Lg Lmu365hv, Lmu186hv, Lmu245hv, Lmu185hv Owner's Manual

ENGLISH FRANÇAIS ESPAÑOL
LG Multi-Type Air Conditioner
OWNER'S MANUAL
LG
TYPE: Standard
Artcool Mirror Ceiling Cassette
IMPORTANT
• Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after reading it thoroughly.
2 Multi Air Conditioner
Multi-Type Air Conditioner Owner’s Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call for service at all.
PRECAUTION
Contact the authorized service technician for
repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by
young children or invalids without supervision.
• Young children should be supervised to ensure
that they do not play with the air conditioner.
• When the power cord is to be replaced,
replacement work shall be performed by authorized personnel only using only genuine replacement parts.
A. Safety Precautions...............................3
B. Electrical Safety ...................................6
Temporary Use of an Adapter.......................6
Symbols used in this Manual ........................6
C. Product Introduction ...........................7
Indoor Units...................................................7
Outdoor Unit..................................................7
D. Operating Instructions ........................8
How to insert the Batteries ............................8
Wireless Remote Controller Maintenance.....8
Operation Indication Lamps ..........................9
Operating Method .........................................9
Wireless Remote Controller ........................10
Wired Remote Controller
(Ceiling Cassette Type Optional) ................11
Operation Mode ..........................................12
Healthy Dehumidification Operation............13
Air Circulation Operation .............................13
Auto Operation ............................................13
Jet Cool Operation ......................................14
NEO PLASMA Purification Operation
(Optional) ....................................................14
Auto Clean(Optional)...................................15
Display Luminosity
(Artcool Mirror Type Only)...........................15
Forced operation .........................................16
Setting the Current Time .............................17
Timer Setting...............................................17
To cancel the Timer Setting ........................17
Up/Down Airflow Direction Control..............18
Left/Right Airflow Direction Control
(Optional) ....................................................18
Auto Restart Function .................................18
E. Maintenance and Service ..................19
Standard/Artcool Mirror Type ......................19
Ceiling Cassette Type .................................20
Operation Tips!............................................21
Self-Diagnosis Function ..............................21
Owner's Manual 3
Safety Precautions
ENGLISH
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
Be sure not to do.
Be sure to follow the instruction.
Always use a power plug and socket with a ground terminal.
• There is a risk of electric shock.
Do not use a defective or underrated circuit breaker. Use the correctly rated breaker and fuse.
• There is risk of fire or electric shock .
Do not use a multi consent. Always use this appliance on a dedicated cicuit and breaker.
• Otherwise it can cause electric shock or fire.
For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. Do not disassemble or repair the product by yourself.
• There is risk of fire or electric shock.
Always ground the product as per the wiring diagram. Do not connect the ground wire to gas or water pipes lightening rod or telephone ground wire.
• There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
• There is risk of fire or electric shock due to dust , water etc.
Use the correctly rated breaker or fuse.
• There is risk of fire or electric shock.
Do not modify or extend the power cable. If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced.
• There is risk of fire or electric shock.
For installation, removal or reinstall , always contact the dealer or an Authorized Service Center.
• There is risk of fire, electric shock, explosion, or injury.
Do not install the product on a defective installation stand. Be sure that the installation area does not deteriorate with age.
• It may cause product to fall.
Never install the outdoor unit on a moving base or a place from where it can fall down.
• The falling outdoor unit can cause damage or injury or even death of a person.
When the product is soaked (flooded or submerged) in water , contact an Authorized Service Center for repair before using it again.
• There is risk of fire or eletric shock.
In outdoor unit the step-up capacitor supplies high voltage electricity to the electrical components. Be sure to discharge the capacitor completely before conducting the repair work.
• An charged capacitor can cause electrical shock.
When installing the unit, use the installation kit provided with the product.
• Otherwise the unit may fall and cause severe injury.
Be sure to use only those parts which are listed in the svc parts list. Never attempt to modify the equipment.
The use of inappropriate parts can cause an electrical shock, excessive heat generation or fire.
4 Multi Air Conditioner
Safety Precautions
Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals.
• Improper or loose connections can cause heat generation or fire.
Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after installation or svc and then tear away and thraw away the plastic packaging bags.
• Children may play with them and cause injury.
Make sure to check that the power cable plug is not dirty, loose or broken and then only insert the plug completely.
