LG LP-K2060CL/CA, LP-K3020CL/CA, LP-K4020CL/CA, LP-K3060CL/CA Service Manual

Package Air Conditioner
SERVICE MANUAL
MODEL: LP-K2060CL/CA
LP-K3060CL/CA LP-K3020CL/CA LP-K4020CL/CA
Contents
–2–
–3–
Indoor Unit
Power Switch ON/OFF
Operation Mode Control
Indoor Fan Speed Control
Jet Cool
Energy Saving
Room Temperature control
Auto Operation
Soft Dry Operation Mode
Time Delay Safety Control
Fan Operation
AutoRestart
• Cooling, Auto, Soft Dry
• High, Low
• Speed Cooling operates super high fan speed in cooling mode
• Maintains the room temperature in accordance with the Setting Temp.
• Up: up to 30°C
• Down: down to 16°C
• The setting temperature, indoor fan speed and desired operation mode are automatically set.
• Intermittent operation of fan at low speed.
• Restarting is inhibited for approx. 3 minutes.
• Used to circulate room air without cooling.
• The power comes on again after a power failure.
Functions
–4–
• The setting temperature indoor fan speed and desired operation mode are automatically set.
• Intermittent operation of fan at low speed.
• Used to circulate room air without cooling.
• OFF Timer (1, 2, 3,......7 hour)
• Speed cooling operates super high fan speed in cooling mode.
• Airflow direction Auto-swing and Manual Contol.
• Up: up to 30°C
• Down: down to 16°C
• High, Low
Remote Control
Operation ON/OFF
Cooling Operation Mode
Auto Operation Mode
Sot Dry Operation Mode
Fan Operation
Timer Control
Jet Cool
Energy Saving
Airflow Direction Control
Room Temperature Control
Indoor Fan speed control
Product Specifications (Cooling model only)
–5–
POWER SUPPLY Ø, V, Hz COOLING CAPACITY Btu/hr HEATING CAPACITY Btu/hr
(Incl. elec. Heater) POWER INPUT COOLING W
HEATING W RUNNING COOLING A CURRENT HEATING A
MODEL
MAKER
TYPE COMPRESSOR CAPACITY Btu/hr
INPUT (KW)
LRA A NOISE LEVEL INDOOR dB(A)
OUTDOOR dB(A) AIR INDOOR
CFM/CMM
CIRCULATION OUTDOOR
CFM/CMM REFRIGERANT (R-22) OZ(kg) HEAT INDOOR R/C/FPI EXCHANGER OUTDOOR R/C/FPI FAN INDOOR TYPE
OUTDOOR TYPE
ROOM TEMPERATURE CONTROL
WIDTH
INDOOR HEIGHT inch(mm)
DEPTH WIDTH
OUTDOOR HEIGHT inch(mm)
DEPTH
NET WEIGHT
INDOOR Ib(kg) OUTDOOR Ib(kg)
CONNECTIONS
LIQUID inch(mm) GAS inch(mm)
1, 220-240, 50
27,800
-
3,000
-
14.5
-
H25B35QABHA
BRISTOL
RECIPRO
30,200
2.83 85 48 58
670/19
2,046/58
63.5(1.8) 3/22/18 2/24/18
SIROCO
PROPELLER
MICOM CONTROL
19.68(500)
70.86(1800)
12.59(320)
34.25(870)
25.78(655)
12.59(320)
88.18(40)
138.6(63)
3/8"(Ø9.52)
5/8"(Ø15.88)
1, 220,60
36,000
-
3,500
-
17
-
CR38K6-PFV-502
COPELAND
RECIPRO
38,200
3.52 102
52 62
741/21
2,225/63
84.6(2.4) 3/22/18 2/30/18
