LG G5300 Schematics 1

12. AUTO CALIBRATION
12.1 Overview
AutoCal (Auto Calibration) is the PC side calibration tool that perform Rx and Tx calibration with Agilent 8960 or other equipment. AutoCal generate calibration data by communicating with phone and measuring equipment and write it into calibration data block of flash memory in GSM phone.
12.2 Requirements
• AutoCal.exe
• GSM phone
• Agilent 8960 ( or other equipment )
12.3 Menu and settings
• Edit ➞ Ramp : Show reference power ramp window. Reference ramp is used in APC
procedure. You can open or save reference ramp data and edit it on notepad.
12. AUTO CALIBRATION
Figure 12-1. Reference ramp window.
• Edit Make bin & write : Make binary file from measured calibration data and write to the
phone. The name of binaryfile is cal.bin by default. You can change it at Option Settings Bin files tab.
• Edit Make bin as : Make binary file as the other name.
• Edit- Make RF & BB bin : Make RF(AGC, APC) bin and BB(ADC) bin separately.
- 127 -
- 128 -
12. AUTO CALIBRATION
Connection Connect to phone : Connect to the phone which you want to measure. This
procedure checks whether the PC is connected to “Ag8960” or not. If not connected to “Ag8960” try to connect to “Ag8960”. After that it performs sync. procedure with phone. If the sync. procedure is successful state column on statusbar changed to SETUP else you should disconnect phone and try it again from the beginning. All measurement is performed at state SETUP
• Connection Disconnect phone : Disconnect phone.
• Connection Port setting : Show COM port setting dialog you can change port
number, baud rate etc.
• Connection Connect to Ag8960 : Connect to Agilent 8960.
• Connection Disconnect Ag8960 : Disconnect Agilent 8960.
• Option Settings Gpib state : Show current primary Gpib state.
• Option Settings MPL : Set max Tx power level used in APC procedure.
• Option Settings ➞ CL : Set cable loss value.
• Option- Settings ➞ Bin file : Set default binary file name.
Figure 12-2. Buttons and status bar
1. Connect to phone
2. Disconnect phone
3. Port setting
4. Connect to Ag8960
5. Disconnect Ag8960
6. AGC tab
7. APC tab
8 . Result window 9 . Band setting
10 . Sync. Button
(button 2 + button 1)
11. Start measure
12. Save result
13. Clear result window
14. Port connection state
15. Retry button
16. Ag8960 connection state
17. Informations.
18. Current state.