• Dirty, loose or broken power plug can cause electric shock or fire.
Be sure to check the refrigerant to the used. Please read the label on the product.
• Incorrect refrigerant used can prevent the normal operation of the unit.
Don't use a power cord, a plug or a loose socket which is damaged.
• Otherwise it may cause a fire or electrical shock.
Do not touch , operate, or repair the product with wet hands. Hold the plug by hand when taking out
• There is risk of electric shock or fire.
Do not place a heater or other heating appliances near the power cable.
• There is risk of fire and electric shock.
Do not allow water to run into electric parts. Install the unit away from water sources.
• There is risk of fire, failure of the product, or electric shock.
Do not store or use or even allow flammable gas or combustibles near the product.
• There is risk of fire.
Do not use the product in a tightly closed space for a long time. Perform ventilation regularly.
• Oxygen deficiency could occur and hence harm your health.
Do not open the front grille of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)
• There is risk of physical injury, electric shock, or product failure.
If strange sounds, smell or smoke comes from product.Immediately turn the breaker off or disconnect the power supply cable.
• There is risk of electric shock or fire.
Ventilate the product room from time to time when operating it together with a stove, or heating element etc.
• Oxygen deficiency can occur and hence harm your health.
Turn the main power off and unplug the unit when cleaning or repairing the product.
• There is risk of electric shock.
When the product is not to be used for a long time, disconnect the power supply plug or turn off the breaker.
• There is risk of product damage or failure, or unintended operation.
Take care to ensure that nobody especially kids could step on or fall onto the outdoor unit.
• This could result in personal injury and product damage.
Take care to ensure that power cable could not be pulled out or damaged during operation.
• There is risk of fire or electric shock.
Do not place ANYTHING on the power cable.
• There is risk of fire or electric shock.
Do not plug or unplug the power supply plug to turn the unit ON/OFF .
• There is risk of fire or electric shock.
When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on.
• Do not use the telephone or turn switches on or off. There is risk of explosion or fire.
Two or more people must lift and transport the product.
• Avoid personal injury.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
• It may cause corrosion on the product.
Install the drain hose to ensure that the condensed water is drained away properly.
• A bad connection may cause water leakage.
Keep level even when installing the product.
• To avoid vibration or noise.
Do not install the product where the noise or hot air from the outdoor unit could damage or disturb the neighborhoods.
• It may cause a problem for your neighbors and hence dispute.
Always check for gas (refrigerant) leakage after installation or repair of product.
• Low refrigerant levels may cause failure of product.
Owner's Manual 5
Safety Precautions
ENGLISH
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.
• There is risk of damage or loss of property.
Do not block the inlet or outlet of air flow.
• It may cause product failure.
Use a soft cloth to clean. Do not use harsh detergents, solvents or splashing water etc .
• There is risk of fire, electric shock, or damage
to the plastic parts of the product.
Do not touch the metal parts of the product when removing the air filter.
• There is risk of personal injury.
Do not step on or put anyting on the product. (outdoor units)
• There is risk of personal injury and failure of product.
Always insert the filter securely after cleaning. Clean the filter every two weeks or more often if necessary.
• A dirty filter reduces the efficiency.
Do not insert hands or other objects through the air inlet or outlet while the product is operating.
• There are sharp and moving parts that could cause personal injury.
Be cautious when unpacking and installing the product.
• Sharp edges could cause injury.
If the refrigerant gas leaks during the repair, do not touch the leakaing refrigerant gas.
• The refrigernat gas can cause frostbite (cold burn)
Do not tilt the unit when removing or uninstalling it.
• The condensed water inside can spill .
Do not mix air or gas other than the specified refrigerant used in the system .
• If air enters the refrigerant system, an excessively high pressure results, causing equipment damage or injury.
If the refrigerant gas leaks during the installation, ventilate the area immediately.
• Otherwise it can be harmfull for your health.
Dismantling the unit, treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards.
Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries.
• There is risk of fire or product failure.
Do not recharge or disassemble the batteries. Do not dispose off batteries in a fire.
• They may burn or explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.
• The chemicals in batteries could cause burns or other health hazards.
If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked.
• The chemicals in batteries could cause burns or other health hazards.
Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
• Moisture may condense and wet or damage furniture.
Do not expose your skin or kids or plants to the cool or hot air draft.
• This could harm to your health.
Do not drink the water drained from the product.
