Please read this manual carefully before operating
your set and retain it for future reference.
MODEL
LCP2840-DN/DP
LCP2840I-DN/DP
1504 (V7.0)
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK
OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
This lightning flash with arrowhead
symbol within an equilateral
triangle is intended to alert the
user to the presence of uninsulated
dangerous voltage within the
product’s enclosure that may be of
sufficient magnitude to constitute a
risk of electric shock to persons.
The exclamation point within an
equilateral triangle is intended
to alert the user to the presence
of important operating and
maintenance (servicing) instructions
in the literature accompanying the
product.
This Class A digital apparatus complies with Canadian
ICES-003.
Cet appareil numérique de la classe A est conforme à la
norme NMB-003 du Canada.
Warning
• Do not install this equipment in a confined space such
as a bookcase or similar unit.
• Wiring methods shall be in accordance with the
National Electric Code, ANSI/NFPA 70.
• This is a class A product. In a domestic environment
this product may cause radio interference in which
case the user may be required to take adequate
measures.
• To reduce a risk of fire or electric shock, do not expose
this product to rain or moisture.
Caution:
• This installation should be made by a qualified service
person and should conform to all local codes. Refer
servicing to qualified personnel only.
• The apparatus shall not be exposed to water (dripping
or splashing) and no objects filled with liquids, such as
vases, shall be placed on the apparatus.
LG Electronics hereby declares that this/
these product(s) is/are in compliance
with the essential requirements and
other relevant provisions of Directive
2004/108/EC and 2011/65/EU.
Contact office for compliance of this
product :
LG Electronics Inc.
EU Representative, Krijgsman 1,
1186 DM Amstelveen, The Netherlands
Privacy zone feature enables users to veil unwanted
zones. This setting is used for masking unwanted
zones, hiding them from display on the monitor
screen. Up to 8 zones can be registered.
Introduction
About Dome Camera
The dome cameras are designed for installation in an
indoor or outdoor video surveillance system.
The camera incorporates the digital signal processor,
pan/tilt mechanism, x28 zoom lens and RS-485
communication interface in a compact outdoor enclosure.
Features
m High Sensitivity Support
The camera provides the high quality picture with 4.5
mm (1/4 Type) Super HAD II CCD.
m Preset Position
Preset position is the function to register camera
monitoring positions (preset positions). By using
LKD1000 controller, you can register presets with
position number. Maximum 128 Preset Position are
available. By entering the position numbers, you can
move cameras to the preset positions. The moving
speed and holding time are adjustable.
m Preset Tour
Preset Tour is the function to go through all the
registered camera monitoring positions (preset
positions).
m Preset Group Tour
A preset tour is composed of a group of preset
positions that the operator can program to be linked
together in a sequence. A preset group should have a
maximum of 9 preset positions.
m Auto Pan
The camera has an Auto Pan function that enables to
keep surveillance on every detail occurring around
the specific area, which is preset to watch in advance.
The camera can pan among the maximum 8 points
you will set. The moving speed and holding time are
adjustable.
m Auto Flip
When the camera is operated to tilt through the 90°, it
can be watched the opposite side of the locations by
Auto Flip of a 180° horizontally.
m Optical Zoom
The optical zoom range is 1x to 28x.
m Digital Zoom
Digital zoom enhances the systems zoom range to 12
times beyond the 28x optical zoom limit. By utilizing
the digital zoom function, the total system zoom
range increases further from 28x (1x digital zoom) to
336x (12x digital zoom)
m Sensor Linkage
The camera is capable of capturing a subject by the
focus of camera moving promptly toward the subject
at the rate of 120° / s when the camera works with
a detector (magnetic, beam, infrared rays), and a
subject moving within a detection area is captured by
a detector.
m Alarm In function
Alarm input signals are supplied from external devices
through the ALARM IN connector to activate 'go to
preset' function.
m Pattern recording function
A routine of manual operations can be stored and
reproduced repeatedly. The Pan, Tilt and Zoom
controls are available for pattern recording.
Note:
The available total time of pattern differs depending
on camera’s operation. When the pattern recording is
full, the pattern recording will automatically stop.
m Controls by General Controller
This camera can be controlled by RS-485. Especially
the camera has an excellent cost-saving effect
because it can be controlled by the general RX point
of contact signal.
m Connects with the maximum 256 cameras
This camera can be utilized after being connected
with maximum 256 cameras.
Therefore, it is capable of performing an excellent job
in the large buildings or department stores.
5
m Day & Night Function
This camera can be selected Color or Black & White.
You can set Color in the daytime and Black & White at
night due to the low illumination. (Filter Conversion
type)
m DSS (Digital Slow Shutter) function
It is possible to highly sensitive surveillance because
of DSS(Digital Slow Shutter) function.
m WDR (Wide Dynamic Range) function
The camera can be best condition to watch easily
inside or outside in the strong back light.
m Power Supply
This camera must always be operated a DC 12 V
Certified/Listed, class 2 power supply only.
Safety Precautions
m Do not attempt to disassemble the camera
To prevent electric shock, do not remove screws or
covers. There are no user serviceable parts inside. Ask
a qualified service personnel for servicing.
m Avoid the camera with direct sunlight
Do not aim the camera at bright objects. Whether
the camera is in use or not, never face it with direct
sunlight or other extremely bright objects.Otherwise
blooming or smear may be caused.
door opening and closing.
• Use in an environment where eyeglasses become
foggy.
• Use in a room filled with cigarette smoke or dust.