SIROCO
PROPELLER
MICOM CONTROL
19.68(500)
70.86(1800)
12.59(320)
34.25(870)
31.49(800)
12.59(320)
88.18(40)
147.7(67)
3/8"(Ø9.52)
5/8"(Ø15.88)
ITEMS
UNIT
MODEL
LP-K4020CL/CALP-K3060CL/CA
D
I M E N S
I O N S
Dimensions
Indoor Unit
Air Outlet Vent
Remote Signal Receptor
Air Intake Vent
Air Intake Vent
(Rear)
Air Outlet
Vent
INDOOR UNIT OUTDOOR UNIT
HEAT EXCHANGER
HEAT EXCHANGER
COMPRESSOR
GAS SIDE
LIQUID SIDE
COOLING HEATING
REVERSING VALVE
CHECK VALVE
CAPILLARY TUBE
CAPILLARY TUBE
BY PATH CAPILLARY TUBE
–6–
Outdoor Unit
Refrigeration Cycle Diagram
Wiring Diagram
(1) • LP-K3060CL/CA
LP-K3020CL/CA
INDOOR UNIT OUTDOOR UNIT
DISPLAY PCB ASM
CA MODEL
MAIN PCB ASM
RY-S/HIGH
RY-AIRC
BK
CN-DISP(1) CN-DISP(2)
CN1 CN2
ROOM
TH
DOOR S/W
BK
RD
BK WH RD
HVB ASM
A/CL UNIT
OR
BR YL
Ci
WH BK BL RD
GN/YL
RY-COMP
RY-SYNC
(250V/3A)
SM
EVAP
TH
RY-HIGH RY-MID RY-LO
RD
GN/YL
WH BK
BK
GN/YL
BL BR
FUSE
CN-GND
GN/YL
P/No.; 3854A90012Q
CIRCUIT DIAGRAM
FAN
MOTER
COMP.
POWER RELAY
POWER INPUT
HIDDEN LINE:FIELD WIRING
(CONNETING CABLE)
CAPACITOR
BR
BR
BR
BL
BR
OR
BR BL
BL
TERMINAL BLOCK(6P)
1
F1
F2
2 3 4
GN/YL
5 6
BL BK
BK
BL
BL
BK
BK
BR
C
R
S
RD BL
OR YL
GN/YL
2 6 4 801
CAPACITOR
FAN
MOTOR
NOTE
BL BK BR RD OR WH YL GN/YL:GREEN/YELLOW
BLUE BLACK BROWN RED ORANGE WHITE YELLOW
: : : : : : :
–7–
Wiring Diagram
(2) Indoor Unit
• LP-K4020CL
(3) Outdoor Unit
• LP-K4020CL
–8–
NOTE
SM Ci FMi THi Co FMo Cr 52C Tmo1,2 CM 63H
SYNCHRONOUS MOTOR CAPACITOR FOR FAN(INDOOR) INDOOR FAN MOTOR THERMISTOR FOR INDOOR TEMP. CAPACITOR FOR FAN(OUTDOOR) OUTDOOR FAN MOTOR RUN CAPACITOR FOR COMP. MAGNATIC CONTACTOR TERMINAL BLOCK(OUTDOOR) COMPRESSOR MOTOR HIGH PRESSURE SWITCH
NOTE
RD BL BK WH GY
RED BLUE BLACK WHITE GRAY
: : : : :
BR VT GN OR GN
BROWN VIOLET GREEN ORANGE GREEN/YELLOW
: : : : /YL :
FIELD WIRING
INDOOR UNIT CIRCUT DIAGRAM
DISPLAY PCB ASM
RY-SH
OR
BR YL
Ci
WH
BK BL
RY-COMP
RY-SYNC
(250V 3A)
SM
FMi
THi
RY-H RY-MID
BK
WH
RD
BK WH RD
FUSE
CONNECT TO
OUTDOOR UNIT
NOTE
CM Co
FMo Cr 52C Tmo1,2 63H
COMPRESSOR MOTOR CAPACITOR FOR FAN (OUTDOOR) OUTDOOR FAN MOTOR RUN CAPACITOR FOR COMP. MAGNATIC CONTACTOR TERMINAL BLOCK(OUTDOOR) HIGH PRESSURE SWITCH
RD BL BK WH GY
RED BLUE BLACK WHITE GRAY
: : : : :
BR VT GN OR GN
BROWN VIOLET GREEN ORANGE GREEN/YELLOW
: : : : /YL :
FIELD WIRING
OUTDOOR UNIT CIRCUT DIAGRAM
CONNECT TO INDOOR UNIT
P/No.: 3854AP2708P
CM
POWER SUPPLY
1ø, 220V, 60Hz
Tmo1
1 2 3 4 5 6
L1T1L2
T2
52C
B
A
FMo
OR
RD
WH
BR
BK
BK
WH
WH
Tmo2
RD
RDWHBK
WH
GN/YL
RD
RD
BK
BK
63H
FUSE
250V
5 A
WH
R
S
C
WH
PTCR
Cr
BK
BK YL
Co
FUSE
250V
5 A
BR
OR
(CAUTION)