• It is not sanitary and could cause serious health issues.
Use a firm stool or ladder when cleaning, maintaining or repairing the product at an height.
• Be careful and avoid personal injury.
6 Multi Air Conditioner
Electrical Safety
Electrical Safety
• This appliance must be properly grounded. To minimize the risk of electric shock, you must alway plug into a grounded oulet.
• Do not cut or remove the grounding prong from the power plug.
• Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
• If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and circuit checked by a qualified electrician.
We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use only a genuine adapter, available from most local hardware stores. Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.
• Never use the appliance with a broken adapter.
Temporary Use of an Adapter
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the air conditioner.
This symbol indicates special notes.
NOTE
Symbols used in this Manual
ENGLISH
Owner's Manual 7
Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your indoor unit type.
The figure can be changed according to model.
Product Introduction
Product Introduction
Indoor Units
Connection pipe Drain hose
Connecting wire
Control cover
Air intake vents
Outdoor Unit
[Standard Type] [Artcool Mirror Type]
Air inlet
Plasma filter (Optional)
Grille tab
Front grille
ON/OFF button
Air inlet
Air filter
Plasma filter
Air filter
Air outlet
Louvers
(Vertical blades)
(Horizontal blade)
Flap
Front Panel
Signal
receiver
Air discharge
Front panel
Signal receiver
[Ceiling Cassette Type]
Signal receiver
ON/OFF button
Cabinet
Air Discharge
Air Inlet
Air outlet vents
Base plate
Operating Instructions
How to insert the Batteries
Wireless Remote Controller Maintenance
1. Remove the battery cover by pulling it according to the arrow direction.
2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly.(Battery Size = AAA)
3. Reattach the cover by sliding it back into position.
1. Always use/replace both batteries of same type.
2. If the system is not to be used for a long time, remove the batteries to save their working life.
3. If the display screen of remote controller starts, fading replace both of the batteries.
NOTE
1. Choose a suitable place where its safe & easy to reach.
2. Fix the holder to wall etc with the supplied screws firmly.
3. Slide the remote controller inside the holder.
1. Remote controller should never be exposed to direct sunlight.
2. Signal transmitter & receiver should always be clean for proper communication. Use a soft cloth to clean them.
3. In case some other appliances also get operated with remote control, change their position or consult your serviceman.
NOTE
8 Multi Air Conditioner
Operating Instructions
Owner's Manual 9
ENGLISH
Operating Instructions
1. The signal receiver is inside the unit.
2.
Aim the remote controller towards the unit to operate it. There should not be any blockage in between.
Operating Method
On/Off
: Lights up during the system operation, error code and auto restart setting.
Sleep mode : Lights up during sleep mode auto operation.
Plasma : The function illustrates its dynamic mode by using a multiple lighting system.
Timer
: Lights up during timer operation.
Defrost mode
Power Display : Indicates the setting temperature and operation mode.
: Lights up during defrost mode or *hot start operation
* Hot start operation: Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out
from unit. * In defrost mode unit stops heating operation for few minutes to remove formation of ice on the heat exchanger coils to maintain the efficiency.
Operation
mode
Shape of
display
Setting
temperature
Standard Too hot Hot Cold Too cold
Jet
Cool
Auto
clean
Comfortable
Auto operation mode
Cooling, heating, Dehumidification
Mode
[Standard/Artcool Mirror Type]
[Ceiling Cassette Type]
: Lights up during the system operation.
Filter Sign : Lights up after 2400 hours from the time of first operating unit.
Timer : Lights up during Timer operation.
Defrost Mode : Lights up during Defrost Mode or Hot Start operation.(Heat pump model only)
On/Off
Forced
: To operate the unit when the remote control can't be used for any reason.
Operation Indication Lamps
Standard Type
Standard Type
Artcool Mirror Type
Artcool Mirror Type
Ceiling Cassette Type
Ceiling Cassette Type
10 Multi Air Conditioner
Operating Instructions
Wireless Remote Controller
PLASMA Button (Optional)
Used to start or stop the plasma-purification function.
JET COOL Button
Speed cooling operates super high fan speed.
OPERATION MODE SELECTION Button
Used to select the operation mode.
FUNCTION SETTING Button
Used to set or clear Auto Clean or Amart Clean.
LCD LUMINOSITY Button (Optional)
Used to adjust LCD luminosity
SMART CLEAN Button (Optional)
Used to start or stop Smart Clean.
