LG LMDN186HV Parts manual

LG Air Conditioner
SVC MANUAL(Exploded View)
MODEL : AMNW09GL1A0 [LMDN096HV] AMNW12GL2A0 [LMDN126HV] AMNW18GL2A0 [LMDN186HV]
Type: Ceiling Concealed Duct
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
Internal Use Only
http://biz.lgservice.com
- 2 -
Copyright ©2013 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
1. Specification
Indoor
Note:
1. Wiring cable size must comply with the applicable local and national code.
2. Due to our policy of innovation some specifications may be changed without notification.
3. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased(maximum 3dB(A)) owing to ambient conditions during operation.
Conversion Formula kW = Btu/h x 0.0002931 cfm = CMM x 35.3
Model Name
AMNW09GL1A0
[LMDN096HV]
Power Supply V, Ø, Hz 208/230, 1, 60
Capacity Btu/h class 9,000
Dimensions Body
W x H x D mm 700 × 190 × 700
W x H x D inch 27-9/16 x 7-15/32 x 27-9/16
Net Weight Body kg (lbs) 17.5 (38.6)
Heat Exchanger
(Row x Column x Fins per inch) x No. - (2 x 11 x 14) x 1
Face Area m2(ft2) 0.12 (1.32)
Fan
Type - Sirocco Fan
Air Flow Rate
High-static Mode (Factory Set)
H / M / L m3/min 9.0 / 7.0 / 5.5
H / M / L ft3/min 318 / 247 / 194
External
Static
Pressure
Pa (mmAq) 24.5 (2.5)
Fan Motor
Type - BLDC
Output W x No. 19 x 1
Dehumidification Rate l/h (pts/h) 1.1 (2.3)
Sound Pressure Level H / M / L dB(A) 30 / 26 / 23
Sound Power Level Max. dB(A) 49
Piping Connections
Liquid mm(inch) Ø 6.35 (1/4)
Gas mm(inch) Ø 9.52 (3/8)
Drain (O.D. / I.D.) mm(inch) Ø 32.0(1-1/4) / 25.0(31/32)
Safety Devices
- Fuse
- -
Power and Communication Cable (included Earth) No. x mm2(AWG) 4C x 0.75 (18)
- 3 -
Copyright ©2013 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Note:
1. Wiring cable size must comply with the applicable local and national code.
2. Due to our policy of innovation some specifications may be changed without notification.
3. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased(maximum 3dB(A)) owing to ambient conditions during operation.
Conversion Formula kW = Btu/h x 0.0002931 cfm = CMM x 35.3
Model Name
AMNW12GL2A0
[LMDN126HV]
AMNW18GL2A0
[LMDN186HV]
Power Supply V, Ø, Hz
Capacity Btu/h class
Dimensions Body
W x H x D mm
W x H x D inch
Net Weight Body kg (lbs)
Heat Exchanger
(Row x Column x Fins per inch) x No. -
Face Area m2(ft2)
Fan
Type -
Air Flow Rate
High-static Mode (Factory Set)
H / M / L m3/min
H / M / L ft3/min
External
Static
Pressure
Pa (mmAq)
Fan Motor
Type -
Output W x No.
Dehumidification Rate l/h (pts/h)
Sound Pressure Level H / M / L dB(A)
Sound Power Level Max. dB(A)
Piping Connections
Liquid mm(inch)
Gas mm(inch)
Drain (O.D. / I.D.) mm(inch)
Safety Devices
-
-
Power and Communication Cable (included Earth) No. x mm2(AWG)
208/230, 1, 60
18,000
900 × 190 × 700
35-7/16 x 7-15/32 x 27-9/16
22.0(48.5)
(2 x 11 x 18) x 1
0.17 (1.81)
Sirocco Fan
15.0 / 12.5 / 10.0
530 / 441 / 353
24.5 (2.5)
BLDC
19 x 1, 5 x 1
1.7 (3.6)
36 / 34 / 31
54
Ø 6.35 (1/4)
Ø 12.7 (1/2)
Ø 32.0(1-1/4) / 25.0(31/32)
Fuse
-
4C x 0.75 (18)
208/230, 1, 60
12,000
900 × 190 × 700
35-7/16 x 7-15/32 x 27-9/16
22.0(48.5)
(2 x 11 x 18) x 1
0.17 (1.81)
Sirocco Fan
10.0 / 8.5 / 7.0
353 / 300 / 247
24.5 (2.5)
BLDC
19 x 1, 5 x 1
1.2 (2.6)
31 / 28 / 27
52
Ø 6.35 (1/4)
Ø 9.52 (3/8)
Ø 32.0(1-1/4) / 25.0(31/32)
Fuse
-
4C x 0.75 (18)