1. Specification
Note:
1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 26.7˚C(80˚F) DB/19.4˚C(67˚F)
- Outdoor Temperature 35˚C(95˚F) DB/23.9˚C(75˚F)
Heating: - Indoor Temperature 21.1˚C(70˚F) DB/15.6˚C(60˚F) WB
- Outdoor Temperature 8.3˚C(47˚F) DB/6.1˚C(43˚F) WB
Piping Length - Interconnecting Piping Length 7.5m(24.6 ft.)
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement.
4. For more Capacity(*),refer to the combination table
Conversion Formula kW = Btu/h class X 0.0002931 cfm = CMM x 35.3
Power Supply Ø / V / Hz Capacity(*) Btu/h class Current Running Current A Fan Motor Type
Fan Type Motor Output(W) x No. of Unit Air Flow Rate CMM (H / M / L) CFM External Static Pressure mmAq Capacitor µF / Vac
Drive Coil Row x Column x FPI Dimensions Body mm(inch) (W x H x D) Decorative Panel mm(inch) Net Weight Body kg (lbs)
Decorative Panel kg (lbs) Air Filter Sound Level (H / M / L) dB(A)+3 Piping Liquid mm (inch) Connections Gas mm (inch)
Drain(OD/ID) mm(inch) Dehumidification Rate l/h Safety Devices Temperature Sensor Referigerant Referigerant Control Transmission Interunit Cable No. x AWG
Model AMNW18GD8R1[LMAN185HVT]
Indoor unit type ART COOL Mirror
1/ 208~230/ 60
18,000
0.15
BLDC
Cross Flow Fan
25.6 x 1
12.6/11.5/10 445/406/353
-
­Direct Drive 2Rx15Cx20
1,107 x 299 x 200 (43 9/16 x 12 x 7 7/8)
-
14.1(31.09)
-
Long life filter
39/37/35
6.35 (1/4)
12.7 (1/2)
20/16 (0.787/0.630)
2
Fuse, Thermal Protector for Fan Motor
Thermistor
R410A
EEV(in Outdoor unit)
4X18(Including Earth)
- 3 -
Copyright ©2009 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
2. List of Functions
Note :
O : Applied, X : Not applied, – : No relation Option: Model name & price are different according to options, and assembled in factory with main unit. Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
Air supply outlet 1 Airflow direction control(left & right) Auto Airflow direction control(up & down) Auto Auto swing(left & right) O
Air flow Auto swing(up & down) X
Airflow steps(fan / cool / heat) 3 / 4 / 3 Chaos swing O Chaos wind(auto wind) O Jet cool(Power wind) O Swirl wind X Deodorizing filter O
Air purifying Plasma air purifier O
Prefilter(washable / anti-fungus) O Drain pump -
Installation E.S.P. control -
Electric heater(operation) ­High ceiling operation ­Hot start O
Reliability Self diagnosis O
Soft dry operation O Auto changeover X Auto cleaning O Auto operation(artificial intelligence) O Auto restart operation O Child lock -
Convenience Energy-Saving Cooling Mode X
Forced operation O Group control ­Sleep mode O Timer(on/off) O Timer(weekly) ­Two thermistor control ­Wide wired remote controller O (PQRCUSA0)
Deluxe wired remote controller ­Individual Simple wired remote controller O (PQRCUCA0) control Simple wired remote controller(for hotel use) -
Wireless remote controller(simple) X
Wireless LCD remote control X
Wireless LCD remote control(Ez) O
General central controller (Non LGAP) X CAC network
Dry contact Accessory(PQDSB) function
Central control(LGAP) X
PDI(power distribution indicator) X
PI 485 X Special CTIE X function kit Zone control ­Others Thermistor -
FunctionCategory
AMNW18GD8R1[LMAN185HVT]