CLEAR ALL Button
Used to clear all timer.
ROOM TEMPERATURE SETTING Button
Used to select the room temperature.
ON/OFF Button
Used to turn on/off the unit.
INDOOR FAN SPEED SELECTION Button
Used to select fan speed in four steps low, medium, high and chaos.
UP/DOWN AIRFLOW Button
Used to stop or start louver movement and set the desired up/down airflow direction.
LEFT/RIGHT AIRFLOW Button(Optional)
Used to set the desired left/right(horizontal) airflow direction.
TIMER AND TIME SETTING Button
Used to set the time of starting or stopping and sleeping operation.
ROOM TEMPERATURE CHECKING Button
Used to check the room temperature.
°C/°F SWITCH Button
Used to switch temperature reading from Celsius to Fahrenheit.
RESET Button
Used to reset the remote controller.
8
1
2
3
4
5
6
7
Operation Mode
Cooling Mode
Auto Operation
Dehumidification mode
Heating Mode
Fan Mode
Cooling Model( ), Heat Pump Model( )
9
10
11
12
13 14
15
16
Owner's Manual 11
ENGLISH
Wired Remote Controller (Ceiling Cassette Type Optional)
Display temperature can be different from actual room temperature if the remote controller is
installed at the place where sun-rays are falling directly or the place nearby heat source.
The actual product can be different from above contents depending upon model type.
OPERATION INDICATION SCREEN
SET TEMPERATURE Button
WIRELESS REMOTE CONTROLLER RECEIVER
Some products don't receive the wireless signals.
VENTILATION Button
OPERATION MODE SELECTION Button
SUBFUNCTION Button
FUNCTION SETTING Button
EXIT Button
ON/ OFF Button
ROOM TEMPERATURE Button
FAN SPEED Button
AIR FLOW Button
RESERVATION/ TIME SETTING Button
SETTING/ CANCEL Button
UP, DOWN, LEFT, RIGHT Button
RESET Button
1
9
11
12
3
5
6
2
4
16
10
13
14
7
8
15
NOTE
12 Multi Air Conditioner
Operating Instructions
Operation Mode
To lower the temperature
To raise the temperature
4
2
1 3
Cooling
Auto
Operation
Healthy
Dehumidification
Heating
(Heat pump model only)
Air Circulation
CHAOS Air Fan speed is on low. Fan speed is on medium. Fan speed is on high.
Press the ON/OFF BUTTON to turn the unit on. The unit will respond with a beep.
Open the door of the remote controller and press the operation mode button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS. For cooling the temperature can be set within 18°C~30°C(64°F~86°F) and for heating the temperature range is 18°C~30°C(60°F~86°F).
Set the fan speed with the remote controller. You can select the fan speed in four steps-low, medium, high and CHAOS by pressing the INDOOR FAN SPEED SELECTOR BUTTON. Each time the button is pressed, the fan speed mode is shifted.
1
2
3
4
Natural wind by the CHAOS logic
For fresher feeling, press the INDOOR FAN SPEED SELECTOR BUTTON selector and set to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.
Owner's Manual 13
ENGLISH
Operating Instructions
High
Speed
High Speed
Helpful information
Fan speed and cooling capacity. The cooling/heating capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool/heat the room quickly.
Healthy Dehumidification Operation
This operation circulates the air without cooling or heating. It can be activated by pressing the OPERATION MODE SELECTION BUTTON. Once the air circulation is activated you can select the air speed by pressing the INDOOR FAN SPEED SELECTOR BUTTON.
CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically changed from high to low or vice versa, depending on the ambient temperature.
NOTE
Air Circulation Operation
During Healthy Dehumidification Operation
If you select the dehumidification mode on the OPERATION MODE SELECTION
BUTTON, the product starts to run the dehumidification function. It automatically sets the room temperature and airflow volume to the best condition for dehumidification,
based on the sensed current room temperature. In this case, however, the setting temperature is not displayed on the remote controller and you are not able to control the room temperature either. During the healthy dehumidification function, the airflow volume is automatically set
according to the optimization algorithm responding to the current room temperature
status, so that the room condition is kept healthy and comfortable even in the very
humid season.
In this operation mode the actual setting temperature and the fan speed are automatically set by the electronic control logic based on the current room temperature. If you feel hot or cold press the temperature setting buttons respectively for more cooling or heating effect.
