Lg Lman125hvt, Lman095hvt Owner's Manual

Multi Air Conditioner
SVC MANUAL(Exploded View)
MODEL : AMNW09GDER1(LMAN095HVT) AMNW12GDER1(LMAN125HVT)
CAUTION
Before Servicing the unit, read the safety precautions in Standard SVC manual. Only for authorized service personnel.
http://biz.lgservice.com
1. Specification
Indoor unit type ART COOL Mirror
Model AMNW09GDER1[LMAN095HVT] AMNW12GDER1[LMAN125HVT]
Power Supply Ø / V / Hz
Capacity(*) Btu/h class
Current Running Current A
Fan Motor Type
Fan Type
Motor Output(W) x No. of Unit
Air Flow Rate CMM
(H / M / L) CFM
External Static Pressure mmAq
Capacitor µF / Vac
Drive
Coil Row x Column x FPI
Dimensions Body mm(inch)
(W x H x D) Decorative Panel mm(inch)
Net Weight Body kg (lbs)
Decorative Panel kg (lbs)
Air Filter
Sound Level (H / M / L) dB(A)+3
Piping Liquid mm (inch)
Connections Gas mm (inch)
Drain(OD/ID) mm(inch)
Dehumidification Rate l/h
Safety Devices
Temperature Sensor
Referigerant
Referigerant Control
Transmission Interunit Cable No. x AWG
1/ 208~230/ 60 1/ 208~230/ 60
9,000 12,000
0.15 0.15
BLDC BLDC
Cross Flow Fan Cross Flow Fan
7.8 x 1 7.8 x 1
8.0/7.0/5.0 10.0/8.0/6.0
282/247/177 353/282/212
--
--
Direct Drive Direct Drive
2R x 15C x 18 2R x 15C x 18
915 x 282 x 165 (36 x 11 3/32 x 6 1/2) 915 x 282 x 165 (36 x 11 3/32 x 6 1/2)
--
9.5(20.9) 9.5(20.9)
--
Long life filter Long life filter
31/26/22 35/28/24
6.35 (1/4) 6.35 (1/4)
9.52 (3/8) 9.52 (3/8)
20/16 (0.787/0.630) 20/16 (0.787/0.630)
1.2 1.5
Fuse, Thermal Protector for Fan Motor Fuse, Thermal Protector for Fan Motor
Thermistor Thermistor
R410A R410A
EEV(in Outdoor unit) EEV(in Outdoor unit)
4X18(Including Earth) 4X18(Including Earth)
Note:
1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 26.7˚C(80˚F) DB/19.4˚C(67˚F)
Heating: - Indoor Temperature 21.1˚C(70˚F) DB/15.6˚C(60˚F) WB
Piping Length - Interconnecting Piping Length 7.5m(24.6 ft.)
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement.
4. For more Capacity(*),refer to the combination table
Copyright ©2009 LG Electronics. Inc. All right reserved.
- Outdoor Temperature 35˚C(95˚F) DB/23.9˚C(75˚F)
- Outdoor Temperature 8.3˚C(47˚F) DB/6.1˚C(43˚F) WB
- Level Difference of Zero
- 2 -
Only for training and service purposes
Conversion Formula kW = Btu/h class X 0.0002931 cfm = CMM x 35.3
LGE Internal Use Only
2. List of Functions
FunctionCategory
Air supply outlet 1 1 Airflow direction control(left & right) Auto Auto Airflow direction control(up & down) Auto Auto Auto swing(left & right) O O
Air flow Auto swing(up & down) X X
Airflow steps(fan / cool / heat) 3 / 4 / 3 3 / 4 / 3 Chaos swing O O Chaos wind(auto wind) O O Jet cool(Power wind) O O Swirl wind X X Deodorizing filter O O
Air purifying Plasma air purifier O O
Prefilter(washable / anti-fungus) O O Drain pump - -
Installation
Reliability Self diagnosis O O
Convenience Energy-Saving Cooling Mode X X
Individual control
CAC network function
Special CTIE X X function kit Zone control - ­Others Thermistor - -
E.S.P. control - ­Electric heater(operation) - ­High ceiling operation - ­Hot start O O
Soft dry operation O O Auto changeover X X Auto cleaning O O Auto operation(artificial intelligence) O O Auto restart operation O O Child lock - -
Forced operation O O Group control - ­Sleep mode O O Timer(on/off) O O Timer(weekly) - ­Two thermistor control - ­Wide wired remote controller O (PQRCUSA0) O (PQRCUSA0) Deluxe wired remote controller - ­Simple wired remote controller O (PQRCUCA0) O (PQRCUCA0) Simple wired remote controller(for hotel use) Wireless remote controller(simple) X X Wireless LCD remote control X X Wireless LCD remote control(Ez) O O General central controller (Non LGAP) X X Dry contact Accessory (PQDSB) Accessory (PQDSB) Central control(LGAP) X X PDI(power distribution indicator) X X PI 485 X X
AMNW09GDER1[LMAN095HVT] AMNW12GDER1[LMAN125HVT]
--
Note :
O : Applied, X : Not applied, – : No relation Option: Model name & price are different according to options, and assembled in factory with main unit. Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
Copyright ©2009 LG Electronics. Inc. All right reserved. Only for training and service purposes
- 3 -
LGE Internal Use Only
Loading...
+ 4 hidden pages