatically to keep indoor temperature. When room temperature varies over ±2°C from the set temperature, air conditioner keeps the room temperature within ±2°C of the set temperature by auto changeover mode.

16 Room Air Conditioner

Operating Instruction

Healthy dehumidification operation

1

Press the Start/Stop button.

The unit will respond with

a beep.

2

Open the door of the remote controller. To select Healthy

Dehumidification Operation, press the Operation Mode

Selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

Changeover

Dehumidification

(Heat pump model only)

3

Set the fan speed again with the door

of the remote controller still closed.

 

You can select the fan speed in four

ON

steps-low, medium, high, or CHAOS.

 

Each time the button is pressed, the

 

fan speed mode is shifted.

Gentle Breeze by the CHAOS logic

For fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the

CHAOS logic.

During Healthy Dehumidification Operation

If you select the dehumidification mode on the operation selection button, the product starts to run the dehumidification function. It automatically sets the room temp. and airflow volume to the best condition for dehumidification, based on the sensed current room temp.

In this case, however, the setting temperature. is not displayed on the remote controller and you are not able to control the room temperature. either.

During the healthy dehumidification function, the airflow volume is automatically set according to the optimization algorithm responding to the current room temp. status, so the room condition is kept healthy and comfortable even in the very humid season.

ENGLISH

Owner’s Manual 17

Operating Instruction

Heating operation (Heat pump model only)

1

Press the Start/Stop button.

The unit will respond with

a beep.

2

Open the door of the remote controller. To select Heating

Operation, press the Operation Mode Selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

Changeover

Dehumidification (Heat pump model only)

3

Close the door of the remote controller.

Set the temperature higher than the room temperature.

 

The temperature can be set within a range of

 

16°C~30°C(60°F~86°F) at intervals of 1°C(2°F).

ON

To raise the temperature

 

 

To lower the temperature

4

Set the fan speed again with the door of the

remote controller still closed. You can

select the fan speed in four steps–low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.

Gentle Breeze by the CHAOS logic

For fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.

18 Room Air Conditioner

Operating Instruction

Jet cool operation

1

Press the Start/Stop button.

The unit will respond with

a beep.

2

Press the Jet Cool button to operate

the speed cooling mode and the unit

will operate at super high fan speed on cooling mode for 30 minutes.

3

To cancel the Jet Cool mode, press the Jet Cool button, the

fan speed button or the room temperature setting button

again and the unit will operate at high fan speed on cooling mode.

or or

ENGLISH

NOTICE

During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temperature. automatically to 18°C. It is especially used to cool the room temperature. quickly in a hot summer.

In heat pump mode or auto changeover mode, however, the JET COOL function is not available.

In order to return to the normal cooling mode from the JET COOL mode, just press the operation mode selection button, airflow volume selection, temperature. setting button or the JET COOL button again.

Owner’s Manual 19

Operating Instruction

NEO PLASMA purification operation(Optional)

1

Press the Start/Stop button.

The unit will respond with a

beep.

2

Open the door of the remote

controller. Press the PLASMA

button.

Operation will start when the button is pressed and stop when the button is pressed again.

Set the fan speed again with the door of the remote

3 controller closed. You can select the fan speed in four steps-low, medium, high or CHAOS.

Each time the button is pressed, the fan speed mode is shifted.

Air purifying operation (NEO PLASMA) can be with cooling, Heating or any other operations.

NEO PLASMA Air Purifying Operation only

If you press the only PLASMA button, only

PLASMA purification function operates.

Then, fan speed is low. You can select the fan speed in four steps-low, medium, high or

CHAOS.

Each time the Indoor Fan Speed Selector button is pressed, the fan speed mode is shifted.

20 Room Air Conditioner

2nd F operation

1

Press the Start/Stop button.

The unit will respond with

a beep.

Operating Instruction

ENGLISH

2

Open the door of the remote controller and press the 2nd

Function button to operate functions printed blue color under

buttons.

(Check the indication of 2nd function on the display of the remote controller.)

CANCEL

ONOFF SET

AUTO CLEAN

3

2nd function disappears in a short time automatically or when

the button is pressed again.

For more details, refer to functions next pages.

Owner’s Manual 21

Operating Instruction

Additional Features

Sleep mode

1.Press the Sleep Mode Auto button to set the time you want the unit to stop automatically.

2.The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times. The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode Button while aiming at air conditioner.

3.Make sure the Sleep Mode Auto LED lights up .