1. This product is only for 1ø, 220V, 60Hz.
2. "Check List" before test run. 1st: Reconfirm the wiring connecting of compresssor,
outdoor unit motor.
2st: Fasten the screw of Terminal block
'Tmo1' once more.
–9–
(1) The function of main control
1. Time Delay Safety Control
ƒU3min¡ƒ The compressor is ceased for 3 minutes to balance the pressure in the refrigeration cycle.
(Protection of compressor)
ƒU3sec¡ƒ The indoor fan is ceased for 3 seconds to prevent relay noise.
(Protection of fan relay and micro chip)
ƒU30sec¡ƒThe 4-way valve is ceased for 30 sec. to prevent the refrigerant-gas abnormal noise when the Heating
operation is OFF or switched to the other operation mode.
2. Airflow Direction Control
ƒUThis function is to swing the louver left and right automatically and to set it at the desired position. ƒUThe procedure is as the following.
1st : Press the ON/OFF Button to operate the product. 2nd : Press the Airflow Direction Control Button to swing the louver left and right automatically.
(Remote controller)
3rd : Repress the Airflow Direction Control Button to set the louver as the desired position.
(Remote controller)
ƒU8HP Model don't have this function.
3. Cooling Mode Operation
ƒUWhen selecting the Cooling( ) Mode Operation, the unit will operate according to the setting by the
controller and the operation diagram is as following.
Intake Air temp.
Setting Temp. +1°C
(Compressor ON)
Setting Temp. -1°C (Compressor OFF)
Indoor Fan Speed
Selecting
fan speed
Selecting
fan speed
Selecting
fan speed
Selecting
fan speed
Selecting
fan speed
3 minutes
More than
3 minutes
More than
Compressor ON OFF ON OFF ON
Operation Details
–10–
4. Auto Operation (Cooling Model only)
ƒUThe operation procedure is as following.
ƒUAuto Operation for Cooling
Press Start/Stop Button
Select Auto Operation Mode
Check the Room temperature
Operation Condition Intake-air Temperature Setting temperature Fan speed
Over 26°C 25°C Over 24°C~below 25.5°C Intake air -1.0°C Over 22°C~below 23.5°C Intake air -0.5°C
below 21.5°C Intake air Temperature(18°C, MAX)
When Switch to
Auto Operation
Controlled
by Fuzzy logic
Intake Air Temp.
Indoor Fan Speed
Compressor ON OFF
Fuzzy Speed
ON OFF
Setting Temp. +1°C
(Compressor ON)
Setting Temp. -1°C (Compressor OFF)
3 minutes
More than
3 minutes
More than
5. Off Timer Function
This function is to set the time of stopping the unit operation. The procedure is as the following.
1st: Press the timer set button on the Remocon. 2nd: The buzzer sounds and then the display window shows the Off-Time to be set as
- The Off-Time is shifted as the following by each press.
- If you select ' ', the Off-Timer function will be cancelled.
- During Off-Timer Operation, if you repress the timer set button, the rest time will be displayed.
....
–11–
9. Child Lock function
This function is to operate Air conditioner only by Remocon. The procedure is as the following 1st: Press the 2 buttons of the temperature control simultaneously, to raise-to lower on the Display Panel of the
product for more 3 seconds.
2nd: The buzzer sounds and then the window of Display Panel shows
CCLL
(CL) mark.
3rd: To release this function, the reverse again the operating procedure could be done. During this function is operating, any buttons of Display Panel don't work. But it is possible to operate with
Remote controller.
7. Protection of the evaporator pipe from frosting
• Compressor and outdoor fan stop when indoor pipe temperature is below -2°C and restart at the pipe temperature is above 12°C.