NOTE : You cannot set the actual setting temperature and the indoor fan
speed in this operation mode. But you can use the Chaos swing in this operation. If the system is not operating as desired, switch manually to another mode.
Auto Operation
14 Multi Air Conditioner
Operating Instructions
Jet Cool Operation
Jet cool function can be used to cool the room quickly in hot summer. When this
function is turned on, the air conditioner runs in cooling operation mode with super high fan speed and 18°C setting temperature for 30 minutes for fast and effective cooling.
You can activate this operation by pressing the JET COOL BUTTON. To change from jet cool mode to high fan speed cooling mode, press the JET COOL BUTTON or INIDOOR FAN SPEED SELECTOR BUTTON or the ROOM TERPERATURE SETTING BUTTON again.
Jet cool function cannot be activated during heating mode.
Art Cool and Art Cool Wide models close the side discharges during jet cool operation, for strong cooling.
NOTE
NEO PLASMA Purification Operation (Optional)
Plasma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air by generating a plasma of high charge electrons. This plasma kills and destroys the contaminants completely to provide clean and hygienic air.
Plasma purification can be started by pressing the PLASMA BUTTON on the remote controller. Repressing it will deactivate the operation.
This feature can be used in any operation mode and any fan speed can be used while plasma filter is functioning.
NOTE
PLASMA
Owner's Manual 15
Operating Instructions
ENGLISH
During auto clean function, moistures left in indoor units after cooling operation or healthy dehumidification
operation can be removed.
Auto Clean(Optional)
This function operate when the unit is turned off.
Press the FUNCTION SETTING button 1 time. Auto Clean symbol will blink.
1
Press the SET/CLEAR button to reserve or cancel the Auto Clean function.
If the Auto Clean function is reserved, whenever the unit is turned off, the indoor fan is still running for about 30 minutes internally without cooling or dehumidification operation. Also the louver is closed. This dries up any remains of moisture & cleans the unit internally.
2
Display Luminosity (Artcool Mirror Type Only)
The Display Luminosity can be adjusted by using the remote control. Open the door of the remote controller, and press the LCD LUMINOSITY button. Display will be dark. Press the button again to set bright display.
Because Display Luminosity is optional function, some product will not operate.
16 Multi Air Conditioner
Operating Instructions
Forced operation
Operation procedures when the remote control can't be used. The operation will be started if the ON/OFF button is pressed. If you want to stop operation, re-press the button.
ON/OFF
button
ON/OFF
button
Forced Operation Button
[Ceiling Cassette Type]
[Standard Type][Artcool Mirror Type]
Room Temp. 24°C(75.2°F)
21°C(69.8°F) Room Temp. < 24°C(75.2°F)
Room Temp. < 21°C(69.8°F)
Operating mode Cooling Healthy Dehumidification Heating
Indoor FAN Speed
High High High
Setting Temperature
22°C(72°F) 23°C(74°F) 24°C(76°F)
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes. During test operation, if remote controller signal is received, the unit operates as remote controller sets. If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1 "beep". If you want to stop the operation, re-press the button.
Owner's Manual 17
ENGLISH
Operating Instructions
If you wish to cancel all timer setting, press the CLEAR ALL button.
If you wish to cancel each timer setting, press the
TIMER button to turn timer sleep or on or off as you want. And then press the SET/CLEAR button aiming the remote controller at the signal receptor. (The timer lamp on the air conditioner and the display will go off.)
1. Press the TIMER button for 3 seconds.
2. Press TIME SETTING buttons until the desired time is set.
Check the indicator for A.M. and P.M.
3. Press the SET / CLEAR button.
NOTE
Timer Sleep Timer On Timer Off
1. Press the TIMER button to turn timer on or off.
2. Press TIME SETTING buttons
until the desired time is set.
3. Press the SET / CLEAR button.
Select one of the following 3 types of operation.
NOTE
Setting the Current Time
To cancel the Timer Setting
Timer Setting
18 Multi Air Conditioner
Operating Instructions
This feature is enabled by factory default setting, but you can disable it by pressing the ON/OFF button for 6 seconds. The unit will beep twice and the indicator lamp will blink 4 times. To enable it, press the button again for 6 seconds. The unit will beep twice and the indicator lamp will blink 4 times.