To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star() disappears from the operation display.

NOTICE

The Sleep Mode will be operated at slow fan speed (cooling) or medium fan speed (heat pump only) for a comfortable sleep.

In cooling mode or healthy dehumidification mode:

The setting temperature will automatically rise by 1°C(2°F) over the next 30 minutes and by 2°C(4°F) in 1 hour for a comfortable sleep.

Setting the time

1.Time can be set only when you press the Reset button. When you replace the batteries, you should press the reset buttons to reset the time. Press the Start/Stop button.

2.Press 2nd F button and check if 2nd F icon is on.

3.Press the Time Setting buttons until the desired time is set.

CANCEL

4. Press the Timer SET button.

NOTICE

Check the indicator for A.M. or P.M.

Delay start/Pre-set stop

1.Make sure the time is set correctly on the display of the remote controller.

2.Press 2nd F button.

3. Press the ON/OFF Timer buttons to turn Timer on or off.

ON OFF

4. Press the Time Setting buttons until the desired time is set.

CANCEL

5. To set the selected time, press the Timer setting button aiming the remote controller at the signal receptor.

To cancel the timer setting

Check if 2nd F icon is off. CANCEL Press the Timer Cancel button aiming the remote controller at the signal receptor. (The timer lamp on the air conditioner and the display will go out.)

NOTICE

Select one of the following four types of operation.

with the unit running

 

Delay OFF Timer

Delay ON Timer

Delay OFF and ON Timer Delay ON and OFF Timer

22 Room Air Conditioner

Operating Instruction

Vertical Airflow Direction Control

The up/down airflow (Vertical Airflow) can be adjusted by using the remote control.

1. Press the Start/Stop button to start the unit.

2.Open the door on the remote control.

Press Chaos Swing button and the louvers will swing up and down. Press the Chaos Swing button again to set the vertical louver at the desired airflow direction.

Air Circulation Mode

NOTICE

If you press the CHAOS swing button, the vertical airflow direction is changed automatically based on the CHAOS algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable, as if enjoying a natural breeze.

Always use the remote control to adjust the up/down airflow direction. Manually moving the vertical airflow direction louver by hand could damage the air conditioner.

When the unit is shut off, the up/down airflow direction louver will close the air outlet vent of the system.

To adjust left/right(Horizontal Airflow) direction

Ensure unit is turned off before adjusting the horizontal airflow direction control. Carefully open vertical louver to

allow access to the horizontal airflow direction.

Adjust the left/right airflow direction by hand.

Circulates the room air without cooling or heating.

1.Press the Start/Stop button. the unit will respond with a beep.

2.Open the door on the remote control. Press the Air Circulation button. Close the door on the remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is shifted from low to CHAOS and back to low again.

ENGLISH

CHAOS Air

Fan speed is on low. Fan speed is on medium. Fan speed is on high.

NOTICE

CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically changed from high to low or vice versa, depending on the ambient temperature.

Owner’s Manual 23

Operating Instruction

Auto clean (Optional)

AUTO CLEAN

NOTICE

1.Whenever you press the AUTO CLEAN button, Auto Clean Function will be reserved and cancelled.

2.Auto Clean function works before and after cooling or dehumidification mode.

For details, refer to the below points.

3.When the unit is started after the reservation of Auto Clean ,the Cool Start function operates and indoor Fan is started after 20 seconds.

4.When you press Start/Stop button to turn off the unit after the you have reserved Auto Clean function, the air-conditioner circulates the indoor air in the Auto

Clean mode with no more Cooling or Dehumidification operation. It lasts for 30 minutes.

5.If you press the AUTO CLEAN button again during the product operation , Auto Clean function will be cancelled.

During Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy Dehumidification Operation can be removed.

During Auto Clean function, only Start/Stop button, Plasma button and AUTO CLEAN button are available.

Forced operation

Operation procedures when the remote control can't be used.

The operation will be started if the ON/OFF button is pressed.

If you want to stop operation, re-press the button.

 

 

 

ON/OFF

 

 

 

 

button

 

Cooling Model

 

Heat pump Model

 

 

Room Temp. 24°C(75.2°F)

21°C(69.8°F) Room Temp. < 24°C(75.2°F)

Room Temp. < 21°C(69.8°F)

 

 

Operating mode

Cooling

Cooling

Healthy Dehumidification

Heating

Indoor FAN Speed

High

High

High

High

Setting Temperature

22°C(71.6°F)

22°C(71.6°F)

23°C(73.4°F)

24°C(75.2°F)

Test operation

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes.