If the lens becomes cloudy due to condensation,
remove the dome cover and wipe all moist surfaces
with a soft cloth.
m Before operating, please check proper
temperature, humidity and power source ratings.
Use the camera under conditions where temperature
is between -20 °C to 50 °C and humidity is below 80
%. The input power source is DC 12 V.
m Consumables
Parts having contacts such as the lens-drive motors,
cooling fan built inside the camera are subject to wear
with time. About replacement and maintenance of
such parts, please ask the nearest service center.
m Handle the camera with care
Do not abuse the camera. Avoid striking, shaking, etc.
The camera could be damaged by improper handling
or storage.
m Do not use strong solvents or detergents
Use a dry cloth to the camera when it is dirty. If it is
hard to remove the dirt on the camera, use a mild
detergent and wipe it gently.
m Do not install this camera upside down
This camera is designed for mounting on the ceiling
or wall.If you install this camera upside down,
for example, mounted on the floor, it may cause
malfunction.
m Do not use the camera in such places as shown
below.
The lens may become cloudy due to condensation if
the camera is used under the following conditions.
• Rapid temperature fluctuation by switching an air
conditioner on and off.
• Rapid temperature fluctuation due to frequent
6
Identication of Camera
“A”
a
LCP2840-DN/LCP2840-DP
d
a Camera mounting bracket
b Dome camera body
e
c Dome cover assembly
f
d Video output cable with BNC connector
g
Connects with the video connector of the monitor.
e Power cable (DC 12 V)
f Data Communication Terminal - RS-485
g Data Communication Terminal - Alarm Input
h Fall Prevention Wire
Be sure to hook the fall prevention wire into a bracket.
Caution:
When you fix the dome cover to the dome camera
body, you must insert the wire in the dome camera
body. If not, the wire may obstruct the camera’s
moving.
Introduction
b
c
h
Do not expose the power and data cable to
“A”
housing and damage the camera. If you must, please
make sure that the connections are sealed tightly.
After installing the camera, you should arrange the
cables using the outlet box to protect the cables.
moisture, this may cause leakage into the
7
“A”
a
LCP2840I-DN/LCP2840I-DP
a Camera mounting bracket (Optional)
d
b Dome camera body
e
c Dome cover assembly
f
d Video output cable with BNC connector
g
Connects with the video connector of the monitor.
e Power cable (DC 12 V)
f Data Communication Terminal - RS-485
g Data Communication Terminal - Alarm Input
h Fall Prevention Wire
Be sure to hook the fall prevention wire into a bracket.
Caution:
When you fix the dome cover to the dome camera
body, you must insert the wire in the dome camera
body. If not, the wire may obstruct the camera’s
moving.
Do not expose the power and data cable to
“A”
housing and damage the camera. If you must, please
make sure that the connections are sealed tightly.
After installing the camera, you should arrange the
cables using the outlet box to protect the cables.
moisture, this may cause leakage into the
b
h
c
8
Installation
Installation Precautions
The following steps of installation and connection work
should be done by qualified service personnel or system
installers and should conform to all local codes.
Before you install and connect the camera, check and
prepare the required peripheral devices and cables.
Before you connect the camera, turn off all devices to be
connected, such as this camera and DVR.
Note:
Do not touch the dome cover’s window.
Camera Installation Location
Discuss the installation location for the camera with your
retailer, and select a place that is strong enough for the
installation.
• Install the camera on a ceiling (concrete, etc.) at a
location that is sufficiently strong to support it.
• Install the camera body on the foundation section
of the building or sections having sufficient bearing
strength.
About Static Electricity Removal
Before installing the camera, touch a metal case or other
metallic parts with your hand to remove static electricity
from your body.
Do not install in areas subjected to high amounts of
humidity or dust.
Doing so may cause internal components to damage
more easily or malfunction.
Do not wire cables near power lines.
Tightening the Screws
Screws should be tightened sufficiently in accordance
with the materials and structure of the installation
location. After tightening the screws, visually inspect
them to make sure there is no unevenness and that each
screw is tight.
Removing the Protection Tape
Model LCP2840-DN/DP is used for the description,
operation and details provided in this operating guide.
Before using the camera, remove the protection tape.
Loosen the screws using the wrench and remove the
dome cover as shown below. Remove the protection tape
and attach the dome cover.
Installation
Never install or use the camera in the following
locations
• Do not install it in areas exposed to direct sunlight or
rain.
• Do not install the camera near the air outlet of an air
conditioner.
• Near a swimming pool or other areas where chemicals
are used.
• Food preparation areas and other locations where
there are large amounts of steam vapor and oil, in
flammable atmospheres, other special environments.
• Areas where radiation, X-rays, strong electric waves, or
magnetism is generated.
• At sea, in coastal areas, or in areas where corrosive gas
is being generated.
• Areas outside of the allowable ambient operating
temperature range
• When installing the camera on a ceiling of insufficient
strength, reinforce the ceiling.
Caution:
Remove the protection tape carefully.
9
Mounting the Camera
Surface mount
The figures show an example of the camera mounted on
a ceiling or wall with a locally procured bracket.
Note:
The camera have not been evaluated for wall or ceiling
mounting.
Ceiling mount
CeilingCeiling
LCP2840-DN/LCP2840-DP
LCP2840I-DN/LCP2840I-DP (Optional)
10
Note:
(B)
(A)
When you install the camera
to the ceiling mount, you
must drill a hole in the camera body as shown right. (ø
5.0)
Pendant mount (Optional)
Install pipe and camera as shown below.
Installation
11
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.