NOTE
This function is useful in the situation of power failure. When power regains after a failure this feature restore the previous operating condition and the air conditioner will run in the same settings.
Auto Restart Function
The up/down airflow (Vertical Airflow) can be adjusted by using the remote controller.
1. Press the ON/OFF button to start the unit.
2. Press UP/DOWN AIRFLOW button and the louvers will swing up and down. Press the UP/DOWN AIRFLOW button again to set the vertical louver at the desired airflow direction.
If you press the UP/DOWN AIRFLOW button, the horizontal airflow direction is changed automatically based on the Auto Swing algorithm to distribute the air in the room evenly and at the same time to make the human body feel more comfortable, as if enjoying a natural breeze.
Always use the remote controller to adjust the up/down airflow direction. Manually moving the vertical airflow direction louver by hand, could damage the air conditioner.
When the unit is shut off, the up/down airflow direction louver will close the air outlet vent of the system.
The left/right(horizontal) airflow can be adjusted by using the remote control.
1. Press the ON/OFF button to start the unit.
2. Press the LEFT/RIGHT AIRFLOW button and the louvers will swing left and right. Press the Horizontal Airflow Direction Control Button again to set the horizontal louver at the desired airflow direction.
Up/Down and Left/Right Airflow function isn’t shown on display of remote controller.
NOTICE
Up/Down Airflow Direction Control
Left/Right Airflow Direction Control (Optional)
Owner's Manual 19
ENGLISH
Plasma filter
Deodorizer filter
Don't touch this plasma filter within 10 seconds after opening the inlet grille, it may cause an electric shock.
Removal of Filters
Open the front panel as shown. Then pull the filter tab slightly forward to remove the air filter. After removing the air filter remove the plasma and deodorizer filter by slightly pulling forward.
Plasma filter
Front panel
Maintenance and Service
Standard/Artcool Mirror Type
Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and unplug the power cord.
Clean the unit with a soft dry cloth. Do not use bleach or abrasives.
Never use any of these
Water hotter than 40°C(104°F). It may cause deformation and discoloration.
Volatile substances. They may damage the surface of the air
conditioner.
Air Filters
The air filters behind the front panel / grill should be checked and cleaned once in every 2 weeks or more often if necessary. To remove the filters see the self explanatory diagrams for each model type. Clean the filters with a vacuum cleaner or warm soapy water. If dirt is not easily removed, wash with a solution of detergent in luke warm water. Dry well in shade after washing and reinstall the filters back in place.
Plasma Filters
The plasma filters behind the air filter should be checked and cleaned once in every 3 months or more often if necessary. To remove the filters see the self explanatory diagrams for each model type. Clean the filters with a vacuum cleaner. If it is dirty wash it with water and dry well in shade an install back in place.
Deodorizer Filters
Remove the deodorizer filters behind the air filter and expose them in direct sunlight for 2 hours. And then insert these filters into original position.
Maintenance and Service
G
a
s
o
l
i
n
e
P
o
w
d
e
r
Plasma filter
Deodorizer filter
[Artcool Mirror Type]
[Standard Type]
20 Multi Air Conditioner
Maintenance and Service
How to use the front panel [Artcool Mirror Type]
1. Front panel closing
Move the link upward and close the front panel.
2. Front panel removing
Raise the link up to hook hanger and remove front panel forward.
Ceiling Cassette Type
Grille, Case and Remote Control
Turn the system off before cleanining, To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.
Supply power must be disconnected before cleaning the indoor unit.
Air Filters
The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if neccessary.
Never use any of the followings:
Water hotter than 40°C. Could cause deformation and/or discoloration.
Volatile substances. Could damage the surfaces of the air conditioner.
B
e
n
z
e
n
e
S
C
O
U
R
I
N
G
C
L
B
A
R
G
E
R
S
I
N
N
E
R
1
Remove the Air filters.
Take hold of the tab and pull slightly forward to remove the filter.
CAUTION:
When the air filter is to be removed, do not touch the metal parts of the indoor unit.
It may cause an injury.
2
Clean dirt from the air filter using a vacuum cleaner or washing with water.
If dirt is conspicuous, wash with a neutral detergent in lukewarm water.
If hot water (50°C or more) is used, it may be deformed.
3
After washing with water, dry well in the shade.
Do not expose the air filter to direct sunlight or heat from a fire when drying it.
4
Install the air filter.
NOTE
Loading...
+ 44 hidden pages