During test operation, if remote controller signal is received, the unit operates as remote controller sets.

If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1 "beep".

If you want to stop the operation, re-press the button.

24 Room Air Conditioner

Operating Instruction

Auto restart

In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.

So there is no need of activating this function by pressing any key or button.

In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode.

Helpful information

 

Fan speed and cooling capacity.

 

The cooling capacity indicated in the specification is the value

 

when the fan speed is set to high, and the capacity will be lower

High

at low or medium fan speed.

Speed

High fan speed is recommended when you wish to cool the room

 

quickly.

 

NOTICE

Auto restart function has set enable as factory default.

But customer can set up by following this instruction.

To disable function

-Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) blinks 4 times.

To enable function

-Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) brights 4 times.

ENGLISH

Owner’s Manual 25

Maintenance and Service

Maintenance And Service

Before performing any maintenance, turn off the main power to the system.

IndoorUnit

Grille, Case, and Remote Control

Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.

NOTICE

Supply power must be disconnected before cleaning the indoor unit.

Air filters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air inlet vent

Air outlet vent

 

Air filters

 

 

 

 

 

 

 

 

(behind front panel)

 

 

 

 

Vertical louver Horizontal

 

louver

The air filters behind the front grille should be checked and cleaned once in every 2 weeks or more often if neccessary.

1.Open the front panel as shown.

2.Pull the filter tab slightly forward to remove the filter.

3.Clean the filter with a vacuum cleaner or warm, soapy water.

If dirt is conspicuous, wash with a solution of detergent in lukewarm water.

If hot water (40°C(104°F) or more) is used, it may be deformed.

4.After washing with water, dry well in the shade.

5.Re-install the air filter.

NEO PLASMA filter (Optional)

The NEO PLASMA filter behind the air filters should be checked and cleaned once in every 3 months or more often if necessary.

1.After removing the air filters, pull slightly forward to remove the NEO PLASMA filter.

2.Clean NEO PLASMA filter with the vacuum cleaner.

If it is very dirty, wash it with water.

3.Note the cuts of electric discharge lines.

4.Re-install the NEO PLASMA filter to the original position.

TRIPLE DEODORIZER filter (Optional)

1.After removing the air filters, pull slightly forward to remove the TRIPLE DEODORIZER filter.

2.Dry in the sunlight for two hours.

3.Re-install the TRIPLE DEODORIZER filter to the original position.

TRIPLE DEODORIZING Filter

NEO PLASMA Filter

Don't touch this NEO PLASMA Filter within 10 seconds after opening he inlet grille,

it may cause an electric shock.

Never use any of the followings:

Water hotter than 40°C(104°F)

Could cause deformation and/or discoloration.

Volatile substances

Could damage the surfaces of the air conditioner.

s

o

line

26 Room Air Conditioner

Maintenance and Service

OutdoorUnit

The heat exchanger coils and panel vents of the outdoor unit should be checked regularly.

If clogged with dirt or soot, the heat exchanger

and panel vents may be professionally steam cleaned.

NOTICE

Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.

(Side)

Air intake

vents

Piping

Air outlet vents

ENGLISH

CommonProblems And Solutions

Before calling for service

If you have problems with your air conditioner, read the following information and try to solve the problem. If you cannot find a solution, turn off the air conditioner and contact your dealer.

Air conditioner does not operate

1.Ensure that the air conditioner is plugged into a proper outlet.

2.Check the fuse or circuit breaker.

3.Check whether the voltage is unusually high or low.

Air does not feel cold enough on the cooling setting

1.Ensure that the temperature settings are correct.

2.Check to see if the air filter is clogged with dust. If so, replace the filter.

3.Ensure that the air flow from the outside is not obstructed and that there is a clearance of over 20" between the back of the air conditioner and the wall or fence behind it.

4.Close all doors and windows and check for any source of heat in the room.

Before calling for service, please review the following list of common problems and solutions.

The air conditioner is operating normally when:

You hear a pinging noise. This is caused by water being picked up by the fan on rainy days or in highly humid conditions. This feature is designed to help remove moisture in the air and improve cooling efficiency.

You see water dripping from the rear of the unit. Water may be collected in the base pan in highly humid conditions or on rainy days. This water overflows and drips from the rear of the unit.

You hear the fan running while the compressor is silent. This is a normal operational feature.

Owner’s Manual 27

Loading...
+ 60 hidden pages