8. Air Purifying Operation(CA Model only)
6. Soft Dry Operation Mode
• During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 2°C, the compressor
OFF temperature is the setting temperature minus 1°C.
• When the room temperature rises over the compressor ON temperature, the operation mode is switched to the Cool-
ing mode.
• When the room temperature falls between the compressor ON temperature and OFF temperature, the operation
mode is switched to the Soft Dry Operation.
• The operation diagram is shown below.
Intake Air Temp.
Indoor Fan Speed
LOW
Selecting
fan speed
Selecting
fan speed
LOW LOW LOW LOW
Compressor OFFON ONON OFF OFF ON
LOW
OFF
Setting Temp. +2°C
(Compressor ON)
Setting Temp. -1°C
(Compresso OFF)
Operation
Cooling
Cooling
operation
Dry operation
3 min. 3 min.
10 min.
maximum
7 min.
maximum
10 min.
Mode Selecting
Operating Mode
Fan Speed
Outdoor OFF
Initial Starting of Air purifying Operation
- Low at the initial
- But could be switched to Med. Hi
OFF
- Outdoor not operating
- Fan operating + Air puri­fying operating
Repress Air
purifying
Button or
ON/OFF
Button
When switched to Air purifying operation
Selecting Speed of Main Operating Mode
ON or OFF depend on main operat­ing
- Outdoor operating
- Main Operating + Air purifying operating
10. Alarm mode display / only displayed while operating.
CCOO
: The sensor for sensing room temperature is open or short.
11. Jet Cool
During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed
setting the room temp. automatically to 18°C. It is especially used to cool the room temp. in the shortest time in a hot summer. In heat pump mode or neuro fuzzy mode however, the JET COOL function is not available.
You can select this function during the operation of Cooling/ Soft Dry/ Auto/ Fan.When it is selected, JET COOL lamp is on immediately and fan speed graphic(red) is on 3 times off.Possible to select or cancel using JET COOL key.To cancel the JET COOL Mode, press the JET COOL button again or the Fan Speed button or the Room
Temperature Setting button and the unit will operate in high Fan speed on Cooling mode(set up to 18°C).
During the operation when it stops and runs again setting up is high fan speed on cooling mode(set up to
18°C).
12. Energy Saving
If setting temperature of starting energy saving operation is under 22°C, first, setting temperature it up to
22°C and perform energy saving operation.
After energy saving operation starts, if adaptation time of the human body pass from the point which room
temperature and setting temperature meet together, increase setting temperature 1°C more.
➂ If it doesn't satisfy number ➀ even in 50 minutes from the start of energy saving operation, increase 1°C. ➃ After increasing setting temperature 1°C more by number ➀, ➁, perform number ➁, ➂ again, if setting tem-
perature goes up to 25°C, maintain this temperature.
If setting temperature goes down to under 25°C, during the operation, do number , , again.
13. AUTO RESTART
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.
In case the air conditioner does not receive any signal from the remote control, it will turn off automatically after 7 hours.
–12–
Setting energy
saving operation
Setting temp.
23˚C
21˚C
22˚C
23˚C
24˚C
25˚C
26˚C
27˚C
Setting temp.
24˚C
Setting temp.
25˚C
maintains setting temp.
25˚C
28min.
50min. 50min. 50min.
35min. 47min.
14. Function for test operation
1) Outline of Operation
- This is for checking the condition of installation during the installation, and it is operated by cooling, Fan speed is high, comp. on, and Auto air flow operations without setting temperature.
2) Operation or Cancel
- Do test operation, if you push ON/OFF button and the down room temperature checking button over 3 sec­onds at the same time.
- During the operation, if you push the stop button or push ON/OFF button and the down room temperature checking button over 3 seconds at the same time, the test operation will be cancelled and unit come to rest.
- During the operation, if you input remocon key or key on Display panel, it performs its duties.
3) Function
- It operates cooling, fan speed is high, comp. on for 18 ± 1 minutes, regardless of room temperature.
- After 18 ± 1 minutes of operation, it becomes off itself.
- During the operation, signal
8888
stands for "
LLoo
"
–13–